A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Jenn-Air JXT8136ADS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Jenn-Air JXT8136ADS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Jenn-Air JXT8136ADS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Jenn-Air JXT8136ADS should contain:
- informations concerning technical data of Jenn-Air JXT8136ADS
- name of the manufacturer and a year of construction of the Jenn-Air JXT8136ADS item
- rules of operation, control and maintenance of the Jenn-Air JXT8136ADS item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Jenn-Air JXT8136ADS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Jenn-Air JXT8136ADS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Jenn-Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Jenn-Air JXT8136ADS.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Jenn-Air JXT8136ADS item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
RANGE HOOD INST ALLA TION GUIDE T ABLE OF C ONTENTS Safety Instructions.................................................... 1 List of Materials....................................................... 2 Mounting Heights.................................................... 3 Ducting.................................................................... 4 [...]
-
Page 2
INST ALLA TION GUIDE Read all Instructions before Installing and operating this appliance MODEL: JXT8136ADS JXT8142ADS Installation The installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. DO NOT attempt to install this a ppliance yourself. Injur y could result from inst[...]
-
Page 3
LIST OF MA TERIALS 2 1 - Hood Body 1 - Duct Cover Assembly (2 pieces) 1 - Parts Bag: 1 - Duct Cover Mounting Bracket 2 - Mounting Brackets Packet of Mounting Screws 2 - Metallic Filters 1 - Metallic Bitterfly Damper NO DUCTING IS INCLUDED[...]
-
Page 4
INST ALLA TION 3 MOUNTING HEIGHTS & CLEARANCE DUCTING 29"-46.65" 5.31" 36" Min 24"-Max 32" *Min 89.94" *Max 113.71" A minimum of 6" round or 3-1/4” x 10"rectangular duct must be used to maintain maximum air flow efficiency . Always use rigid-type metal ducts only . Flexible ducts could restric[...]
-
Page 5
INST ALLA TION 4 DUCTING NEVER exhaust air or terminate duct work into spaces between walls, cra wl spaces, ceiling,a ttics or garages. All exhaust must be ducted to the outside. Use Metal ductwork only . Fasten all connections with sheet metal screws and tape all joints w/ certified Silver T a pe or DuctT a pe. Some Ducting Options: WARNING FIRE H[...]
-
Page 6
INST ALLA TION 5 SPECIFICA TIONS ELECTRICAL All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow National electrical [...]
-
Page 7
INST ALLA TION 6 INST ALLA TION Mounting the Range Hood 1. Add and secure blockings (minimum 2x4 studs) onto ceiling joist. 2. Center , mark and fasten Ceiling Plate onto ceiling where hood is to be hung. Make sure front of bracket is facing as shown on diagram. 3. Determine height of hood, measure and attach four support arms onto blower unit with[...]
-
Page 8
INST ALLA TION 7 INST ALLA TION Mounting the Range Hood 8. Lift canopy and snap locking tabs into blower unit. 9. Fasten canopy to blower with screw pro vided from inside of canopy . 10. Push telescopic duct section up in place and fasten. Note: Butterfly damper may be installed by placing it ontop of the motor housing. locking tabs[...]
-
Page 9
6" straight pipe wall pipe strap 6" T connector or 90 elbow INST ALLA TION 8 DUCTLESS CONVERSION Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and exhaust from cooking is draw[...]
-
Page 10
T ABLE DES MA TIÈRES Consignes de sécurité...............................................1 Liste des matériaux...................................................2 Hauteurs de montage............................................... 3 Canalisation............................................................. 4 Caractéristiques tec hniques.........[...]
-
Page 11
MODELE: JXT8136ADS JXT8142ADS Installation Les procédures d’installation décrites dans ce guide s’adressent à des installateurs qualifiés, à des techniciens de service ou à des personnes possédant des compétences similaires. NE ten- tez P AS d’installer cet appareil vous-même. L ’installation de l’unité peut causer des blessures[...]
-
Page 12
LISTE DES MA TÉRIAUX 2 1 - Hotte 1 - Caches de conduits (2) 1 - Sachet de pièces: 1 - Languettes de montages des caches de conduits 2 - Languettes de montages Paquet de vis de montage 2 - Filtres Métaliques 1 - Filtre P apillon à registre AUCUNE CANALISA TION N’EST INCLUSE[...]
-
Page 13
29"-46.65" 5.31" 36" Min 24"-Max 32" *Min 89.94" *Max 113.71" INST ALLA TION 3 HAUTEURS DE MONT AGE ET DÉGAGEMENT CANALISA TION La hauteur de montage minimale entre le dessus de la cuisinière et le dessous de hotte doit être d’au moins 61 cm (24 po). La hauteur de montage maximale ne doit pas excéder 81[...]
-
Page 14
capuchon mural latéral avec registre anti-refoulement Soffite ou vide sanitaire capuchon mural latéral avec registre anti-refoulement Pente de toit avec solin et capuchon capuchon mural latéral avec registre anti-refoulement Soffite ou vide sanitaire capuchon mural latéral avec registre anti-refo[...]
