Go to page of
Similar user manuals
-
Computer Hardware
Intel XP-P41533E
26 pages 1.09 mb -
Computer Hardware
Intel Intel NetStructure MPCHC5525 System Master Processor Board IPMI Reference Driver
32 pages 0.38 mb -
Computer Hardware
Intel IMB200
77 pages 2.11 mb -
Computer Hardware
Intel I-45CV
24 pages 1.08 mb -
Computer Hardware
Intel D955XCS
74 pages 2.88 mb -
Computer Hardware
Intel MB890
66 pages 0.84 mb -
Computer Hardware
Intel 8XC251SP
20 pages 0.55 mb -
Computer Hardware
Intel AIMB-253
62 pages 2.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Intel MFSYS25, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Intel MFSYS25 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Intel MFSYS25. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Intel MFSYS25 should contain:
- informations concerning technical data of Intel MFSYS25
- name of the manufacturer and a year of construction of the Intel MFSYS25 item
- rules of operation, control and maintenance of the Intel MFSYS25 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Intel MFSYS25 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Intel MFSYS25, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Intel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Intel MFSYS25.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Intel MFSYS25 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Intel ® Modular Server System MFSYS25, Intel ® Modular Server System MFSYS35, Intel ® Compute Module MFS5000SI T ested Hardware and Operating System List Revision 1.9 March, 2009 Enterprise Platforms and Services Division[...]
-
Page 2
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Revision History Date Revision Number Modifications November, 2007 1.0 Initial Release January, 2008 1.1 Added support for Windows 2003 Se rver, clarified Virtualization Softw are testing/certific ation details January 22 , 2008 1.2 Adde[...]
-
Page 3
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Revision 1.9 iii Disclaimers THE INFORMATION IN THIS DOCUMENT IS PROVID ED "AS IS" WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, FI TNESS FOR ANY PART ICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISIN[...]
-
Page 4
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Table of Contents 1. Introduction ................................................................................................................... ....... 6 1.1 Test Overview ...........................................................[...]
-
Page 5
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI List of Tables Table 2.1 Base System Configurations Tested ............................................................................. 9 Table 3.1 Operating Systems Tested ...............................................................[...]
-
Page 6
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 1. Introduction This document is intended to provide users of the Intel® Modular Server System MFSYS25/MFSYS35 and Intel® Compute Module MFS5000SI with a guide to the different operating systems, expansion cards, and peripherals Intel [...]
-
Page 7
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI • Intel will NOT provide support for issues related to use of any 3 rd party expansion cards or peripherals installed in the server sy stem when an operating system that received basic installation testing only is in use. • Support i[...]
-
Page 8
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI • Intel will enable vendors to provide driver support for I/O Expansion Cards using these operating systems. • Intel will go through some of the steps to achieve certification to ensure its customers do not run across any problems, b[...]
-
Page 9
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 2. MFS5000SI / MFSYS25 / MFSYS35 Base System Configurations The following table lists the base system configurati ons tested. Base system configurations will change as new revisions of the Intel® Compute Module MFS5000SI or the Intel® [...]
-
Page 10
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 3. Supported Operating Systems & Sof tware The following table provides a list of the operating systems and software applications that Intel plans to test with the Intel® Compute Module MFS5000SI. Each of the listed operating system[...]
-
Page 11
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Operating System Type of Test ing Notes SuSE Linux Enterprise Server 10 U1 (32-bit), Configuration 1 - Basic Installation, Compatibiltiy Only SuSE Linux Enterprise Server 10 U1 (64-bit), Configuration 1 - Compatibility & Stress SCO U[...]
-
Page 12
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 3.1 Operating System Certifications Listed below are the operating systems that Intel plans to certify with the Intel® Compute Module MFS5000SI. However, the customer is responsible for their own certification from the individual operat[...]
-
Page 13
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 3.2 Operating System Storage Component Support Table 3.3 Operating System Storage Component Support Operating System Single SCM Dual SCM Shared LUN Single SCM Shared LUN Dual SCM Microsoft Windows* 2003 Enterprise (32-bit), R2 SP2 Suppor[...]
-
Page 14
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 4. I/O Exp ansion Cards & Peripherals I/O Expansion card and peripheral compatibility and stress testing will only be performed with the latest version of an operating system at the time the validation testing occurred. The following[...]
-
Page 15
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Table 4.1 Intel® Compute Module MFS5000SI Supported Items Manufacturer Model Name Model Number Interface Microsoft Windows* 2003 Enterprise (32- bit, 64-bit), SP2 Microsoft Windows 2008 Enterprise (32- bit, 64-bit) Red Hat Enterprise Li[...]
