Jackson TEMPSTAR HH GPX manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Jackson TEMPSTAR HH GPX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Jackson TEMPSTAR HH GPX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Jackson TEMPSTAR HH GPX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Jackson TEMPSTAR HH GPX should contain:
- informations concerning technical data of Jackson TEMPSTAR HH GPX
- name of the manufacturer and a year of construction of the Jackson TEMPSTAR HH GPX item
- rules of operation, control and maintenance of the Jackson TEMPSTAR HH GPX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Jackson TEMPSTAR HH GPX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Jackson TEMPSTAR HH GPX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Jackson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Jackson TEMPSTAR HH GPX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Jackson TEMPSTAR HH GPX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL MANUAL INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS FOR JACKSON MODELS: TEMPSTAR GPX TEMPSTAR HH GPX Jackson MSC, INC. P.O. BOX 1060 HWY. 25E BARBOURVILLE, KY. 40906 FAX (606) 523-9196 PHONE (606) 523-9795 www.jacksonmsc.com DUAL TEMPERATURE, GAS HEATED, DOOR-TYPE DISHMACHINES August 6 , 200 7 P/N 7610-002-57-32 [...]

  • Page 2

    [...]

  • Page 3

    i REVISION/ P AGE REVISION DA TE MADE BY APPLICABLE ECN DET AILS C 06-08-04 MA W 7006 Changed thermostat bracket from 17372 to 18164. Changed to new layout. D 07-24-06 MA W 7445, 7553 7571 Converted to centered layout. Replace 05700-002-63-16 with 04730-207-15-00 nipple. Add false panel assembly and wash thermostat kit s. 3 08-06-07 MA W PROCESS Co[...]

  • Page 4

    ii NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL TEMPSTAR HH GPX TEMPSTAR GPX = Gas heated, hot water sanitizing, door-type dishmachine TEMPSTAR HH GPX = Gas heated, hot water sanitizing, door-type dishmachine with higher hood Model: Serial No.: Installation Date: Service Rep. Name: Phone No.:[...]

  • Page 5

    Section Description Page I. SPECIFICATION INFORMATION Specifications of the Tempstar GPX 2 Specifications of the Tempstar HH GPX 3 Dimensions for the Tempstar GPX 4 Dimensions for the Tempstar HH GPX 5 Table Dimensions 6 II. INSTALLATION/OPERATION INSTRUCTIONS Installation Instructions 8 Electrical Installation Instructions 9 Gas Booster Heater Con[...]

  • Page 6

    1 SECTION 1: SPECIFICATION INFORMATION[...]

  • Page 7

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 1: SPECIFICATION INFORMATION SPECIFICATIONS OF THE TEMPSTAR GPX 2 PERFORMANCE/CAPABILITIES OPERATING CAPACITY (RACKS/HOUR) RACKS PER HOUR 57 DISHES PER HOUR 1425 GLASSES PER HOUR 1425 OPERATING CYCLE (SECONDS) WASH TIME 45 RINSE TIME 11 DWELL TIME 2 TOTAL[...]

  • Page 8

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: 08-06-2007 SECTION 1: SPECIFICATION INFORMATION SPECIFICATIONS OF THE TEMPSTAR HH GPX 3 PERFORMANCE/CAPABILITIES OPERATING CAPACITY (RACKS/HOUR) RACKS PER HOUR 53 DISHES PER HOUR 1325 GLASSES PER HOUR 1325 OPERATING CYCLE (SECONDS) SELECTION (A) WASH TIME 45 RINSE TI[...]

  • Page 9

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 1: SPECIFICATION INFORMATION DIMENSIONS FOR TEMPSTAR GPX A - DRAIN 1 1/2” NPT B - WATER INLET 1/2” NPT C - ELECTRICAL CONNECTION D - STANDARD WALL CLEARANCE WITH DISHTABLE 4” E - OUTLET TO BOOSTER HEATER 3/4” NPT F - INLET FROM BOOSTER HEATER 3/4?[...]

