Go to page of
Similar user manuals
-
Ventilation Hood
Kobe Range Hoods CH0042SQB (42")
36 pages 2.17 mb -
Ventilation Hood
Kobe Range Hoods CH0042SQB
36 pages 2.18 mb -
Ventilation Hood
Kobe Range Hoods CH0148SQB
36 pages 0.77 mb -
Ventilation Hood
Kobe Range Hoods CH9642SQB
35 pages 1.27 mb -
Ventilation Hood
Kobe Range Hoods CH9142SQB
27 pages 2.51 mb -
Ventilation Hood
Kobe Range Hoods CH7748SQB
108 pages 2.2 mb -
Ventilation Hood
Kobe Range Hoods CX1830GS-8
25 pages 0.86 mb -
Ventilation Hood
Kobe Range Hoods RA3836SQ
24 pages 0.88 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Kobe Range Hoods CH0142SQB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kobe Range Hoods CH0142SQB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Kobe Range Hoods CH0142SQB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Kobe Range Hoods CH0142SQB should contain:
- informations concerning technical data of Kobe Range Hoods CH0142SQB
- name of the manufacturer and a year of construction of the Kobe Range Hoods CH0142SQB item
- rules of operation, control and maintenance of the Kobe Range Hoods CH0142SQB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kobe Range Hoods CH0142SQB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kobe Range Hoods CH0142SQB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kobe Range Hoods service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kobe Range Hoods CH0142SQB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Kobe Range Hoods CH0142SQB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
KOBE Brand Range Hood Model No.: CH013 0SQB CH013 6SQB CH014 2SQB CH014 8SQB CH-101 SERIES – 18” HEIGHT I N S T A L L A T I O N I N S T R U C T I O N S A N D O P E R A T I O N M A N U A L[...]
-
Page 2
[...]
-
Page 3
- READ AND S A VE THES E INSTRUC T IONS - CONT ENTS IM PORTANT SAF ETY I NSTRUC TIONS.................................................................................... 1 COM PONENTS OF PA CKAG E ................................................................................................. 3 IN STAL LATI ON .....................................[...]
-
Page 4
1 IMPORTANT SAFETY INSTRUCT IONS - PLEASE READ T HIS SECT I O N CAR EFUL L Y BEFORE INSTALLATION - WARNI NG : TO REDUCE T HE RISK OF F IRE, ELECT RIC SHOCK OR PERSONAL INJUR Y , OBSERVE THE F OLLOWING: 1) Installation and ele ctrical wirin g m ust be done b y qualified profess i onals an d i n accordance with all applicable codes a nd st andards, i[...]
-
Page 5
2 W hat to Do In The Event Of a Range T op Grease Fire - SMOTHER FLAMES with a c lo se fitting lid, cookie sheet, or m e tal tra y , and then tu rn off the burn er . KEEP FLAMMABLE O R COMBUST IBLE MA TERIAL A W A Y F ROM FLAMES. If the fl ames do no t g o out i mm edi a tel y , EV ACUA T E THE AR EA AND CALL T HE F IR E DEP AR T MENT or 91 1. - NE[...]
-
Page 6
3 COMPONENTS OF PA CKAGE (Must keep a ll materi al for returns or re funds) O P T I O N A L R E C I R C U L A T I N G K I T A L S O A V A I L A B L E . F O R M O R E I N F O R M A T I O N , P L E A S E V I S I T O U R W E B S I T E W W W . K O B E R A N G E H O O D S . C O M O R C O N T A C T K O B E R A N G E H O O D S A T ( 6 2 6 ) 3 5 0 [...]
-
Page 7
4 INS T ALLATION PLEASE READ ENTIRE INSTRUCT ION BEFORE PROCEEDING Calculatio n before Installat ion To cal culate installation , p l ea se refer to Table 1. (All calcu la tion in inches.) - FO R UNDER T HE CABINET - T ABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standa rd: 36”) C = Preferred Height of Counter Top to [...]
