Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Intel SE7501CW2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Intel SE7501CW2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Intel SE7501CW2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Intel SE7501CW2 should contain:
- informations concerning technical data of Intel SE7501CW2
- name of the manufacturer and a year of construction of the Intel SE7501CW2 item
- rules of operation, control and maintenance of the Intel SE7501CW2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Intel SE7501CW2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Intel SE7501CW2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Intel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Intel SE7501CW2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Intel SE7501CW2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Server Inst allation and Integration Guide Using the Boxed Intel ® Xeon Processor and Boxed Intel ® Server Board SE7501CW2[...]
-
Page 2
Intel Server Board SE7501CW2 Installation and Integration Guide Revision History Date Revision Notes Product Code 9/25/03 1 First Draft 10/6/03 2 Second Draft Disclaimers The information contained in th is document is provided for informational purposes only and represents the current view of Intel C orporation (“Inte l”) and its contrib utors [...]
-
Page 3
Intel Server Board SE7501CW2 Installa tion and Integration Guide Table of Contents Introduction ......................................................................................5 Document Ov erview ................................................................................ 5 Target Audience ................................................[...]
-
Page 4
Intel Server Board SE7501CW2 Installation and Integration Guide Making Optional Connections to the Server Board ................................. 17 Installing the Seri al B Cable .................................................................. 18 Cable Routing – Intel Se rver Chassis SC5200 ........................................ 19 IDE or SC[...]
-
Page 5
Intel Server Board SE7501CW2 Installa tion and Integration Guide Introduction Document Overview This guide outlin es the procedures for integratin g an Intel ® Server Platform using an Inte l Server Board SE7501CW2 and Intel Xeon processors. This guide consists of the most essential inf ormation first-time server builder s need to successfully[...]
-
Page 6
Intel Server Board SE7501CW2 Installation and Integration Guide Troubleshooting Guide In the unlikely event yo u do encounter issues, the troubleshooting gu ide will help you troubleshoot and identify possible areas of concern regarding the Intel Server Board SE7501CW2. It will also assist you in collectin g the data needed to help you work through[...]
-
Page 7
Intel Server Board SE7501CW2 Installa tion and Integration Guide Hardware Integration The following in stallation procedures enable y ou to prepare a chassis for integration, add the needed components to your server board, and install the server board. The procedures are condensed from the more comprehensive and detailed Product Guides for the Inte[...]
-
Page 8
Intel Server Board SE7501CW2 Installation and Integration Guide Important Safety Information Safety Instructions and Information To avoid personal injury or property dama ge, the following safety instructions apply whenever working in side the chassis: 1. Turn off all peripheral device s connected to this product. 2. Turn off the system by pressing[...]
-
Page 9
Intel Server Board SE7501CW2 Installa tion and Integration Guide Chassis Preparation and Server Board Installation About the I/O Shield An ATX 2.03-compliant I/O shield is provided wi th your server board. The shield is required by Electromagnetic Interference (EMI) regul ation s. I t minimizes EMI and helps obtain proper cooling of the server. The[...]
-
Page 10
Intel Server Board SE7501CW2 Installation and Integration Guide Installing Chassis Standoffs If your chassis does not have stando ffs placed as shown, you must rearrange them so t hey match the hol es in the server board. Failure to properly rearrange the metal standoffs may cause the server board to malfunc tion and permanently damage it. Your ch [...]
-
Page 11
Intel Server Board SE7501CW2 Installa tion and Integration Guide Installing Memory The server board supports only DDR266- compliant DIMMs. The minimum supported memory configuration is 128 MB, using one 128-MB DIMM. The maximum configurable memory size is 8 GB using 4 2-GB DIMMs. If a single DIMM is used, you must install it in the DIMM 1A socket. [...]
-
Page 12
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Boxed Intel Xeon Processor Choosing the Processor Socket Use these instruction s for installing you r processor instead of the instruction s that came with your boxed processor. • If only ONE processor is to be used, it must be in stalled in the processor socke[...]