  • Page 10

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 1: SPECIFICATION INFORMATION DIMENSIONS FOR TEMPSTAR HH GPX 5 LEGEND: A - DRAIN 1 1/2” NPT B - WATER INLET 1/2” NPT C - ELECTRICAL CONNECTION D - STANDARD WALL CLEARANCE WITH DISHTABLE 4” E - OUTLET TO BOOSTER HEATER 3/4” N.P.T. F - INLET FROM BOO[...]

  • Page 11

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 1: SPECIFICATION INFORMATION TABLE DIMENSIONS 6 TABLE DIMENSIONS CORNER INSTALLATION TABLE DIMENSIONS CONNECTION TO DISHMACHINE TABLE DIMENSIONS STRAIGHT THROUGH INSTALLATION 20 1/2” OPENING 2 1/2” 4” MINIMUM 2 1/2” 4” MINIMUM 20 1/2” OPENING [...]

  • Page 12

    7 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS[...]

  • Page 13

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 8 VISUAL INSPECTION: Before installing the unit, check the container and machine for damage. A damaged container is an indi - cator that there may be some damage to the machine. If there is [...]

  • Page 14

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 9 GAS BOOSTER HEATER ELECTRICAL INSTALLATION: The gas booster heater must have a separate electric hookup than that supplied to the dishmachine. Please refer to the manual supplied with your[...]

  • Page 15

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS GAS BOOSTER HEATER CONNECTIONS 10 Due to the fact that each customer may have different requirements for the orientation of the gas booster heater relative to the main dishmachine, the hose lengths that connect the t[...]

  • Page 16

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS GAS BOOSTER HEATER CONNECTIONS (CONTINUED) 11 THERMAL EXPANSION TANK RINSE SOLENOID VALVE RECIRC PUMP GAS BOOSTER HEATER PHOSPHATE WATER TREATMENT CARTRIDGE Y-STRAINER TEMPERATURE/PRESSURE GAGE HEATING COIL VACUUM BR[...]

  • Page 17

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS 12 PREPARATION: Before proceeding with the start-up of the unit, verify the following: 1. The pan strainer and pump suction strainer are in place and are clean. 2. The overflow tube and o-ring [...]

  • Page 18

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS (CONTINUED) 13 OPERATIONAL INSPECTION: Based upon usage, the pan strainer may become clogged with soil and debris as the workday progresses. Operators should regularly inspect the pan strainer [...]

  • Page 19

    14 SECTION 3: PREVENTATIVE MAINTENANCE[...]

  • Page 20

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 3: PREVENTATIVE MAINTENANCE PREVENTATIVE MAINTENANCE 15 The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator. However, this does not mean that some items will not wear out in time. Jackson highly [...]

  • Page 21

    16 SECTION 4: TROUBLESHOOTING[...]

  • Page 22

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 4: TROUBLESHOOTING COMMON PROBLEMS 17 WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service per - sonnel. Certain procedures in this section require electrical tests or measurements while power is ap[...]

  • Page 23

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 4: TROUBLESHOOTING COMMON PROBLEMS (CONTINUED) 18 Problem: Rinse water not reaching required temperature. 1. Faulty rinse heater. Check element for continuity; if open, replace heater. 2. Misadjusted/faulty thermostat(s). Verify operation and setting of t[...]

  • Page 24

    19 SECTION 5: SERVICE PROCEDURES[...]

  • Page 25

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 5: SERVICE PROCEDURES 20 These dishmachines are equipped with electrical solenoid valves to allow for automatic fill and rinse. These valves are designed to specific tolerances and design aspects that must be met in order to function properly. Ecolab offe[...]

  • Page 26

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 5: SERVICE PROCEDURES 21 4. When replacing the coil, ensure that when removing the coil wire cover that care is taken not to damage the wires inside. Using the medium flathead screwdriver, gently use it to open the cover enough to where it could be pulled[...]

  • Page 27

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 5: SERVICE PROCEDURES 22 13. Slowly remove the valve bonnet. Note: The spring for the plunger is located directly under the bonnet and may come free if you are not careful. Remove the plunger, spring and valve bonnet and place to the side. 14. Remove the [...]

