InFocus EC 10SB (SL) manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of InFocus EC 10SB (SL), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of InFocus EC 10SB (SL) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of InFocus EC 10SB (SL). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of InFocus EC 10SB (SL) should contain:
- informations concerning technical data of InFocus EC 10SB (SL)
- name of the manufacturer and a year of construction of the InFocus EC 10SB (SL) item
- rules of operation, control and maintenance of the InFocus EC 10SB (SL) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of InFocus EC 10SB (SL) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of InFocus EC 10SB (SL), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the InFocus service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of InFocus EC 10SB (SL).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the InFocus EC 10SB (SL) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    — 1 — EC 1 0SB (SL) EC 12 MODEL INSTRUCTION MANUAL AND SAFETY INSTRUCTIONS FOR AIR COMPRESSOR EC 10SB(SL) EC 12 W ARNING Improper and unsafe use of this compressor can result in death or serious bodily injury! This manual contains important information about product safety. Please read and understand this manual before operating the compressor.[...]

  • Page 2

    — 2 — — CONTENTS — Page IMPORTANT INFORMATION ............................... 2 MEANINGS OF SIGNAL WORDS ........................ 2 SAFETY IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR ........ 3 REPLACEMENT PARTS ........................................ 5 GROUNDING INSTRUCTIONS ............................ 5 EXTENSION CORD ......[...]

  • Page 3

    — 3 — SAFET Y IMPOR T ANT SAFETY INS TRUCTIONS FOR USE OF THE COMPRESSOR W ARNING: Death or serious bodily injury could result from improper or unsafe use of compressor. To avoid these risks, follow these basic safety instructions: READ ALL INSTRUCTIONS 1. NEVER TOUCH MOVING PARTS. Never place your hands, fingers or other body parts near the co[...]

  • Page 4

    — 4 — 16. CHECK DAMAGED PARTS AND AIR LEAK. Before further use of the compressor, a guard or other part is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions[...]

  • Page 5

    — 5 — 33. THE SAFETY VALVE MUST WORK PROPERLY. Risk of bursting. Before starting the compressor pull the ring on the safety valve to make sure the valve moves freely. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. GROUNDING INS TRUCTIONS This compressor should be grounded whi[...]

  • Page 6

    — 6 — EXTENSION CORD Use only three-wire extension cords that have three-prong grounding-type plugs and three-pole receptacles that accept the compressor’s plug. Replace or repair damaged cord. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product wi[...]

  • Page 7

    — 7 — OPERA TION AND MAINTENANCE NOTE : The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor. NAME OF P ARTS Pressure gauge (B) indicates t[...]

  • Page 8

    — 8 — PRIOR T O OPERA TION 1. Power source Ensure that the power source to be utilized conforms to the power source requirements specified on the product nameplate. 2. Power switch Ensure that the knob of the pressure switch is in the “OFF” position (Fig. 2). If the plug is connected to a receptacle while the knob is in the “ON” positio[...]

  • Page 9

    — 9 — 4. Confirm the power receptacle If the power receptacle only loosely accepts the plug, the receptacle must be repaired. Contact the nearest electric store for repair service. If such a faulty receptacle is used, may cause overheating, resulting in a serious hazard. 5. Dipstick insertion and oil level check (If your compressor is EC10SB(SL[...]

  • Page 10

    — 10 — Fig. 5 3. Shutdown ( 1 ) Push the knob of the pressure switch to “ O FF ” ( Refer to Fig. 1 and Fig. 2) . (2) Unplug the plug from power source. (3) Open the drain cock located at the lower part of the tank (Fig. 6). MAINTENANCE W ARNING: Disconnect the compressor from the power source and remove the compressed air from the air tank [...]

  • Page 11

    — 11 — Fig. 8 Pour oil into the hole of the dipstick. To the level indicated on the dipstick (Refer to Fig. 4). For oil replacement, follow the table below. OIL TYPE SAE 5W50 SYNTHETIC OIL (–20°+120°F) For both summer and winter use SAE 10W40 MULTI-GRADED OIL (+50° + 120°F) For warm weather use only (2) Check the oil level of the pumping [...]

  • Page 12

    — 12 —[...]

  • Page 13

    — 13 — Item No. Code No. P ar t Name Q’ty Ref erence No. 1 Joint 1 7084080000 2 Screw 4 7011220000 3 Screw 1 7014300000 4 Washer 1 7030780000 5 Head 1 7570550000 6 Filter plate 1 7458340000 7 Intake filter 1 4085010000 8 Screw 1 7012010000 9 Set of gaskets 1 4085100000 10 Monoplate 1 4200020000 11 Conrod-cylinder kit 1 4190350000 12 Bearing 1[...]

  • Page 14

    — 14 —[...]

  • Page 15

    — 15 — Item No. Code No. P ar t Name Q ’ ty Ref erence No. 1 Screw 1 7012010000 2 Intake filter 1 7210430000 3 Filtering element 1 7210010000 4 Filter plate 1 7458340000 5 Joint 1 7084190000 6 Set of gaskets 1 4082200000 7 Cylider 1 7575070000 8 Piston rings 1 4080020000 9 Piston pin 1 7050020000 10 Ring 2 7041010000 11 Con rod 1 5150150008 1[...]

  • Page 16

    — 16 —[...]

  • Page 17

    — 17 —[...]

  • Page 18

    312 Code No. C99128411 Printed in Italy Hitachi Koki Co., Ltd.[...]