Go to page of
Similar user manuals
-
Boiler
IDEAL INDUSTRIES S24
4 pages 0.21 mb -
Automobile Accessories
IDEAL INDUSTRIES 61-322
19 pages 0.85 mb -
Garage Door Opener
IDEAL INDUSTRIES MX34
6 pages 3.41 mb -
Boiler
IDEAL INDUSTRIES HE24
60 pages 3.98 mb -
Boiler
IDEAL INDUSTRIES H CXSi 140
36 pages 3.45 mb -
Boiler
IDEAL INDUSTRIES C28
4 pages 0.19 mb -
Automobile Accessories
IDEAL INDUSTRIES S 00-S 10011
28 pages 4.25 mb -
Cooktop
IDEAL INDUSTRIES IZGS 68 ICTX
20 pages 1.68 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of IDEAL INDUSTRIES 61-310, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of IDEAL INDUSTRIES 61-310 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of IDEAL INDUSTRIES 61-310. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of IDEAL INDUSTRIES 61-310 should contain:
- informations concerning technical data of IDEAL INDUSTRIES 61-310
- name of the manufacturer and a year of construction of the IDEAL INDUSTRIES 61-310 item
- rules of operation, control and maintenance of the IDEAL INDUSTRIES 61-310 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of IDEAL INDUSTRIES 61-310 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of IDEAL INDUSTRIES 61-310, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the IDEAL INDUSTRIES service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of IDEAL INDUSTRIES 61-310.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the IDEAL INDUSTRIES 61-310 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-310 This Service Manual provides the following information: ● Precautions and safety information ● Specifications ● Basic maintenance (cleaning, replacing the battery and fuses) ● Performance test procedures ● Calibration and calibration adjustment procedures Form Number: TM61310 Revision:[...]
-
Page 2
Form Number TM61310 Rev 2 Aug 2007 T ABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 S pecifications 3 General S pecifications 3 Measurement Characteristics 4 V olt age S pecifications 4 Current S pecifications 4 Resistance S pecifications 5 Diode Check, Continuity , T emperature S pecifications 5 Auto P[...]
-
Page 3
Form Number TM61310 Rev 2 Aug 2007 Page 1 Introduction W arning T o av ures Th y . oid shock or injury , do not perform the verification test s or calibration proced described in the manual unless you are qualified to do so. e information provided in this document is for the use of qualified personnel onl Caution The 61-310 series cont ain part s t[...]
-
Page 4
Form Number TM61310 Rev 2 Aug 2007 Page 2 SAFETY Re uct or any For operating instructions, see the 61-310 Di git al Multimeter Instruction Manual. view the following safety precautions to av oid injury and prevent damage to this prod products connected to it. T o avoid potentia l hazards, use the produc t only as specified. CAUTION: These statement[...]
-
Page 5
Form Number TM61310 Rev 2 Aug 2007 All S ta ry ind Ge Page 3 SPECIFICA TIONS specifications are warranted unle ss noted typical and apply to the 61-310. ted accuracies are at 23°C±5°C at less than 70% relative humidity and without the batte icator displayed. neral specifications Characteristics Description Display count 3 ½ digit liquid crystal[...]
-
Page 6
Form Number TM61310 Rev 2 Aug 2007 Page 4 Me Ac (1) asurement Characteristics curacy is ±(% reading + number of digi ts) at 23°C ± 5°C, less than 80% R.H. DC V olts Range Resolution Accuracy Over v oltage protection 200.0mV 100 μ V 2.000V 1mV 20.00V 10mV 200.0V 100mV 0.5% + 2 600V 1V 0.8% + 2 600V rms Inp (2) ut Impedance: 10M Ω AC V olts Ra[...]
