A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Kidde 820-0898, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kidde 820-0898 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Kidde 820-0898. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Kidde 820-0898 should contain:
- informations concerning technical data of Kidde 820-0898
- name of the manufacturer and a year of construction of the Kidde 820-0898 item
- rules of operation, control and maintenance of the Kidde 820-0898 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kidde 820-0898 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kidde 820-0898, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kidde service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kidde 820-0898.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Kidde 820-0898 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
For your convenience, write down the following infor mation. If you call our Consumer Hotline, these are the first questions you will be asked. 9 V olt Battery Battery Operated Smoke Alarm with “HUSH” Control to temporarily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’ s home safet[...]
-
Page 2
This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioac- tive material (see section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt fr om any regulatory r equirements. Do[...]
-
Page 3
• Locate an alarm in every room wher e electrical appliances are operated (i.e. portable heaters or humidifiers). • Locate an alarm in every room wher e someone sleeps with the door closed. The closed door may prevent an alarm not located in that room fr om waking the sleeper . • Smoke, heat, and combustion products rise to the ceiling and sp[...]
-
Page 4
• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or r oom is more than 30 ft (9.1 m) long. • Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft (0.9m)of the highest point (measured horizontally). NFP A 72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft (.[...]
-
Page 5
• In very humid areas. Moisture or steam can cause nuisance alarms. • In insect-infested areas. • Smoke alarms should not be installed within 3 ft (.9m) of the following: The door to a kitchen, the door to a bathroom con- taining a tub or shower , forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or[...]
-
Page 6
1. Remove the mounting plate fr om the back of the alarm by hold- ing the mounting plate and twisting the alarm in the direction indicated by the “OFF” arrow on the alarm cover . 2. T o insur e aesthetic alignment of the alarm with the hallway or wall, the “A” line on the mounting plate should be parallel with the hallway when ceiling mount[...]
-
Page 7
NOTE: THE T AMPER RESIST PIN WILL HA VE TO BE REMOVED IN ORDER TO CHANGE THE BA TTERIES. USE LONG NOSE PLI- ERS TO PULL THE PIN OUT OF THE HOLE. IT IS NOW POSSI- BLE TO REMOVE THE ALARM FROM THE MOUNTING PLA TE. 8. After installation, test your alarm by depressing and holding down the test button for at least 5 seconds. This should sound the alarm.[...]
-
Page 8
alarm or ignite combustible materials and start a structure fir e. TEST THE ALARM WEEKL Y TO ENSURE PROPER OPERA TION. Erratic or low sound coming from your alarm may indicate a defective alarm, and it should be returned for service (see section 12). NOTE: WEEKL Y TESTING IS REQUIRED. 5. NUISANCE ALARMS Smoke alarms are designed to minimize nuisanc[...]
-
Page 9
Alkaline type: ENERGIZER 522; DURACELL MN1604, MX1604; GOLD PEAK 1604A; P ANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA) Lithium type: UL TRALIFE U9VL-J NOTE: WEEKL Y TESTING IS REQUIRED. W ARNING!! USE ONL Y THE BA TTERIES SPECIFIED. USE OF DIFFERENT BA TTERIES MA Y HA VE A DETRIMENT AL EFFECT ON THE SMOKE ALARM. CLEANING YOUR ALARM YOUR ALA[...]
-
Page 10
cles (associated with slow smoldering fires) sooner than ioniza- tion alarms. Home fires develop in dif ferent ways and are often unpredictable. For maximum pr otection, Kidde recommends that both Ionization and Photoelectric alarms be installed. • A battery powered alarm must have a battery of the specified type, in good condition and installed [...]
-
Page 11
• Practice a fire drill at least every six months, including fire drills at night. Ensure that small childr en hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency . Y ou may not be able to reach your childr en. It is important they know [...]
-
Page 12
9. NRC INFORMA TION Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products. The radioactive element is safely contained in the chamber and requir es no adjustments or maintenance. This smoke alarm meets or exceeds all government standards.[...]
-
Page 13
11. CAUTION (AS REQUIRED BY THE CALIFORNIA ST A TE FIRE MARSHAL) “Early warning fire detection is best achieved by the installation of fire detection equipment in all r ooms and areas of the household as follows: A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of the bedrooms), and heat or smoke detectors i[...]
