Go to page of
Similar user manuals
-
Cooktop
Jenn-Air DOWNDRAFT RADIANT COOKTOP
32 pages 0.83 mb -
Cooktop
Jenn-Air PRO-STYLE CVG4380P
23 pages 1.2 mb -
Cooktop
Jenn-Air CCGP2420P
12 pages 1.21 mb -
Cooktop
Jenn-Air JIC4536X
4 pages 0.51 mb -
Cooktop
Jenn-Air CVE407
10 pages 0.41 mb -
Cooktop
Jenn-Air JGCP648ADP
1 pages 0.06 mb -
Cooktop
Jenn-Air W10197057B
32 pages 0.89 mb -
Cooktop
Jenn-Air W10526080A
24 pages 2.54 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Jenn-Air W10253462A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Jenn-Air W10253462A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Jenn-Air W10253462A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Jenn-Air W10253462A should contain:
- informations concerning technical data of Jenn-Air W10253462A
- name of the manufacturer and a year of construction of the Jenn-Air W10253462A item
- rules of operation, control and maintenance of the Jenn-Air W10253462A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Jenn-Air W10253462A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Jenn-Air W10253462A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Jenn-Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Jenn-Air W10253462A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Jenn-Air W10253462A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTALLATION INS TR UCTIONS ELECTR IC DO WNDRAFT SLIDE-I N RANGES INSTR UCTIONS D’INSTALLATION DES CUISINIÈRES ÉLECTRIQUE À ÉV ACUATION DESCENDANTE E NCASTRABLE T able of Contents/T able des matières RANGE SAFETY .................................... ......................................... 2 INSTALLATION REQUIREMENTS .......................[...]
-
Page 2
2 RANGE SAFETY You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. Your safety and the safety[...]
-
Page 3
3 INST ALLA TIO N REQUIREMENTS T ools and Parts Gat her the r equ ired tools an d parts befor e star ting instal lation . Read and fol low the instruction s pr ovid ed with any tools listed here. To o l s n e e d e d Parts supplied Check that all part s are included. ■ 3 - #1 0-32 hex n uts (attac hed to term inal block ) ■ 3 - T ermi nal lug s[...]
-
Page 4
4 Produc t Dimensions * Range can be raised ap proximately 1" (2.5 cm) by adjusting the le veling legs. ** When installed i n a 24" (61 cm) bas e cabinet wit h 25" (63.5 cm) countertop; fr ont of oven door pr otrudes 2 ¹⁄₂ " (6.4 cm) beyond 24" (6 1.0 cm) ba se cabine t. Cabinet Dimensions Cabine t opening d imensions [...]
-
Page 5
5 V enting Requirements IMPORT ANT : This range must be exhausted outdoors. See “V enting Metho ds” sec tion. ■ Do not terminat e the vent system in an at tic or other enclosed area. ■ Us e a Jenn- Air wall cap. ■ V e n t system m ust termi nate t o the o utside. ■ Use only a 6" (1 5.2 cm) r oun d metal ve nt or a 3¼ x 10" (8[...]
-
Page 6
6 Left or Righ t Side V e nting V ent ing Behind Cab inet Kickplate Concre te Slab Installations - Exha ust Through W all Concrete Slab Installations - Exhaust Through Window W ell IMPORT ANT : Window well installati on for ele ctric mode ls only . Calculating V ent System Length IMPORT ANT : This range is rated at 60 ft (18.3 m) of straight duct. [...]
-
Page 7
7 Example vent system NOTE : For external venting, flexi ble vent is not r ec ommended. Flexible v ent creates back pressure and air turbu lence that greatly r educe performance. Electrical Requirements - U .S.A. Only If code s permit a nd a sepa rate grou nd wire is used, it is recommended that a qual ified electric al installer d etermine that th[...]
-
Page 8
8 If conne cting to a 3-wire system: Local codes may permit the use of a UL li sted, 3-wire, 250-vol t, 40- or 50-amp range power su pply co r d (p igtail ). This cord contains 3 copper conductors wit h ring termina ls or open-end spade termi nals with upturned ends, termina ting in a NEMA T ype 10-50P plug on the supply end . Connectors on the app[...]