-
Page 8
5 SAFETY WA RNIN G HOOD MAY H AVE VER Y SH ARP E DGES; PL EASE W E AR PROT ECT IVE G LOVES IF REMOVING ANY PART S FOR INST ALLING, CLEA N ING OR SERV ICING. N OT E: USIN G ELE CTRICA L SCREWDRIVERS MA Y CAU SE DAMAGE TO THE HOODS. I nst allation T ab le of C ontent s UN DE R THE CA BI N ET IN ST A LLA T IO N ........................................[...]
-
Page 9
6 UNDER T HE CA B INE T INS T A LLAT ION Preparatio n Before Installat ion NOTE: TO AVOID DAM A GE TO YOUR HOOD, PREVE NT DEBRIS FROM ENTERING THE VENT OPENING. • Decide th e lo cation of the ve nting p i pe from t he hood to the outside. Refer to Figure 1. • A s t ra i g h t , s h o r t v e n t ru n w i l l a l l o w t h e h o o d t o p e rf o[...]
-
Page 10
7 Ductwork Installat ion 7. Use 8” a luminum o r st eel p ipe ( fo llow bu ildi ng codes in your a rea) to c onnect the duct i ng transi tion on the hood to the duct w ork above. Use duct tape to seal and secure joints as shown in Figure 5. Wiring to Po wer Supply S A F E T Y W A R N I N G TO PREVENT T HE RISK O F ELECTRICA L S HOCK OR INJURY , A[...]
-
Page 11
8 15. I nstall he ati n g l amps ( not p r ovi ded), 120 Volt s 25 0 Watt s m ax. e ach. 16. T urn powe r ON in control panel. Check all lights and fan operation. 17. M ake sure to leave this manual for t he hom eo w ner Figure 8[...]
-
Page 12
9 ST AND A LO NE INST A LL ATION * * * F ol l o w th e se i ns t a l l a ti o ns o n l y i f i n s t a l l i n g wi t h a n o p t i o n al d u c t c o v e r : Preparatio n Before Installat ion NOTE : TO AVOID DAM AGE TO YOUR HO OD, PRE VENT DEBRI S FROM ENT E RIN G TH E VENT OP E NIN G. • Decide the location of the venting pipe f rom the hood to [...]
-
Page 13
10 2. Alig n hoo d -m oun ting b rac ket to the t w o screw s on the wall and hook hood in t o p la ce. Ti ghte n scr ews to s ec u re hood t o t he wall . 3. For sa f et y purp ose, extr a knocko ut holes on th e back of the ho od are provi ded fo r a m o r e se cure inst all ati o n. Knoc k out a s m any hole s as need ed an d secur e wit h scr e[...]
-
Page 14
11 Duct Cover Installat ion 5. Use 8” a luminum or steel pipe (follow building codes i n y ou r area) to co nnect the ducting transition o n the hood to the ductwork abo ve . Use duct t ape to seal and secure joints as show n in Figu r e 15 . Sl i de t he du ct cover onto t he hoo d. 6. Use 3 /1 6 ” x 3 /8” scr ews (pr o vi ded) to att a ch d[...]
-
Page 15
12 OPER A TING INSTRU CTIONS This KOBE h ood i s equipped with touch-sensor screen and fe atures 3 m i nu te d el ay shu toff, powerful centrifug al squirrel cage with baff le fil ters, b right 12- volt 20-watt ha lo gen li gh ts a n d heatin g lam p cap abili ty (heating lam ps not i ncluded). The touch-sensor screen has Hea t La mp Con tr ol , Li[...]
-
Page 16
13 Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control s i g n o n c e , t h e symbol f l a shes and a f t e r 3 m i n u t e s , the ho o d w i l l t u r n o f f l e a v i n g o n l y t h e sign li t . Sp e e d C o n t rol : • There are four speeds: QuietM ode™, Low, Medium, and High. To act iv ate the speed, touch the[...]
-
Page 17
14 M A INTEN A NCE SAFETY WA RNIN G NEVER PUT YOUR HAND INTO AREA HOU SIN G T HE F AN WHILE THE F AN I S OPERAT ING. For opt imal op eration, clea n range hood surface an d stainless steel baff le filters regularly. Cleaning Hoo d Surface CAUTI ON : NEVER USE ABRASIVE CLE ANERS, PADS, OR CL OTHS. Regular care will help prese rve the appearance of t[...]