  • Page 28

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 5: SERVICE PROCEDURES 23 19. Using the small flathead screwdriver, lift out the screen retainer. Verify that the holes in it are free of clogs and debris. 20. Again using the small flathead screwdriver, carefully remove the mesh screen from inside the val[...]

  • Page 29

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 5: SERVICE PROCEDURES 24 These dishmachines are equipped with vacuum breakers to serve as back-flow prevention devices. ASSE requirements specify what type of back-flow prevention is nec - essary on dishmachines. Vacuum breakers, unlike air gaps, have cer[...]

  • Page 30

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 5: SERVICE PROCEDURES 25 6. Your repair kit comes with a new plunger. Examine the old one and ensure that the mating surface is not damaged or cut. Also inspect the rubber seal on the top of the plunger to ensure it is in good condition and not torn. 7. I[...]

  • Page 31

    26 SECTION 6: PARTS SECTION[...]

  • Page 32

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TEMPSTAR GPX CONTROL BOX ASSEMBLY 27 20, 17 6, 4, 3 7 5 8, 9 10, 4 11, 4 13, 12 1 16 22 19, 4 23, 24 25, 4 14 18 2, 4 11, 4 21 15[...]

  • Page 33

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TEMPSTAR GPX CONTROL BOX ASSEMBLY (CONTINUED) 28 ITEM QTY DESCRIPTION Mfg. No. 1 1 Control Box Weldment 05700-002-57-08 2 1 Terminal Board, Dispenser 05940-001-97-91 3 1 Decal, Ground 09905-011-86-86 4 6 Locknut, 10-24 S/S Hex with Nylon [...]

  • Page 34

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TEMPSTAR HH GPX CONTROL BOX ASSEMBLY 4 7, 8 9 11 28 29 30 26*, 27* 24, 25 12, 13 14, 15 16 5, 6 10 1, 2, 3 5, 6 23, 13 21, 22, 20 17, 18 19, 20 29[...]

  • Page 35

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TEMPSTAR HH GPX CONTROL BOX ASSEMBLY (CONTINUED) 30 ITEM QTY DESCRIPTION Mfg. No. 11 Bracket, Electrical Box Mounting 05700-002-18-48 2 9 Locknut, 1/4"-20 S/S Hex with Nylon Insert 05310-374-01-00 39 Washer, 1/4"-20 I.D. S/S 053[...]

  • Page 36

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TEMPSTAR GPX HOOD ASSEMBLY 31 ITEM QTY DESCRIPTION Mfg. No. 11 Hood, Single Piece Weldment 05700-002-57-02 22 Bracket, Cantilever Support 05700-031-88-00 36 Wear Button .50 Dia. 05700-011-88-01 4* 1 Conduit Bracket (not shown) 05700-021-7[...]

  • Page 37

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TEMPSTAR HH GPX HOOD ASSEMBLY 32 ITEM QTY DESCRIPTION Mfg. No. 11 Hood Weldment 05700-002-01-23 26 Bolt, 1/4"-20 X 5/8" Long Hex 05305-274-24-00 3 26 Washer, 1/4" ID S/S 05311-174-01-00 4 26 Locknut, 1/4"-20 S/S Hex wi[...]

  • Page 38

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION FRAME ASSEMBLIES Front Panel Tempstar GPX 05700-002-36-65 Bolt, 1/4”-20 x 1/2” 05305-274-02-00 Locknut, 1/4”-20 S/S ] Hex with Nylon Insert 05310-374-02-00 Bullet Foot 05340-108-01-03 Frame Weldment Tempstar GPX 05700-031-48-01 Fram[...]

  • Page 39

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TUB ASSEMBLY 34 11 9, 10 2 3 6 7 12 13, 10 14 4 8 3 15 5 SEE PAGE ENTITLED “WASH MOTORS” 28, 29 21, 22 20 23 24 25, 26 31 30 1 27 16 15 17 18, 10 19 Nut, 1/4”-20 Serrated Nut 05310-011-66-49 Bracket, Motor Support Weldment Tempstar [...]