-
Page 14
FIVE YEAR LIMITED W ARRANTY KIDDE Safety warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase. The obligation of KIDDE Safety under this warranty is limited to repairing [...]
-
Page 15
820-0898 REV . B SIGNALING LISTED U L 0916 Guía del usuario de alarmas contra humo Para el modelo: 0916 Alarma contra humo a batería de 9 voltios con control de silenciador , que permite silenciar temporalmente alarmas molestas. Gracias por comprar esta alarma contra humo, es parte importante del plan de seguridad de su hogar . Puede confiar en q[...]
-
Page 16
Esta alarma detecta productos de combustión usando la técnica de ionización. Contiene 0.9 microcurios de americio 241, que es un material radiactivo (consulte la Sección 9). Se distribuye bajo licencia de NRC de EE.UU., Nº 32-23858-01E. Fabricada en conformidad con los criterios de seguridad de NRC de EE.UU. en 10 CFR 32.27. El comprador está[...]
-
Page 17
• Al instalar una alarma en el cielo raso, colóquela a una distancia mínima de 4 pulg. (10 cm) de la pared lateral (consulte la Figura 1). • Al instalar la alarma en la pared, use una pared interior con el bor de superior de la alarma a un mínimo de 4 pulg. (10 cm) y un máximo de 12 pulg. (30.5 cm) bajo el cielo raso. (Consulte la Figura 1)[...]
-
Page 18
el extremo superior de la alarma a un mínimo de 4 pulg. (10cm) y un máximo de 12 pulg. (30,5cm) bajo el cielo raso (consulte la Figura 1). Si no está seguro de cuál es el aislamiento de su casa rodante, o si observa que las paredes externas y el cielo raso están calientes o fríos, instale la alarma en una pared interna. Para una protección m[...]
-
Page 19
¡PRECAUCIÓN! SI NO SE MANTIENE PRESIONADO EL ENGANCHE DE RETENCIÓN INDICADOR DE BA TERÍA EN EL COMP ARTIMIENTO CORRESPONDIENTE, LA PUER T A DEL COMP ARTIMIENTO NO SE CERRARÁ Y LA UNIDAD NO SE CONECT ARÁ AL SOPORTE DE MONT AJE. 6. Se pr opor cionan mar cas de alineación en el borde de la placa de ajuste y de la alarma. Después de instalar la[...]
-
Page 20
CONTROL DE SILENCIADOR: La función de silenciador tiene la capacidad de insensibilizar el circuito de la alarma durante aproximadamente 7 minutos. Esta función sólo se debe usar cuando una condición de alarma conocida, como humo proveniente de la cocina, activa la alarma. La alarma contra humo se insensibiliza presionando el botón de silenciad[...]
-
Page 21
USE SÓLO LAS SIGUIENTES BA TERÍAS DE 9 V P ARA REEMPLAZAR LAS BA TERÍAS DE LA ALARMA CONTRA HUMO. De carbón y cinc: EVEREADY 216 Ó 1222; GOLD PEAK 1604P Ó 1604S Alcalina: ENERGIZER 522; DURACELL MN1604, MX1604, GOLD PEAK 1604A P ANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, y 6LR61(GA) De litio: UL TRALIFE U9VL-J NOT A: ES NECESARIO HACER PRUEBAS SEM[...]
-
Page 22
baterías y los circuitos de alarma estén en buenas condiciones de funcionamiento. • Las alarmas contra humo no pueden dar la alarma si el humo no llega a ésta. Por lo tanto, es posible que estas alarmas no detecten incendios que se inicien en chimeneas, paredes, techos, al otro lado de una puerta cerrada o en otr o piso. • Si la alarma está[...]
-
Page 23
H ay situaciones en las que puede que una alarma contra humo no sea efectiva para proteger contra un incendio, según lo establecido en la Norma 72 de la NFP A. Por ejemplo: a) fumar en la cama; b) dejar a los niños solos en la casa; c) limpiar con líquidos inflamables, como gasolina. 9. INFORMACIÓN DE NRC Las alarmas contra humo de ionización [...]
-
Page 24
GARANTÍA LIMIT ADA DE CINCO AÑOS KIDDE Safety garantiza al comprador original que la alarma contra humo adjunta (pero no la batería) estará libre de defectos de material y mano de obra o de diseño en condiciones normales de uso por un período de cinco años a partir de la fecha de compra. La obligación de KIDDE Safety de acuerdo con esta gar[...]