A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Keating Of Chicago 37399, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Keating Of Chicago 37399 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Keating Of Chicago 37399. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Keating Of Chicago 37399 should contain:
- informations concerning technical data of Keating Of Chicago 37399
- name of the manufacturer and a year of construction of the Keating Of Chicago 37399 item
- rules of operation, control and maintenance of the Keating Of Chicago 37399 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Keating Of Chicago 37399 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Keating Of Chicago 37399, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Keating Of Chicago service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Keating Of Chicago 37399.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Keating Of Chicago 37399 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1-800-K EA TI NG www .keatingofchicago.com Users Manual M I RA CLEAN ® GAS G R I D D LE S E R I E S 2000 R EAD AN D SA VE TH I S MAN U AL F OR FUTUR E R E FE R E NCE. Keep this manual for training new personnel. I NTROD UCTIO N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 I N ST ALLA TION I N STR UCTION S . [...]

  • Page 2

    Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. W A RNIN G Improper installation can c ause damage, injury or death. NOT INST ALLED, OPERA TED AND MAINT AINED IN AC[...]

  • Page 3

    INTRODUCTION Instructions in this manual should be read thoroughly before attempting to operate this Miraclean ® Griddle. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel. Service information for Keating equipment has been prepared for use by q[...]

  • Page 4

    GAS CONNECTIONS AND PIPE SIZE The Miraclean ® Griddle requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. The size of the gas supply pipe is very important if the pipe is too small you will have low gas pressure at the Miraclean ® Griddle manifold. Low gas pressure will cause slow recovery and/or delayed ignition. If you have a [...]

  • Page 5

    ASSEMBL Y INSTRUCTIONS FOR GRIDDLE ST AND ON CASTERS (THERE IS NO TOP ON THIS ST AND) PLACING MIRACLEAN ® GRIDDLE IN OPERA TION (When all previous instructions have been completed). Check the serial plate to determine if the burner is set up for the proper type gas before connecting the quick- disconnect or piping from the building gas supply pipe[...]

  • Page 6

    4 LIGHTING INSTRUCTIONS MIRACLEAN ® GRIDDLE (See lighting instructions plate attached to front of MIRACLEAN ® Griddle). Make sure that the main gas valve on the gas supply line to the Miraclean ® Griddle is in the “ON” position. 1. T urn gas valve knob to "pilot" position. 2. Push gas valve knob inwards and push the red spark ignit[...]

  • Page 7

    The Miraclean ® Griddle can be kept in perfect condition by using a razor blade griddle scraper to remove the film that is deposited from the products that have been previously cooked. Eggs, being cooked at a lower temperature, require substantially no scraping; but meat and meat products cooked at a higher temperature, do require scraping. Pancak[...]

  • Page 8

    CLEANING THE MIRACLEAN® GRIDDLE The surface of the MIRACLEAN ® Griddle is very durable and with proper care, following the procedures below , will last many years. A sample of Keating Klenzer , Keating palmetto brush and a 4" scraper are included with each new griddle. 1. Scrape MIRACLEAN ® surface. 2. Clean your Miraclean ® Griddle while [...]

  • Page 9

    PREVENTIVE MAINTENANCE CLEANING CHART A VOID SERVICE CHECKLIST Before calling for service, review this list. It may save you both time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. W ARRANTY REP AIRS Keating’s warranty begins with the date of inst allation. In t[...]

  • Page 10

    8 Figure 6-3 Natural and Propane Gas Heating Systems ITEM DESCRIPTION P ART NUMBER 1 SP ARK IGNITION ASSEMBL Y SEE Item 4, Figure 6-2 2 THERMOPILE 022770 3 PILOT TUBE (1/4”) 007998 4 PILOT ASSEMBL Y 029769 (ALL NA TURAL GAS, 24”-30” 029599 LP , 24”-39” BEF) NA TURAL GAS ORIFICE 007696 PROP ANE ORIFICE 007766 5 BURNER INSERT REFERENCE ONL [...]

  • Page 11

    9 SER VICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified & licensed service company . (Equipment still under warranty requires it.) NOTE: T o correctly and quickly diagnose the system, the chart below should be followed in sequential order . TROUBLE SH[...]

  • Page 12

    SER VICE Servicing should only be performed by qualified & licensed service companies. G A S VA LV E REGULA TOR ADJUSTMENT Recommended gas pressure at manifold (4.0" W .C. Natural gas 10.0" W .C. Propane gas) Adjustment of the gas valve pressure regulator is not normally necessary since it has been preset at the factory . During insta[...]

  • Page 13

    MILLIVOL T CHECK (FOR QUALIFIED SERVICE TECHNICIANS ONL Y ) The millivolt valve is a thermopile self-powered combination gas control. Before checking the millivolt system, the following operations should be performed and observations made: 1. A genuine Keating millivolt thermostat should be used for millivolt operation. 2. The thermost at leads and[...]

  • Page 14

    B. THERMOPILE OUTPUT CHECK (“B” Reading. Thermost at contacts OPEN - Main burner OFF .) 1. Thermopile system - 500 millivolt s minimum. If the minimum millivolt reading is not obtainable, readjust thermopile for maximum millivolt output. If millivolt reading is still below minimum specified, replace thermopile. C. THERMOST A T RESIST ANCE CHECK[...]

  • Page 15

    13 GAS GRIDDLE WIRING DIAGRAM CONTROL PANEL THERMOSTAT ON/OFF SWITCH[...]

  • Page 16

    L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp®, Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after Jun[...]

  • Page 17

    15 SER VICE INFORMA TION If you hav e a service related question call 1-800-KEA TING. Please state the nature of the call; it will ensure speaking with the appropriate person. Hav e your serial and model number av ailable when ordering parts. KEA TING OF CHICA GO, INC. 8901 W . 50th Street, McCook, Illinois 60525-6001 Phone: (708) 246-3000 F AX: (7[...]