  • Page 40

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION TUB ASSEMBLY (CONTINUED) 35 ITEM QTY DESCRIPTION Mfg. No. 11 Tub Weldment, Tempstar GPX 05700-002-57-03 11 Tub Weldment, Tempstar HH GPX 05700-002-63-13 21 Rack Assembly 05700-002-01-00 32 Bulk Head Plug 04730-609-05-00 41 Gasket 05700-11[...]

  • Page 41

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION CANTILEVER ARM/DOOR ASSEMBLIES TEMPSTAR GPX 3 5 2 1 6 9 15, 16 17, 18 19, 11, 12 20 21, 25 22 23, 18 7 8 4 24, 18 14 13 10, 11, 12 Washer, Nylon 05311-369-03-00 Yoke 05700-000-75-78 Nut, 3/8"-16 S/S Hex Locking 05310-256-04-00 Clevis[...]

  • Page 42

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION CANTILEVER ARM/DOOR ASSEMBLIES TEMPSTAR GPX (CONTINUED) 37 ITEM QTY DESCRIPTION Mfg. No. 11 Cantilever Arm 05700-031-50-67 22 Spring Pin, 1/4" x 1 1/8" 05315-407-06-00 32 Yoke Assembly 05700-000-75-77 42 Rod, Spring 05700-002-29[...]

  • Page 43

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION CANTILEVER ARM/DOOR ASSEMBLIES TEMPSTAR HH GPX 38 17, 18 35, 24 33, 34 6 3, 4, 5 2 1 7 28 27, 22 29, 30 31, 32 26 25, 4, 5 23, 4, 24 10 9 19, 20 17, 18 36, 22 21, 22 8 11 13 12 14 15 16 12[...]

  • Page 44

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION CANTILEVER ARM/DOOR ASSEMBLIES TEMPSTAR HH GPX (CONTINUED) 39 ITEM QTY DESCRIPTION Mfg. No. 11 Cantilever Arm 05700-031-92-44 22 Sleeve, Cantilever Arm 05700-000-85-69 32 Screw, 1/4"-20 x 1 1/2" Long Hex Head 05305-274-23-00 44 [...]

  • Page 45

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION INLET PLUMBING ASSEMBLIES NOTE: ENSURE DIRECTION OF FLOW THROUGH THE PRESSURE REGULATING VALVE IS IN THE CURRECT DIRECTION. CONNECTS TO THE WASH TANK HEATING COIL OUTLET ITEM QTY DESCRIPTION Mfg. No. * 1 Plumbing, Inlet, Tempstar HH GPX 0[...]

  • Page 46

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION RINSE HEADER PLUMBING ASSEMBLY 41 Rinse Header Plumbing Assembly, Tempstar GPX 05700-002-56-67 Rinse Header Plumbing Assembly, Tempstar HH GPX 05700-002-58-02 ITEM QTY DESCRIPTION Mfg. No. * 1 Rinse Hose Assembly 05700-002-57-05 1 Hose, 1[...]

  • Page 47

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION RECIRCULATING PLUMBING ASSEMBLY 42 ITEM QTY DESCRIPTION Mfg. No. * 1 Plumbing, 110V Recirculating System Assembly 05700-002-56-64 * 1 Plumbing, 208-230V Recirculating System Assembly 05700-002-56-65 1 1 Tubing Assembly 05700-002-56-66 2 1[...]

  • Page 48

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION RINSE SOLENOID VALVE & VACUUM BREAKER REPAIR PARTS KITS 43 Complete 110 Volt Solenoid Valve Assembly 04810-100-12-18 Coil & Housing only 06401-003-07-43 Complete 220 Volt Solenoid Valve Assembly 04810-100-09-18 Coil & Housing [...]

  • Page 49

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION WASH & RINSE ARM/MANIFOLD ASSEMBLIES (TEMPSTAR GPX) 13 19 16 11 12 15 14 2, 3, 4 5 7 16, 8 6, 18 5 9 7 1 DETAIL “B” WASH ARMS & MANIFOLD DETAIL “A” FINAL RINSE ARMS & MANIFOLD 18 18 18 18 5 10 9 17 16 2, 3, 20 5 9, 10 [...]

