Go to page of
Similar user manuals
-
Satellite Receiver
Kathrein UFE 370-S
36 pages 1.97 mb -
Modem
Kathrein DCV 10
16 pages 1.28 mb -
Miscellaneous
Kathrein MFK 11 - CATV-Analyzer
40 pages 0.26 mb -
Satellite TV System
Kathrein AOS 65
6 pages 0.46 mb -
TV signal amplifier
Kathrein VOS 20/RA-1G
20 pages -
External Hard Drive
Kathrein UFZ 113
2 pages -
Stereo Amplifier
Kathrein VOS 11F
2 pages 0.1 mb -
Miscellaneous
Kathrein UFG 308
20 pages 0.58 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Kathrein MVG 10, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kathrein MVG 10 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Kathrein MVG 10. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Kathrein MVG 10 should contain:
- informations concerning technical data of Kathrein MVG 10
- name of the manufacturer and a year of construction of the Kathrein MVG 10 item
- rules of operation, control and maintenance of the Kathrein MVG 10 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kathrein MVG 10 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kathrein MVG 10, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kathrein service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kathrein MVG 10.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Kathrein MVG 10 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operator's manual Video Sweep Generator MVG 10 Order no.: 208 320[...]
-
Page 2
2[...]
-
Page 3
Preface 3 Preface Dear customer, This handbook aims to help you use the various functions of the MVG10 in the optimal manner. Please pay attention to all instructions. Kathrein-Werke KG has made every effort to ensure the information and descriptions are correct and complete. We reserve the right to make changes to this handbook without prior notic[...]
-
Page 4
4[...]
-
Page 5
Contents 5 Contents Preface ........................................................................................................................ .............................3 Contents ....................................................................................................................... ............................5 Safety note[...]
-
Page 6
Safety notes 6 Safety notes Validity of handbook This handbook is valid for MVG 10, order no.: 208 320. The following notes are import ant for operating the MVG 10 and should be observed under all circumstances. General safety notes The MVG 10 was developed and produced in compliance with the relevant harmonised guidelines, standards and additional[...]
-
Page 7
Safety notes 7 Safety notes Alw ay s observe the VDE safety regulations. Observe the maximum permissible signal feed-in level. Neither DC voltage nor low-frequency AC voltage may be applied to the RF port. Only use fuses with the same cut-out characteristics. The unit is live even when not connected. The unit may only be operated w ith all shieldin[...]
-
Page 8
System description and usage 8 System description and usage The MVG 10 Video Sweep Generator is designed to selectively sweep and measure the forward path and return path of television cable installations without interfering wi th the connected subscribers. The required sweep ranges, channels and signal levels (36…100 dBµV) can be programmed ste[...]
-
Page 9
System description and usage 9 Downstream measurement: 47…860 MHz Head-end (or transfer point) Transfer point (or terminal outlet) Cable installation with return path-capable amplifiers Upstream measurement: 4.0…80 MHz Head-end (or transfer point) Transfer point (or terminal outlet) Cable installation with return path-capable amplifiers Comfort[...]
-
Page 10
System description and usage 10 The spectrum at the head-end can be printed out from the MSK 33 (1) using the print command "Prt 999" on the MVG 10 (1). The command "Clear" clears the spectrum presentation on the MSK 33 (1). Downstream measurement: The MVG 10 (2) is switched from signal generator mode to downstream sweep generat[...]
-
Page 11
Views, connections and controls 11 Views, connections and controls Left-hand side Scart soc ket Right-hand side RS232 socket Power supply Frontal view RF output Display Keypad[...]
-
Page 12
Button functions 12 Button functions The following information explains the operation of the MVG 10. Please use the illustration of the operating concept for assistance. Button Function Display On Off 1. Switch on unit when depressed briefly The upper display appears first, then the lower display with the last function that was set 2. Switch off un[...]
-
Page 13
System settings 13 System settings We recommend checking the factory settings before initial start-up. Please use the operating concept on page 2 for help w ith understanding the operating sequence. Function Button actuation Display Switch on unit when depressed briefly The upper display appears first, then the lower display shortly afterwards with[...]
-
Page 14
System settings 14 Display units ▼ W X + - + System baud rate ▼ setting not possible Transmission readiness ▼ setting not possible Confirm entries Menu Select System.. Accu 100 % Sys Unit dBµV (dBmv, dBm) Sys RTS/CTS on Sys Baudr: 19.2k[...]