-
Page 7
Form Number TM61310 Rev 2 Aug 2007 Page 5 (4) Resist ance Range Resolution Accuracy Over v oltage protection 200.0 Ω * 1 0.1 Ω 0.8% + 4 2.000K Ω 1 Ω 20.00K Ω 10 Ω 200.0K Ω 100 Ω 2.000M Ω 1K Ω 0.8% + 2 20.00M Ω * 2 10K Ω 3.0% + 3 250V rms Op * 1 < (5) en circuit V oltage: -1.5V approx. 5 digit of reading rolling. * 2 ± 2%[...]
-
Page 8
Form Number TM61310 Rev 2 Aug 2007 Page 6 Physical and Env ironmental Characteristics Characteristics Description Dimensions (H×W×D) 150mm(H) ×76mm (W) ×38mm(D) (with holster) 5.9” (H) x 3.0”(W) x1.5”(D) Weight (with battery& holster) 0.219Kg (7.1 oz.) Environment al characteristics Description T emperature operating range 0 to +40°C[...]
-
Page 9
Form Number TM61310 Rev 2 Aug 2007 Page 7 Re Required equipm le B. If the recommended models are not available, equipment with equivalent specifications may be used. Repa performed only b T able E Characteristics ended Model quired Equipment ent is listed in T ab irs or servicing should be y qualified personnel. B. Required Equipment quipment Requi[...]
-
Page 10
Form Number TM61310 Rev 2 Aug 2007 Page 8 Basic Maintenance W arning avoid shock, remove the test leads and any input signals T o before opening the case or rep Op lacing the battery or fuses. ening the Meter Case Caution ircuit, alwa ys place the unco T o avoi onal short c vered met protec . Whe uit connect 1. Disconnect test lead ary switc d remo[...]
-
Page 11
Form Number TM61310 Rev 2 Aug 2007 Page 9 Replacing Fuses W arning To avoid electrical shock, remove the test leads and any input signals before replacing battery or fuses. the amage or injury, INSTALL ONLY quick a cting fuses with the following Amp/Volt F-310 Fuse: 250mA 250V FAST BLOW Fu 3. Remove the two screws under the battery cover . case unt[...]
-
Page 12
Form Number TM61310 Rev 2 Aug 2007 Page 10 Perf The following performance test acc Acc an operating temperature of 18°C to 28°C and a maximum of 80% relative humidity . T o perform the following tests, it is not necessary to open the case, no adjustments are nec the required connecti ons, apply the designated inputs, determine if the reading on t[...]
-
Page 13
Form Number TM61310 Rev 2 Aug 2007 Page 11 e Test: Table 2: AC Voltag Step Range Input Frequency Reading 1 200V 2.0V 60Hz 1.0 to 3.0 2 200V 2.0V 400Hz 1.0 to 3.0 3 200V 190.0V 60Hz 186.7 to 193.3 4 200V 190.0V 400Hz 186.7 to 193.3 5 600V 600V 60Hz 583.0 to 617.0 6 600V 600V 400Hz 583.0 to 617.0 T esting the DC milliamp 1 s 1-3 in T able 3. meter r [...]
-
Page 14
Form Number TM61310 Rev 2 Aug 2007 Page 12 T able 4: Resistance T est: Step Range Source Reading 1 *200 OHM 2.0 Ω 1.6 to 2.4 2 *200 OHM 190.0 Ω 188.3 to 191.7 3 2K OHM 1.900K 883 to 1 Ω 1. .917 4 20K OHM 19.00K 18.83 to 19.17 Ω 5 200K OHM 190.0K 188.3 to 191.7 Ω 7 20M OHM 19.00M 18.40 to 19.60 Ω *Lead resistance on the 200 ohm range[...]
-
Page 15
Form Number TM61310 Rev 2 Aug 2007 Page 13 Cali T o Recalibrate your meter: It is recommended that the Multimeter be ca ch year . 1. Perform calibration at an a rature of 23°C±2°C a nd a relative humidity of <70% Dis nect the te s and turn th ff. Rem s from the front terminals. 2. Position the meter face down. Remove the battery cover screws [...]