Go to page of
Similar user manuals
-
Water Pump
Ingersoll-Rand NM2304B-X-X
2 pages 0.19 mb -
Water Pump
Ingersoll-Rand PD30X-X
8 pages 0.39 mb -
Water Pump
Ingersoll-Rand 6544X-X
8 pages 0.59 mb -
Water Pump
Ingersoll-Rand 6546X-X
8 pages 0.59 mb -
Water Pump
Ingersoll-Rand NM2328A-X
2 pages 0.1 mb -
Water Pump
Ingersoll-Rand CHOP-CHECK 650941-X-C
2 pages 0.16 mb -
Water Pump
Ingersoll-Rand 650770-X-B
1 pages 0.06 mb -
Water Pump
Ingersoll-Rand LM2305A-X-B
4 pages 0.2 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PH10A-X-X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PH10A-X-X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PH10A-X-X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ingersoll-Rand PH10A-X-X should contain:
- informations concerning technical data of Ingersoll-Rand PH10A-X-X
- name of the manufacturer and a year of construction of the Ingersoll-Rand PH10A-X-X item
- rules of operation, control and maintenance of the Ingersoll-Rand PH10A-X-X item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PH10A-X-X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PH10A-X-X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PH10A-X-X.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PH10A-X-X item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
E 2010 CCN 99755480 (800) 276-4658 D F AX (800) 266-7016 INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET - - BRY AN, OHIO 43506 OPERA T OR’S MANUAL P H 1 0 A -X -X RE LE ASE D: 7 -7 -00 REVISED: 10-15-10 (REV . M ) INCLUDING: OPERA TION, INST ALLA TION & SER VICE 1” HIGH PRESSURE DIAPHRAGM PUMP 3:1 RA TIO (MET ALLIC) READ THIS MANUAL[...]
-
Page 2
PH10A-XXX-XXX (en) Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE INLET AIR PRESSURE ST A TIC SPARK EXPLOSION HAZARD HAZARDOUS MA TERIALS HAZARDOUS PRESSURE INJECTION HAZARD W ARNING EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or proper[...]
-
Page 3
Page 3 of 8 PH10A-XXX-XXX (en) GENERAL DESCRIPTION The 1” metallic diaphragm pump offers high volume delivery even at low air pressures, easy self priming, the ability to pump various viscosity ma- terials and the ability to pass solids (as stated in the chart above). The pump is offered with optional wetted parts configurations to satisfy a va- [...]
-
Page 4
PH10A-XXX-XXX (en) Page 4 of 8 P ARTS LIST / PH10A -XXX-XXX FLUID SECTION FLUID SECTION P ARTS Item Description (size) Qty Part No. [Mtl] L Fluid Section Service Kit 637339-( ) V 1 Rod (1) 98724-1 [C] n 2 “O” Ring (3/32” x 3/4” o.d.) (1) Y330-1 13 [B] L 3 “O” Ring (3/32” x 11/16” o.d.) (4) Y328-1 12 [T] V 5 Plate (2) 94074-1 [C] V 6[...]
-
Page 5
Page 5 of 8 PH10A-XXX-XXX (en) P ARTS LIST / PH10A -XXX-XXX FLUID SECTION . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. (14) Bolt, 49 - 52 ft lbs (66.4 - 70.5 Nm). (26) Bolts, 120 - 140 in. lbs (13.6 - 15.8 Nm). (29) Flange nuts, 280 - 300 in. lbs (31.6 - 33.9 Nm) tighten alternately and evenly . LUBRICA TION / SEALANTS j Apply Key-L[...]
-
Page 6
PH10A-XXX-XXX (en) Page 6 of 8 P ARTS LIST / PH10A -XXX-XXX AIR MOT OR SECTION n Indicates parts included in 637338 Air Section Repair Kit. Item Description (size) Qty Part No. Mtl Item Description (size) Qty Part No. Mtl 101 Motor Center Body (1) 95122 -1 [A] n 102 “O” Ring (1/16” x 1” o.d.) (2) Y325-20 [B] V 103 Sleeve (1) 94527 [D] 104 P[...]
-
Page 7
Page 7 of 8 PH10A-XXX-XXX (en) P ARTS LIST / PH10A -XXX-XXX AIR MOT OR SECTION Figure 3 127 201 l 126 109 j 111 102 jm 103 11 8 137 j 136 109 121 MAJOR V AL VE See cross section detail figure 4. PILOT VA L VE MAJOR V AL VE CROSS SECTION DET AIL 11 0 j 104 123 k j 11 0 11 2 j 11 4 j 11 3 11 5 11 6 11 2 j 11 3 j 11 4 11 5 11 6 j 111 j 137 Figure 4 10[...]
-
Page 8
PH10A-XXX-XXX (en) Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of bolt (14). Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and fluid caps. S Check tightness of bolt (14). Pump blows air out main exhaus[...]