-
Page 16
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Manufacturer Model Name Model Number Interface Microsoft Windows* 2003 Enterprise (32- bit, 64-bit), SP2 Microsoft Windows 2008 Enterprise (32- bit, 64-bit) Red Hat Enterprise Linux AS 5.0 U1 (32- bit, 64-bit) SuSE Linux Enterprise Serve[...]
-
Page 17
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Table 4.2 Intel® Modular Server Sy stem MFSYS25 Supported Peripherals Manufacturer Model Name Model Number Interface Microsoft Windows* 2003 Enterprise (32- bit, 64-bit), SP2 Microsoft Windows 2008 Enterprise (32- bit, 64-bit) Red Hat E[...]
-
Page 18
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 5. Hard Disk Drives The hard drives listed in the following table have been tested with the Intel® Modular Server System MFSYS25 / MFSYS35 by Intel validation l abs and/or by individual drive vendors. The following operating system iden[...]
-
Page 19
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI Number (i.e. 1) This hard drive has been tested and is supported under the operating system identified by the operating sy stem identification number. remain the property of the IHV (Intel cannot provide copies of these reports). Table 5[...]
-
Page 20
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 6. Inst allation Guidelines 6.1 Slipstreamed install for Windows 2003 Enterprise Edition (32 & 64 bit) Method for performing Slipstreamed install for Windows 2003 Installation via CD-ROM drive. Both the CD-ROM and Floppy can not be s[...]
-
Page 21
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 6.2 Windows 2003 Enterprise Edition (32 & 64 bit) Remote Installation Method Method for performing Remote Windows 2003 Installation via CD-ROM drive. Guideline: Note: Prepare a Slipstreamed CD per section 6.1. 1. Plug your slipstream[...]
-
Page 22
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 10. Confirm all your settings then Hit Apply. Hit OK when the confirmation dialog is displayed. 11. With the mouse, select the Chassis Front Tab. 12. Click on Server 1 on the Chassis picture with the Mouse. 13. Click on the Remote KVM &a[...]
-
Page 23
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 15. Choose the Device Menu Option and then click on the CDROM check box. 16. Choose the Redirect CDROM drive to select the CDROM on your system as the device to load the operating system from. 17. Choose the drive letter of the CDROM to [...]
-
Page 24
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 18. Return to the Modular Server screen and select the Chassis Front TAB. Do not close out the KVM screen. 19. Select Server 1 and then hit the Power On option under “Server 1” Actions. 20. Select OK when requested to power on Server[...]
-
Page 25
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 6.3 Red Hat Enterprise Linux 5.0 (32 & 64 bit) Remote Installation Method Method for performing Remote Red Hat Enterprise Linux 5.0 Installation with DVD media via FTP Guideline: Configure the MFSYS25 system as follows: 1. Ensure P2.[...]
-
Page 26
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 12. From Filezilla server session click “Shared Folders”, then click “Add”, navigate down and select the client’s DVD’s unit drive-letter, in the example case below it was E, then click OK . 13. To verify your FTP setup is co[...]
-
Page 27
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI User: anonymous Password: (just hit enter key) ftp> dir 14. You should see the whole directory tree of the RHEL-5 DVD media you are trying to install from 15. The Filezilla FTP server is now setup and ready to use 16. Log in CMM-GUI 1[...]
-
Page 28
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI or hit F2 then type same command there. Revision 1.9 28[...]
-
Page 29
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 22. When asked for Installation Method - Select FTP then click OK 23. When asked for Networking Device - Select (hi-lite) eth0 as your main interface then click OK (Use TAB key to move around) 24. When presented dialog Configure TCP/IP -[...]
-
Page 30
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 26. Select DHCP mode when asked for network configuration for Eth0 and Eth1 Revision 1.9 30[...]
-
Page 31
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 6.4 SuSE Linux Enterprise Server 10 (32 & 64 bit) Remote Installation Method Method for performing SuSE Linux Enterprise Server 10 Installation via SMB Guideline: Configure the MFSYS25 system as follows: 1. Ensure P2.0.5 or later SW [...]
-
Page 32
Intel® Modular Server Sy stem MFSYS25, Intel® Modular Server Sy stem MFSYS35, Intel® Compute Module MFS5000SI 10. When server boots to the option table, use down-arrow key to select second option from the given list “Installation” then type (Boot Options line): install=smb://x.x.x.x/drive-letter where: x.x.x.x : your client’s IP drive-lett[...]