-
Page 15
Noise generator 15 Noise generator The noise generator is used for measuring cable installations or sections of cable installations that are not yet occupied with programming. It generates a broadband noise to evaluate the frequency response in the range from 4 MHz to 1 GHz. The bandwidth can be set to 1 MHz or 7/8 MHz. Do not use the noise generat[...]
-
Page 16
Signal generator 16 Signal generator The signal generator is needed to transmit test signals and the screen view from the MSK 33 during "Comfortable Up/Downstream measurement" (see system description). In addition to an internal test picture of coloured bars it has an external modulation input (CVBS/RGB + sound) and is double-sideband mod[...]
-
Page 17
Signal generator 17 Enter transmission frequency directly followed by "Enter" Channel frequency inputs with incorrect entries after the point are not accepted! or 0 9 see above Channel entry - special channels with press · S-Ch first! ▼ W X + - + Enter channel number directly special channels with press · S-Ch first! Also switch b[...]
-
Page 18
Sweep generator 18 Sweep generator The sweep generator is used to sw eep in 10 preset frequency ranges (measuring profiles). The profiles can be programmed to free ranges depending on the channel allocation in the cable network, so that measurement is possible without in terrupting or interfering with programmes. The frequencies and levels can be s[...]
-
Page 19
Sweep generator 19 Enter start frequency ▼ W X + - + Enter frequency directly or 0 9 see above Enter end frequency ▼ W X + - + Enter frequency directly or 0 9 see above 50-kHz steps from one frequency to next in MHz ▼ W X + - + Enter frequency directly or 0 9 see above Step duration from one frequency to next in ms (150 ms – 250[...]
-
Page 20
Sweep generator 20 Clear screen presentation on MSK 33 with "Enter" ▼ X + + + Command to clear spectrum received by MSK33 (MVG10 tracking) ▼ Enter control printout number (up to 3 digits), confirm with "Enter" and run with "Enter" X + + + 0…..9 Command to switch a second MVG10 to stored position "[...]
-
Page 21
Sweep generator operating concept 21 The respective FreqRange (frequency range) can be selected using numbers 0…9. Prt prints out at MSK33 Fkt A sets UScart at MSK33 Fkt B CVBS input at MSK33 Clear clears the screen of MSK33 (Switchover Rec 0/1) (ext. CVBS picture presentation) SwG Level 60.0 dBµV SwG FreqRange nr: 0 SwG FreqRange 0 Sta r t 4. 0[...]
-
Page 22
Channel sweep generator 22 Channel sweep generator The channel sweep generator is used to sweep in 10 preset ranges. The channels can be programmed to free ranges depending on the channel allocation in the cable network, so that measurement is possible without interrupting or interfering with programmes. The channels and signal levels can be select[...]
-
Page 23
Channel sweep generator 23 Enter start channel Special channels with press · S-Ch first! ▼ W X + - + Enter channels directly or 0 9 see above Enter end channel Special channels with press · S-Ch first! ▼ W X + - + Enter channels directly Also switch back to normal channel entry with or 0 9 · S-Ch see above Channel steps (skip a previ[...]
-
Page 24
Channel sweep generator 24 Set standards B/G, D/K, I, M, Mj, H ▼ W X + - + Set the pre-programmed channel ranges to be processed (0…9) ▼ Command to clear spectrum received by MSK33 (MVG10 tracking) ▼ Enter control printout number (up to 3 digits), confirm with "Enter" and run with "Enter" X + + + 0…..9 Command [...]
-
Page 25
Channel sweep generator operating concept 25 The respective ChanRange (channel range) can be selected using numbers 0…9. Setting modulation type Prt prints out at MSK33 Fkt A sets UScart at MSK33 Fkt B CVBS input at MSK33 Clear clears the screen o f M S K 3 3 (Switchover Rec 0/1) (ext. CVBS picture presentation) CSw Level 60.0 dBµV CSw ChanRange[...]
-
Page 26
Recall 26 Recall The "Recall" setting is used to call up the setting stored at addresses 0…9 and start the measuring process. Please use the operating concept on page 2 for help w ith understanding the operating sequence. Function Button actuation Display Switch on unit when depressed briefly The upper display appears first, then the lo[...]
-
Page 27
Technical appendix 27 Technical appendix Technical data Frequency range: 4.0 MHz...1000 MHz Frequency adjustment: 50 kHz Frequency resolution: 62.5 kHz Display: LCD alphanumeric 2 x 16 characters, bar chart; illuminated Adjustment: direct frequency and channel entry; +/- step buttons Sweep ranges: 10 ranges with start/stop and frequency step entry [...]
-