-
Page 13
Intel Server Board SE7501CW2 Installa tion and Integration Guide Installing the Retention Mechanism 1. Insert the retention brackets. 2. Tighten the four retention screws. Applying Thermal Grease Apply thermal grease to the processor as shown. Attaching the Heat Sink and Retention Clips 1. Place the heat sink onto the processor as shown. Heat sink [...]
-
Page 14
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Processor Wind Tunnel The following in structions apply to the base Intel Server Chassis SC5200 an d reference chassis installations. Di rect the airflow from the processor wind tunnel toward the rear of the chassis as shown. Attaching the Heat Sink Fan Install the proce[...]
-
Page 15
Intel Server Board SE7501CW2 Installa tion and Integration Guide Attaching the Wind Tunnel 1. Spread the tabs outward sli ghtly (1a). Lower the wi nd tunnel assembly onto the retention mechani sm (1b). 2. The tabs on the fan assembly (2a) slide into slot s (2b) on the inner side of t 3. The tabs on fan surface of the retent 4. Attach the fa board C[...]
-
Page 16
Intel Server Board SE7501CW2 Installation and Integration Guide Making Required Connections to the Server Board Make these connections regardless of the chassi s used. Refer to your chassis documentation r Chassis SC5200 Base or Red to the system fan 3 and 4 Note: then they will run at a faster rate to compensate for what the sy stem interprets as [...]
-
Page 17
Intel Server Board SE7501CW2 Installa tion and Integration Guide Making Optional Connections to the Server Board These connections are required only when th e corresponding component is installed. A Hot Swap Back Plane (HSBP) B System Fan 5 C Front Universal Se rial Bus D Serial B 17[...]
-
Page 18
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Serial B Cable For the Intel Server Chassis SC5200, yo u can connect the Serial Port B cable to either th e back of the chassis or, on a rack-mount system, to the front of the chassis. 1. 2. back pa shown. 3. Attach the the Server Use a screwdriver to remove the connecto[...]
-
Page 19
Intel Server Board SE7501CW2 Installa tion and Integration Guide Cable Routing – Intel Server Chassis SC5200 routing guidelines below. sys 1. bles as shown. Floppy and Front Panel Cables Route the floppy drive and front panel cables as shown. Installing the Access Cover 1. Place the cover so the tabs go into the slots on the server. The cover sho[...]
-
Page 20
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Chassis Feet (Pedestal Mode) 1. If you are installing t his server into a rack syst em, skip these steps and go to “Installing in to a Rack (Rack kbench. assis. The th only one set of holes in oot, the middle hole should face toward the front of the chassis. Hole locat[...]
-
Page 21
Intel Server Board SE7501CW2 Installa tion and Integration Guide Finishing Up WARNING tall the chassis access cover before finishing ver” on page 19). An Ins up (see ”Installing the Access Co electrical shock hazar d exists if the chassis access cover is wer. bles as shown. to the back panel and to an A C outlet as shown. Note: Intel Server Cha[...]
-
Page 22
Intel Server Board SE7501CW2 Installation and Integration Guide Software Installation Updating the BIOS Intel highly recommends tha t you go to th e Intel Server Board SE7501CW2 supp ort Web ite and download and install the latest syste m BIOS update for your operating system. The Intel Server Board SE7501CW2 support Web site is: http://suppo E7501[...]
-
Page 23
Intel Server Board SE7501CW2 Installa tion and Integration Guide LANDesk* Client Manager ma nage a computer an d troubleshoot common computer problems. Use Client Mana ger to: nt computers (single, • Client: The client version enables an en d user to view informat ion and manage alerts for a local computer. This v ersion doesn't permit a use[...]
-
Page 24
Intel Server Board SE7501CW2 Installation and Integration Guide Intel Server Maintenance and Reference Training Tool CD enance and Reference Traini ng Tool CD (Intel SMaRT Tool ) is an providing support in formation to assist with th e maintenance and repair of Intel processor-based server sy stems and accessories. The Intel SMaRT T ool fea e truct[...]
-
Page 25
Intel Server Board SE7501CW2 Installa tion and Integration Guide Thank you for purchasing Intel products! For additional integration reso urces, please visit www.support.intel.com . 25[...]