-
Page 18
15 Cleaning Stainless Oil T unn e l, Baf fle Filters and Spa cers CAUTI ON : DR AIN OIL BEFORE RES IDUE CAN OVERFLOW. 1. Re move the baf fle filter (reverse the order of baffle installati on). 2. Car efully r em o ve oil tunnel. 3. Di scard oil an d residue. 4. W ash oil tunnel, baffle filters and spacers with w a r m soapy water. 5. Dry thoroughly[...]
-
Page 19
16 SPECIFICA TIONS CH0130SQB / 30“ CH0136SQB / 36“ CH0142SQB / 42“ M O DEL / S IZE CH0148SQB / 48“ COLOR #304 C ommercial Grade S tainl e ss S teel CONSUMPTI O N / AM PERE 900W / 8 A VOL T AGE 120V 60Hz NUM B ER OF MOT ORS 1 DESIGN 18 Gauge Seamless / Satin Finish F AN TYPE: CENTRIFUGAL Squ irrel C age EXHAUST T o p T ransition Rect a ngula[...]
-
Page 20
17 ME A S UREMENTS & DIA G R A M S *** In c h measurements co nverted from millimete r. In c h meas urem e nts are e stimated. - F O R U N D E R T H E C A B I N E T - MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 / 8 " ( 7 9 . 5 ) 1 8 " (4 5 7 ) 2 4 " ( 6 1 0 ) 1 2 "[...]
-
Page 21
18 - F O R U N D E R T H E C A B I N E T – ( C o n t . ) 2 - 5 / 8 " ( 6 6 ) 1 - 1 / 4 " ( 3 2 ) 6 - 1 / 2 " ( 1 6 5 ) 5 - 5 / 8 " ( 1 4 3 ) 1 0 - 3 / 4 " ( 2 7 3 ) 8 - 5 / 8 " ( 2 1 9 ) 1 3 - 3 / 8 " ( 3 4 0 ) 1 2 " ( 3 0 5 ) 1 - 1 / 4 " ( 3 2 ) 2 - 5 / 8 " ( 6 6 ) 1 / 2 " ( 1 2 )[...]
-
Page 22
19 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " (4 5 7 ) 1 8 - 7 /8 " ( 4 8 0 ) 1 9 - 1 / 3 " (4 9 1 ) 1 - 1 / 4 " ( 3 2 ) 1 2 " ( 3 0 5 ) 6 " ( 1 5 2 . 5 ) 7[...]
-
Page 23
20 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – (Con t.) 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " ( 4 5 7 ) 3 0 " ( 7 6 2 ) (1 2 " ) ( 3 0 5 ) 1 2 " ( 3 0 5 )[...]
-
Page 24
21 Hood- Mounting Bracket 1" ( 2 5 .4) 4 " (1 0 2 ) 1 /2 " (1 3 ) 1 /3 " (8 . 5 ) 3 /1 6 " (5 ) 1/ 4" ( 6 .5 ) 1 1 /1 6 " (1 7 . 5 ) 1 - 3 /8 " (3 5 ) 7 - 1/ 2" ( 1 9 0.5 ) 6" ( 1 5 2) BAFFLE F ILTER & STAINLESS STEEL SPACERS 4 8 " HO O D 4 2 " HOO D 3 6 " HO O D 3 0 " HOO D[...]
-
Page 25
22 P A RTS LIST MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB BODY COMPONENT S NO. DESCRIPTI ON MODEL/SIZE PART NO. 1 Hood Casing CH101-1 2 Ducting Tran si tion CH101-2 3 Screws (3/16 ” x 3/8 ”) C H101-3 4 Blower Assembly C H101-4 5 Field W iring Bo x Co v er CH101-5 6 Field W iring Bo x CH101-6 7 Heat L am p Socket CH101-7 8 Screws (3/16 ?[...]
-
Page 26
23 1 2 3 4 5 9 3 8 1 0 1 1 6 1 2 1 3 1 4 1 7A 1 6 1 8 1 9 2 0 2 1 7 1 7B 1 7 1 5 2 2 2 3 Optional Duct Cover ( Sold Separately) 2 4 3[...]