-
Page 9
9 INSTALLATION I NSTR UCTIONS Unpack R ange 1. Remove shipping materials , tape and film fr om the range. Keep cardboard bottom unde r range. 2. Remove oven racks a nd parts package from inside oven. 3. T o remove cardboard bottom, place ran ge on its back, take 4 cardboard corners from the carton. Stack on e cardboar d corner on top of another . R[...]
-
Page 10
10 W all Mountin g 5. Using the Ph illips screwdriv er , mount anti-ti p bracket to the wall or floor wit h the two #12 x 1 ⁵⁄₈ " screws pr ovided. Install Downdraft System Determine Equivalent Le ngth of V ent System This range is eq uipped with a du al range blower . It is shipped from the factory for Low Range in stallations. If ven t[...]
-
Page 11
11 5. Mount b lower mo tor to the f lo or with 4 - #8 x ¾" h ex head scr ews pr ovided. 6. Go to the “Electri cal Connection ” section. Floor V enting 1. Mark the floor at th e center of the cabinet op ening. 2. Posi tion temp late on f loor by ma tching th e cente rline of th e template to the centerl ine drawn on the floor and pl ace te[...]
-
Page 12
12 6. Connect vent system to blower motor outlet (op tion 1 shown) with 4 - # 8 x ¾" he x head scr ews pr ovided. 7. Go to the “Electri cal Connection ” section. Left or Righ t Side V e nting 1. Mark cabinet si de for either a left or right si de vent hole loca tion. 2. Mark and cut a 5½" ( 13.9 cm) diamete r hole in the de sired ca[...]
-
Page 13
13 7. Remove th e bracket f rom the other s ide of the bl ower motor , r otate 1 80° and se cure with 4 l ocknuts. 8. Position 2 wood spa cers and mount them to the floor . 9. Mount b lower motor t o wood spacers using 4 - # 8 x ¾" he x head screws provided . NOTE : V ent syste m will be conn ected after range has b een moved int o it’ s f[...]
-
Page 14
14 Electrical Connection - U .S.A. Only Power Supp ly Cord Di re ct Wi re 1. Discon nect power . 2. Use Phill ips screwd river to r emove the termina l block cover screw located on the back of the range. Pull co ver down and towa rd you t o remov e cove r . 3. Remove plasti c tag holding three 10-32 hex nut s fr om the middle post of th e terminal [...]
-
Page 15
15 Style 2: Direct wire strain r elief ■ Use Phill ips scre wdriver to r emove scre ws from p anel on back of range. ■ Lift range ba ck pane l up and off. ■ Use Phill i ps s crewd river to r e m ove scr ews and slide cord/conduit plat e down and out. ■ Position cord/conduit plat e as shown in the followin g illu stration . ■ Replace cord/[...]
-
Page 16
16 Electrical Connection Options 4-wire c onnection: Power Supply Cor d Use this method for: ■ New br anch-c ircu it installa tions (1996 N EC) ■ Mobile homes ■ Recreational v ehicles ■ In an area where local codes p r oh ibit grounding through the neut ral 1. Part of metal grou nd strap must be cut out and removed. 2. Use Phill ips scr ewd[...]
-
Page 17
17 3-wire c onnection: Power Supply Cor d Use this meth od only if local code s permit connect ing chassis gr ound conductor to neutral wir e of power supply cor d . 1. Feed the power su pply cord through the openi ng in the cord/ conduit plate on bott om of range. Allow enough slack to easily at tach the wiring to th e terminal block. 2. Use ³⁄[...]
-
Page 18
18 3. Pull the cond uit through the strain relief on cord/conduit pla te on bottom of range . Allow enough slack to easi ly attach wiring to t he terminal block. 4. Attach terminal l ugs to line 1 (black) , neutral (white ), and li ne 2 (red) wire s. Loosen (do not remove) the set screw on the fron t of the termin al lug and ins ert exposed wire en[...]