-
Page 15
Câble de verrouillage INST ALLA TION 5 CARACTÉRISTIQUES TECHNIQUES ÉLECTRICITÉ A VERTISSEMENT T ous les travaux électriques doivent être effectués par un électricien qualifié ou une personne pos- sédant des connaissances techniques et de l’expérience similaires. Pour votre sécurité personnelle, retirez le fusible ou coupez le dis[...]
-
Page 16
INST ALLA TION 6 INST ALLA TION Montage de la hotte de cuisinière 1. Placez les matériaux d’assujettissement (minimum 2 morceaux de 2 x4 ). 2. Centrez la plaque d’assujettissement sur le plafond, tracez un point de repère puis fixez-la à l’emplacement de pose de la hotte. Assurez- vous que l’avant du support pointe du côté indiqué da[...]
-
Page 17
INST ALLA TION 7 INST ALLA TION Montage de la Hotte de Cuisinière 8. Soulevez le déflecteur et enclenchez les languettes de verrouillage dans la soufflante. 9. Fixez le déflecteur à la soufflante à l’aide des vis fournies, en vissant depuis l’intérieur du déflecteur . 10. Poussez la section du conduit télescopique vers le haut pour qu?[...]
-
Page 18
6" straight pipe wall pipe strap 6" T connector or 90 elbow INST ALLA TION TRANSFORMA TION EN SYSTÈME DE RECYCLAGE La transformation de cette unité en système de recyc lage est recommandée pour des a pplications où il est impossible d’installer un système de conduits d’évacuation. Lors de la conversion, la hotte fonc- tionne en[...]
-
Page 19
C ONTENIDOS Instrucciones de Seguridad.......................................1 Lista de Materiales................................................... 2 Altura de Montado................................................... 3 T ubería de Extracción...............................................4 Especificaciones......................................[...]
-
Page 20
GUIA DE INST ALACION Lea todas las instrucciones antes de instalar y usar este electrodoméstico MODELO: JXT8136ADS JXT8142ADS Instalación La instalación descrita en este manual ha sido preparada para instaladores calificados, técnicos de servicio o personas con un entrenamiento similar y calificado. NO intente instalar este elec- trodoméstico [...]
-
Page 21
LIST A DE MA TERIALES 2 1 - Cuerpo de la campana 1 - Ensamblado de la cubierta del conducto (2 partes) 1 - Bolsa de partes: 1 - Sujetador de montaje para la cubierta del conducto 2 - Sujetadores de montaje Paquete de tornillos de montaje 2 - Filtros metálicos 1 - Regulador de tiro de chimenea metálico tipo mariposa NO SE INCLUYE LA TUBERIA DE EXT[...]
-
Page 22
INST ALACION 3 AL TURA DE MONT ADO Y ESP ACIO LIBRE TUBERIA DE EXTRACCION 29"-46.65" 5.31" 36" Min 24"-Max 32" *Min 89.94" *Max 113.71" La altura mínima de montado entre la parte inferi- or de la campana y la parte superior de la cocina no debe ser inferior a 24”. La altura de montado máxima no debe ser s[...]
-
Page 23
INST ALACION 4 TUBERIA DE EXTRACCION NUNCA haga escapar el aire o termine las tuberías entre espacios de la pared, sofitos, techos, áticos o garajes. T odos los escapes de aire deben ser dirigidos hacia el exterior . Use tuberías metálicas solamente. Asegure todas las conexiones con tornillos para metal laminado y selle todas las junturas con c[...]
-
Page 24
INST ALACION 5 ESPECIFICACIONES INST ALACION ELECTRICA T oda instalación eléctrica debe ser realizada por un electricista calificado o por una persona con conocimientos técnicos similares y con experiencia equivalentes. Para su seguridad personal, retire los fusibles del hogar o el interruptor abierto antes de comenzar la instalación. No utilic[...]
-
Page 25
INST ALACION 6 Montando la Campana de Cocina 1. Agregue y afirme los bloqueadores al techo (mínimo postes de 2x4). 2. Centre, marque y asegure la Placa para el T echo en el lugar donde se colgará la campana. Asegúrese de que la parte frontal del sujetador de pared esté en la dirección indicada en el diagrama. 3. Determine la altura de la campa[...]
-
Page 26
INST ALACION 7 INST ALACION Montando la Campana de Cocina 8. Levante la campana y enganche las proyecciones de cierre en la unidad de extracción. 9. Fije la campana al extractor con el tornillo que se propor ciona desde el interior de la campana. 10. Empuje la sección de la tubería telescópica hacia arriba hasta que quede en el lugar apropiado [...]
-
Page 27
INST ALACION 8 CONVERSION SIN TUBERIA DE EXTRACCION La conversión sin tubería de extracción está hecha para situaciones en las cuales no es posible instalar una tubería de extracción de aire. Al ser convertida, la campana funciona como una campana de “purificación” en vez de una campana de extracción. Los humos y va pores producidos al [...]