  • Page 50

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION WASH & RINSE ARM/MANIFOLD ASSEMBLIES (TEMPSTAR GPX) (CONTINUED) 45 ITEM QTY DESCRIPTION Mfg. No. 11 Upper Manifold 05700-031-34-82 24 Nut, 3/8"-16 S/S Hex 05310-276-01-00 34 Lockwasher, 3/8 05311-276-01-00 42 Bolt, Hex 3/8”-16 [...]

  • Page 51

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION WASH & RINSE ARM/MANIFOLD ASSEMBLIES (TEMPSTAR HH GPX) 46 13 16 19 14 11 12 15 15 2, 3, 4 5 7 17, 8 6, 18 5 9 7 1 DETAIL “B” WASH ARMS & MANIFOLD DETAIL “A” FINAL RINSE ARMS & MANIFOLD 18 18 18 18 5 10 21 17 2, 3, 20 5[...]

  • Page 52

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION WASH & RINSE ARM/MANIFOLD ASSEMBLIES (TEMPSTAR HH GPX) (CONTINUED) 47 ITEM QTY DESCRIPTION Mfg. No. 11 Upper Manifold 05700-031-34-82 24 Nut, 3/8"-16 S/S Hex 05310-276-01-00 34 Lockwasher, 3/8 05311-276-01-00 42 Bolt, Hex 3/8”-[...]

  • Page 53

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION COIL ASSEMBLY 48 Stand C, Coil Support 05700-002-08-52 Coil Weldment 05700-021-41-38 Stand D, Coil Support 05700-002-08-53 Stand B, Coil Support 05700-002-08-51 Adapter, Coil Nut 2 per assembly 05700-011-17-85 Washer, Coil 2 per assembly [...]

  • Page 54

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION EXHAUST FAN CONTROL OPTION/SAFETY DOOR INTERLOCK (SDI) OPTION 49 Exhaust Fan Control Delay Timer 05945-011-65-44 Exhaust Fan Control 2” Din Rail 05700-002-36-09 Exhaust Fan Control Terminal Board 05940-011-84-41 Safety Door Interlock Bo[...]

  • Page 55

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION 50 TEMPSTAR GPX FALSE PANEL INSTALLATION 1. Loosen the rack assembly from the unit. 2. False panel will mount to the rack; inside the dishmachine. 3. Position panel in unit on side to be closed. 4. Hold panel against side of dishmachine a[...]

  • Page 56

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION 51 TEMPSTAR HH GPX FALSE PANEL INSTALLATION 1. Remove the rack assembly from the dishmachine. 2. The false panel will mount inside of the dishmachine. 3. Position the panel in the dishmachine on the side to be closed. 4. Hold the panel ag[...]

  • Page 57

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 6: PARTS SECTION 52 DRAIN QUENCH ASSEMBLY From the existing drain, attach the two additional Tees using the 1-1/2” NPT Close Nipples. Tighten the Reducers into the Tees as shown above. Attach the Modified Compression Fitting into the 1-1/2” to 1/4” [...]

  • Page 58

    53 SECTION 7: ELECTRICAL SCHEMATICS[...]

  • Page 59

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 7: ELECTRICAL SCHEMATICS TEMPSTAR GPX 115 VOLT - 50/60 HERTZ - SINGLE PHASE 54[...]

  • Page 60

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 7: ELECTRICAL SCHEMATICS TEMPSTAR GPX 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE 55[...]

  • Page 61

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 7: ELECTRICAL SCHEMATICS TEMPSTAR HH GPX 115 VOLT - 50/60 HERTZ - SINGLE PHASE 56[...]

  • Page 62

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 7: ELECTRICAL SCHEMATICS TEMPSTAR HH GPX 208-230 VOLT - 50/60 HERTZ - SINGLE PHASE 57[...]

  • Page 63

    Tempstar/HH GPX Series Technical Manual 7610-002-57-32 Issued: 07-24-2006 Revised: N/A SECTION 7: ELECTRICAL SCHEMATICS EXHAUST FAN CONTROL OPTION/SAFETY DOOR INTERLOCK (SDI) OPTION 58[...]