-
Page 27
24 Blower Assembly NO. DESCRIPTION MODEL / SIZE PA RT NO. 4.1 Screws (3/16 ” x 3/8”) CH101-4.1 4.2 Air Flow Grill CH101-4.2 4.3 Left Locknut CH101-4.3 4.4 Left Squirrel Cage CH101-4.4 4.5 Motor CH101-4.5 4.6 Ri ght Squirrel Cage CH101- 4.6 4.7 Ri ght Locknut CH101- 4.7 4.8 Air Chamber CH10 1-4. 8 4 .8 4 . 7 4 .6 4 . 5 4 . 4 4 .3 4 .2 4 .1[...]
-
Page 28
25 Electrical Assembly NO. DESCRIPTION M ODEL / SIZE PART NO. 21.1 Bolt CH10 1-21 .1 21.2 Elect rical Box CH10 1-21 .2 21.3 Screws (3/16” x 3/8”) CH10 1-21 .3 21.4 Pow er Boa rd CH10 1-21 .4 21.5 Elect rical Box Cover CH10 1-21 .5 21.6 Setup Boar d CH10 1-21 .6 21.7 Screws (3/16” x 3/8”) CH10 1-21 .7 21.8 Capaci tor CH10 1-21 .8 21.9 Tra ns[...]
-
Page 29
26 Switch Assembly NO. DESCRIPTION MODEL / SIZE PA RT NO. 20.1 Screen Support CH10 1-20 .1 20.2 Touch Scr een CH10 1-20 .2 20.3 Sw i tch Box CH10 1-20 .3 20.4 Sw i tch Boar d CH101-2 0.4 20.5 Sw i tch Box Cover CH10 1-20 .5 20.6 Screw s (1/8 ” x 1/2”) CH10 1-20 .6 2 0 .1 2 0 .2 2 0 .3 2 0 .4 2 0 .5 2 0 .6[...]
-
Page 30
27 CIRCUIT DIAGRAM MODEL NO.: CH0130SQB CH0136SQB[...]
-
Page 31
28 MODEL NO.: CH0142SQB CH0148SQB[...]
-
Page 32
29 DIS CL AIMER 1. CAREFUL LY INSPECT ALL I T EMS FOR DAMAGES BEFO RE ACCEPTING DELIVERY. NOT E A NY D A MAGES O N T HE F REI GHT BI L L OR EXPRESS RECEIPT. REQUES T NAME A ND SIGNATURE O F T HE CA RRIER’S AGENT A ND KEEP COPY T O SUPPORT YOUR CLAIM. Upon acceptance of ite m s, owner assumes responsibility for its safe arrival. Damages should b e[...]
-
Page 33
30 WA RRANT Y WA RRANT Y CERTIFICA T E KOBE Rang e Hoods, Inc. w arr ants all produc ts manufactur ed or sup plied by i t to b e free fro m defect s in w or km a nshi p and materi als. Its obligations pursuant to th i s warranty are limited to a perio d of two year s from th e da te of p urchase and to the repair or repla cem e nt at its optio n a [...]
-
Page 34
31 h) fo r da m a ge b y or re su l ting f rom atte m p ted repairs conducted by anyone other than our Aut horized Service Agent. 3) T he purcha ser sh all be r espo nsible fo r an y expenses i nvol ved i n m aki ng the r ang e hood r eadily accessible for servicing a nd where th e ra nge h ood i s i nstalled ou tside th e m ai n sal es t erritory [...]
-
Page 35
32 PRODUCT REGISTRA TION Regis ter Your Product! Any covere d failure occurrin g within t wo year s of original purch ase arising from defe ctive workmanship or m ate rial in m anu factur e will be r epaired o r at our option t he unit will be repla ced free of ch arge by an authorized KOBE Range Hood s Agent or KOBE Range Hoods a s applicable. Kee[...]
-
Page 36
KOBE Range Hoo ds 10505 Valley Blvd Suite # 302 El Monte , CA 91731 USA http:// www.KOB ERa ngeH oods.c om This KOBE hood i s m ade fo r use i n the US A a nd CANADA o nl y . W e do not recomm end usi ng thi s hood ove rseas as t he pow er suppl y may not be com p ati bl e and may vi olate the el ectr i cal cod e of that country. Us ing a KOBE hood[...]