Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PD10P-X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PD10P-X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PD10P-X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ingersoll-Rand PD10P-X should contain:
- informations concerning technical data of Ingersoll-Rand PD10P-X
- name of the manufacturer and a year of construction of the Ingersoll-Rand PD10P-X item
- rules of operation, control and maintenance of the Ingersoll-Rand PD10P-X item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PD10P-X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PD10P-X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PD10P-X.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PD10P-X item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET – BRYAN, OHIO 43506 (800) 276-4658 y F AX (800) 266-7016 © 2010 CCN 15206378 OPERA T OR’ S MANU AL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11 -1 0 -0 3 REVISED: 8 -1 3 -10 (REV . 1 2 ) 1” DIAPHRA GM PUMP 1:1 RA TIO (NON-MET ALLIC) READ THIS MANUAL CAREFULL Y BEFORE[...]
-
Page 2
Page 2 of 8 PD10P-X EXCESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pressure as stated on the pump model plate . Be sure material hoses and other componen ts are able to withstand fluid p[...]
-
Page 3
PD10P-X Page 3 of 8 GENERAL DESCRIPTION The ARO diaphragm pump o ers high volume delivery even at low air pressur e and a broad range of material compatibility options available. Ref er to the model and option char t. ARO pumps feature stall r esistant design, modular air motor / uid sections. Air operated double diaphragm pumps utilize a pr[...]
-
Page 4
Page 4 of 8 PD10P-X FL UID SECTION SERVICE KITS (637396-X X) KITS INCL UDE: BALLS (see Ball Option, refer to -XX in Service Kit chart below), DIAPHRAGMS (see Diaphragm Option, r efer to -X X in Service Kit char t below), and items 19, 33, 70, 144, 175 and 180 (listed below) plus 174 and 94276 Lubripla te FML -2 greas e (page 6). SEA T OPTIONS P[...]
-
Page 5
PD10P-X Page 5 of 8 15 FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 131 175 Figure 2 29 144 70 22 21 19 26 22 19 21 144 70 69 180 5 7 6 27 68 175 60 (models PX10P-F XS-XXX) 60 (models PX10P-AXS-XXX and PX10P-BXS-XXX) 26 33 33 195 76 74 A A Santoprene 8 7 PTFE VIEW OF TWO PIECE PTFE DIAPHRAGM 180 28 AUXILIAR Y VIEW A-A 60 (models PX10P-YXS-XXX) 61[...]
-
Page 6
Page 6 of 8 PD10P-X P ARTS LIST / PD10P -X -X AIR SECTION AIR MO TOR SECTION SERVICE Ser vice is divided into tw o par ts − 1. Pilot V alve, 2. Major Valv e. GENERAL REASSEMBL Y NOTES: Air Motor Section S ervice is continued from Fluid Section repair . Inspect and replace old par ts with new par ts as necessary. L ook for deep scratches on surfac[...]
-
Page 7
PD10P-X Page 7 of 8 168 111 TORQUE REQUIREMENTS NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL FASTENERS ARE METRIC. T orque (105 and 134) screw to 35 - 40 in. lbs (4.0 - 4.5 Nm). LUBRICA TION / SEALANTS Apply anti-seize compound to threads at assembly . Apply Lubriplate FML-2 grease to “O" rings, “U" Cups & mating parts. 139 138 134 13[...]
-
Page 8
Page 8 of 8 PD10P-X PN 97999-1061 DIMENSIONAL DA T A (Dimensions shown are for reference only , they are displayed in inches and millimeters (mm). A - see below B - 13-25/32" (349.8 mm) C - 10-1/16" (255.3 mm) D - 2-11/32" (59.4 mm) E - 11-1/32" (279.5 mm) F - 8-5/16" (211.1 mm) G - see below H - 5-1/32" (127.6 mm) J -[...]