Go to page of
Similar user manuals
-
Septic System
Ingersoll-Rand ARO 670036-15X
1 pages 0.04 mb -
Septic System
Ingersoll-Rand 612035
2 pages 1.81 mb -
Septic System
Ingersoll-Rand DAB05-XXXX-X-X
4 pages 0.43 mb -
Septic System
Ingersoll-Rand 6696X-X
4 pages 0.13 mb -
Septic System
Ingersoll-Rand 67072
4 pages 0.42 mb -
Septic System
Ingersoll-Rand 650639-XXX
2 pages 0.17 mb -
Septic System
Ingersoll-Rand NM2202A-X
2 pages 0.12 mb -
Septic System
Ingersoll-Rand PD30X-XXX-XXX-C
8 pages 0.72 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PF20R-X-B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PF20R-X-B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PF20R-X-B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ingersoll-Rand PF20R-X-B should contain:
- informations concerning technical data of Ingersoll-Rand PF20R-X-B
- name of the manufacturer and a year of construction of the Ingersoll-Rand PF20R-X-B item
- rules of operation, control and maintenance of the Ingersoll-Rand PF20R-X-B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PF20R-X-B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PF20R-X-B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PF20R-X-B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PF20R-X-B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CCN 15227671 D INGERSOLL RAND COMP ANY 209 NORTH MAIN STREET - BRY AN, OHIO 43506 OPERA T OR’S MANUAL P F 2 0 R -X -B RELEASED: 12-14-04 REVISED: 9 - 15-11 (REV . 0 4 ) INCLUDING: OPERA TION, INST ALLA TION & MAINTENANCE 2” DIAPHRAGM PUMP 1:1 RA TIO FLAP V AL VE (MET ALLIC) READ THIS MANUAL CAREFULL Y BEFORE INST ALLING, OPERA TING OR S[...]
-
Page 2
PF 20R -X-B Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE. Can cause person - al injury , pump damage or property damage. S Do not exceed the maximum inle[...]
-
Page 3
Page 3 of 8 PF 20R -X-B GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections. Air operated double diaphragm pumps utilize a pressu[...]
-
Page 4
MA TERIAL CODE [B] = Nitrile [C] = Carbon Steel [Co] = Copper [CI] = Cast Iron [E] = E.P .R. [SP] = Sant oprene [SS] = Stainless Steel [T] = PTFE [U] = Polyurethane [V] = Viton V “Smart Parts” keep these items on hand in addition t o the service kits for fast repai r and reduction of down time. n Air Motor Kit Parts, see page 6. PF 20R -X-B Pag[...]
-
Page 5
Page 5 of 8 PF 20 R -X -B P ARTS LIST / PF20X -X-X-B FLUID SECTION 1 k 26 ,G FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 COLOR CODE DIAPHRAGM FLAP BUMPER MA TERIAL COLOR COLOR COLOR E.P .R. - - Blue ( S )B l u e ( S ) Nitrile Black Red ( S )R e d ( S ) Santoprene T an - - - - Santoprene Green - - - - (Backup) PTFE White - - - - Urethane - - Red [...]
-
Page 6
PF 20 R -X -B Page 6 of 8 P AR T S L I ST / P F 2 0 X -X -X -B A IR S E C T I ON n Indicates parts included in 637369 Air Section Service Kit s hown below and items (70), (144), (175), (180) shown on page 4. AIR MOTOR P ARTS Item Description (size) Qty Part No. [Mtl] Item Description (size) Qty Part No. [Mtl] 101 Center Body (1) 95667 [P] 103 Bushi[...]
-
Page 7
Page 7 of 8 PF 20 R -X -B P AR T S L I ST / P F 2 0 X -X -X -B A IR S E C T I ON 168 k 107 107 . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. T orque (105) Screw to 35 - 40 in. lbs (4. 0 - 4.5 Nm). T orque (134) Screw to 35 - 40 in. lbs (4. 0 - 4.5 Nm). LUBRICA TION / SEALANTS k Apply Lubriplate FML- 2 greas[...]
-
Page 8
PF 20 R -X -B Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of (14) diaphragm screw . Air bubbles in product discharge. S Check connections of suction plumbing. S Check gaskets between intake manifold and inlet side fluid caps. S Check tightness of (14) diaphragm screw . Motor [...]