-
Page 19
19 2. Attach t e rmina l lugs to line 1 (black) , bare (gr een) gr ound, and line 2 (red) wires. L oosen (do not remove ) the se t screw on t he front of the terminal lug and insert expos ed wire end through botto m of termi nal lugs . Secur ely tigh ten se t scre w to tor que as shown in the following Bar e Wire T orque Specifications chart. Bare [...]
-
Page 20
20 8. Check that the an ti-tip bracket is instal led and that el ectrical cords are not kinked. Use a flas hlight to look und erneath the bottom of the range. ■ Look for the anti-tip bra cket securely attached to fl oor or wall. ■ Slide range bac k so re ar range foot is under anti-ti p bracke t. 9. Level the ran ge. a.) Place ra ck in oven. b.[...]
-
Page 21
21 12. Insert downdraft vent fil ter and place vent cover over opening. 13. Reco nnect power . Complete Installation 1. Check that all parts are now installed . If there is an extra part, go back t hrough the ste ps to see wh ich step wa s skippe d. 2. Check t hat you ha ve all of y our tools. 3. Dispose of/recycle all p ackaging materials. 4. Chec[...]
-
Page 22
22 For direct-wired ranges: 1. Discon nect power . 2. Discon nect range fr om downdraft ve nt system. 3. Slide range forw ard. 4. Complete clean ing or maintenance . 5. T o check that anti-ti p bracket is install ed, remove access panel an d use a fla shlight and look under neath the bottom o f the range: ■ Look for the anti-ti p bracket securely[...]
-
Page 23
23 SÉCUR ITÉ DE LA CUISINIÈRE Risque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions. Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions. Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure[...]
-
Page 24
24 EXIGENCES D’INSTALL ATION Outils et pièces Rassembler les outils et composants nécessaires avant d’entreprendre l’inst allation . Lire et observer les in structions four nies avec chacun des outils de la liste ci-de ssous. Outils nécessaires Pièces four nies Vérifier que t outes les pièces sont présentes. ■ 3 écr ous hexagonaux d[...]
-
Page 25
25 Autres critères à r especter pour une installat ion en résidence mobile : ■ Dans l e cas de l’inst allation de cette cui sinière dans un e résidenc e mobile, la cuis inière doit êt r e fi xée au planch er durant tout dép lacement du véhi cule. T o ute méthode de fixat ion de l a cu isinière est a déquate d a ns la mesure où el [...]
-
Page 26
26 Exigences co ncer nant l ’év acua tion IMPORT ANT : Cette cuisinière doit être ventilée vers l’ex térieur . V oir la section “Méth odes d’évacu ation”. ■ Ne pas te rminer le circuit d’évacu ation dans un grenie r ou dans un autre espace fermé . ■ Utiliser une bou che de décharge murale Jenn-Air . ■ Le circuit doit év[...]
-
Page 27
27 Méthodes d’év acuation Les méthodes commu nes d’évacuation sont illustrées pou r une cuisi nièr e à aspi ration p ar le bas . L ’évacua tion de la cu isinièr e à aspi ration par le bas peut se fa ire par l e mur ou le pla ncher . Évacuation par le mur Évacuat ion par le plancher Évacuation entre solives de plancher Évacuat io[...]
-
Page 28
28 Calcul de la longueur effecti ve du cir cuit d’év acua tion IMPORT ANT : Cette cuisinière accep te jusqu’à 60 pi (1 8,3 m) de conduit d r oit. Le mode à fai ble aspiration admet jusqu’à 30 pi (9,1 m); le mode à forte aspi ration admet de 31 pi (9,4 m) à 60 pi (1 8,3 m). Si la longueur équ ivalente de cond uit dépa sse 30 pi (18,3 [...]
-
Page 29
29 Spécif ications électriques Si l’ on utilis e un con ducteur disti nct de liai son à la t e rr e lorsque les codes l e permettent, il est r ecommandé qu ’un électric ien qualifi é vérifie que la l iaison à la te rr e est ad équate et la sect ion des fils conforme au x codes locaux. Vérifier que l e raccord ement à l a source d’?[...]
