Kairak KRES manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Kairak KRES, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kairak KRES one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Kairak KRES. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Kairak KRES should contain:
- informations concerning technical data of Kairak KRES
- name of the manufacturer and a year of construction of the Kairak KRES item
- rules of operation, control and maintenance of the Kairak KRES item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kairak KRES alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kairak KRES, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kairak service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kairak KRES.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Kairak KRES item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Kairak IM - ES - REV 5 - 09 - 0 6 500 S . State College Blvd. Fullerton , CA 9 2831 PN 4406010 - 1 A Div of ITW FEG , LLC. INSTRUCTION MANUAL KRES Equipment Stands Self - Contained and Remote[...]

  • Page 2

    KAIRAK Page 2 - 2 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 GENERAL Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available as a refrigerated or freezer storage compartment. The condensing systems are designed to be installed with minimal clearance to walls or other [...]

  • Page 3

    KAIRAK Page 3 - 3 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 LOCATING THE EQUIPMENT All model lengths can be installed with minimal clearance at the back and sides of the units INSTALLING PARTS SHIPPED LOOSE COMPRESSOR FILTER Remove louvered panel by lifti ng up and pulling out entire panel. Slide the filter into the tracks located below the compr[...]

  • Page 4

    KAIRAK Page 4 - 4 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 ELECTRIC CONDENSATE EVAPORATOR Some units may come with the electric condensate evaporator shipped loose. To install, attach the two (2) m ounting rails to the bottom of the cabinet with 4 or 6 (depending on the model) #6 - 32 x 3/8 phillips head screws. Place the condensate evaporator i[...]

  • Page 5

    KAIRAK Page 5 - 5 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 REFRIGERATION LINES (Remote Units) WARNING: REFRIGERATION LINES ARE SHI PPED UNDER PRESSURE. USE CAUTION WHEN OPENING LINES. On remote units, refrigeration lines for suction and supply are located on the back of the unit near the bottom. The suction line is marked “Suction” and is 3/[...]

  • Page 6

    KAIRAK Page 6 - 6 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 PRESTART CHECKS DEFROST TIME CLOCK SETTINGS All models have a defrost time clock that is set to defrost 3 times a day for a 15 minute time period. The defrost settings are factory set at 12:00 a.m. to 1:00 a.m., 2:00 a.m. to 2:30 a.m. and 5:00 a.m. to 6:00 a.m. To chan ge this setting, s[...]

  • Page 7

    KAIRAK Page 7 - 7 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 TEMPERATURE CONTROL SETTINGS All temperature set tings are preset at the factory but local conditions may necessitate slight adjustments. On self - contained refrigerated models the temperature control (shown in Fig. 5) is located in the compressor compartment. KRES Self - contained Fig.[...]

  • Page 8

    KAIRAK Page 8 - 8 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 On remote models, the controls can either be inside the control cabinet similar to that shown in Fig. 5 or inside the refrigerated base as shown in Fig. 6. KRES Remote Fig. 6 On both self - contained and remote refrigerated units, the temperature control should be set at 37 ° F with a 3[...]

  • Page 9

    KAIRAK Page 9 - 9 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 OPERATION A thermometer is provided on all refrigerator and f reezer cabinets. Allow cabinet to reach normal operating temperature before loading (approximately 1 hour). The refrigerated storage cabinet is designed to maintain temperatures between 33 ° F and 40 ° F, or –2 ° F to 2 ?[...]

  • Page 10

    KAIRAK Page 10 - 10 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 Fig. 7 Fig. 8 Cross Rail Lock Cross Rail Lock (1 on each side of drawer) Drawer Module Liner Lock Black Clamping Knob Black Clamping Knob[...]

  • Page 11

    KAIRAK Page 11 - 11 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 CONDENSING UNIT WARNING: DISCONNECT ELECTRICAL POWER SUPP LY BEFORE CLEANING ANY PARTS ON THE UNIT. The condensing unit coil and filter must be cleaned regularly on self - contained models for optimal performance. The operating environment will affect the required frequency of cleaning[...]

  • Page 12

    KAIRAK Page 12 - 12 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE Compressor fails to operate. • Power failure. • Plug loose in receptacle or unplugged. • Blown fuse or tripped circuit breaker. • Main power switch is Off. • Temperature controls or time clock not set properly. Compress or operates for p[...]

  • Page 13

    KAIRAK Page 13 - 13 - IM - ES - REV 5 - 09 - 06.doc 5 - 09 - 06 A Div of ITW FEG , LLC. 1 - YEAR LABOR WARRANTY Kairak warrants that equipment manufactured by Kairak will be free from defects in material and workmanship for a period of 1 - year beginning 30 days after ship date. All work must be pre - approved by the factory to qualify for reimburs[...]