-
Page 30
30 INSTR UCTIONS D ’INSTALLATION Déballage de la cuisinière 1. Ôter les matériau x d’emballage, le ruban adhésif et la pelli cule pr otectrice de la cuisin ière . Gard er la bas e de carton sous l a cuisini èr e. 2. Retirer les grilles de fou r et le sachet de pi èces de l’intérieur du four . 3. Pour r etirer la base en carton, place[...]
-
Page 31
31 Installation de la brid e antibasculement 1. Ôter la bride antibasculement fixée p ar du ruban adhési f à la pochette contenant la docu mentation. 2. Déterminer l a méthode de montage à uti liser : au plancher ou au mur . Pour un plan cher en pierre ou en briquetage , on peut utilis er la méthode d e montage au mur . 3. Détermin er et m[...]
-
Page 32
32 Évacuation par le mur arrièr e 1. T racer sur le mur l’ax e central de l’ouverture entre les placards. 2. Vérifier l’ absence d’obstruct ion avant de trace r l’emplacemen t du trou d’évacuation. T racer une ligne horizontale à 8 ³⁄₁₆ " (20,8 c m) du sol. T racer un e ligne verticale à droite de l’ax e central entr[...]
-
Page 33
33 Évacuat ion par le plancher 1. T racer au sol l’ axe central de l ’ouverture entre les placa r d s. 2. Placer le gabarit sur le sol à 2¼ " (5,7 cm) du mur arrièr e en faisant correspondre son axe cent ral avec l’axe centra l tracé au sol . 3. Détermin er la position correcte du t r ou d’évacuation en fonc tion des obstru ctio[...]
-
Page 34
34 6. Raccorder le circuit d’ évacuation à la sortie du moteur du ventilat eur (option 1 il lustrée) avec les 4 vi s n° 8 x ¾" à tête hexagonale four nies. 7. V oir la section “Raccordement élec trique”. Évacuat ion par la gauche ou par la droite 1. Repérer sur le côté du pl acard l’emplacement du trou d’évacuat ion à d[...]
-
Page 35
35 7. Déviss er le support de l’ autre côté du ventilate ur , le faire pivoter de 18 0° et le fixer avec les 4 é cr ous de blocage. 8. Placer 2 cales en bois et les fixer au sol. 9. Fixer le ven tilateur aux cal es en bois ave c les 4 vis n° 8 x ¾" à tête hexagon ale fournies . REMARQUE : Le circuit d’évacuati on sera raccordé u[...]
-
Page 36
36 7. Retir er le car ton ou l e pann eau de f ibr e dur de so us la cuisini èr e. À deux personn es ou plus, déplacer douceme nt la cuisin ière à son e mplacement f inal. 8. Vérifier que l a bride antibasc ulement est instal lée et que les câbles él ectriques ne son t pas pincés. A u moyen d’une tor che éle ctriqu e, in specter le des[...]
-
Page 37
37 Évacuation laté rale (évacuation par la gauche illu strée) Raccorder le conduit d’évac uation flexible à la cu isinière et le circuit d’évacu ation à la sortie du ventilateur . 11. Repla cer le panneau d’a ccès. 12. Insérer le fi ltre d’évacuation p ar le bas et place r la plaque de décharge pa r -dessu s l’ouv erture. 13.[...]
-
Page 38
38 Déplace ment de la c uisinière Lorsqu’on d éplace la cuisi nière, la faire glisser sur une plan che de carton ou en matériau d ur pour éviter d’endommager le re vê te me nt d u s ol . Si le dépl acement de la cui sinière est néces saire pour le net toya ge ou l’ entr etien : Cuisinières alimentées par cordon d’alimentation : [...]
-
Page 39
39 Notes[...]
-
Page 40
W1025346 2A © 2009. All r ights reserv ed. Tous dr oits réservé s. ® Regist ered Trade mark/TM Trade mark of Jenn- Air, U.S.A. Used under l icense by Ma ytag Limited i n Canada. ®Mar que dé posée/TM Ma rque de com merce de Jenn -Air, U.S.A . Emploi sous l icen ce pa r Mayt ag Li mite d au Ca nada. 5/09 Printed in U.S.A. Impri mé aux É.-U.[...]