Go to page of
Similar user manuals
-
Ventilation Hood
Kobe Range Hoods IN2730SF
23 pages 0.96 mb -
Ventilation Hood
Kobe Range Hoods CH2742SQB
102 pages 2.11 mb -
Ventilation Hood
Kobe Range Hoods CH0042SQB
36 pages 2.18 mb -
Ventilation Hood
Kobe Range Hoods CH7748SQ
18 pages 1.46 mb -
Ventilation Hood
Kobe Range Hoods CH7742SQB
108 pages 2.2 mb -
Ventilation Hood
Kobe Range Hoods CH7742SQ
18 pages 1.46 mb -
Ventilation Hood
Kobe Range Hoods CH7748SQB
108 pages 2.2 mb -
Ventilation Hood
Kobe Range Hoods CH0130SQB (30")
36 pages 0.8 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Kobe Range Hoods CH7636SQB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kobe Range Hoods CH7636SQB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Kobe Range Hoods CH7636SQB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Kobe Range Hoods CH7636SQB should contain:
- informations concerning technical data of Kobe Range Hoods CH7636SQB
- name of the manufacturer and a year of construction of the Kobe Range Hoods CH7636SQB item
- rules of operation, control and maintenance of the Kobe Range Hoods CH7636SQB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kobe Range Hoods CH7636SQB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kobe Range Hoods CH7636SQB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kobe Range Hoods service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kobe Range Hoods CH7636SQB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Kobe Range Hoods CH7636SQB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
K O B E B r a n d R a n g e H o o d Mod el No. CH76 30SQB (30”) CH7636SQB (3 6”) CH7642SQB (4 2”) CH7648SQB (4 8”) CH-176 SERIES – 10” HEIGHT INST ALLA TION INSTRUCTIONS AND OPERA T ION MANUAL[...]
-
Page 2
- READ AND SA V E T HESE INST RUCTIONS - CONT ENTS IMPOR T ANT SAFETY INSTRUC TIONS .........................................................................1 COMPONEN TS OF P A CK AGE .......................................................................................3 INST ALL A TION ............................................................[...]
-
Page 3
1 IMPORT A NT SAFET Y INST RUCTIONS - PLEASE READ T HIS SECT ION CARE F UL L Y BEFORE INST A LL A TION - W A RNI NG: TO REDU CE T HE RISK OF FIRE, ELECTRIC SH OCK O R PE RSONA L I N J UR Y , OBSERVE T HE FOLLOWIN G: 1) Installation a nd el e ctrical wiring mu st be done by q ualif i e d p rofessionals and in accordance with all applicable codes and[...]
-
Page 4
2 W hat to D o In Th e Event O f a Range T op Grease Fire • SMOTHER FL AMES wit h a close f itting lid, cook i e sheet , or metal tray , and then turn of f t h e b urner . KEEP FLAMM AB LE OR COM BUSTIBLE MA TE R IAL A WA Y FRO M FLA M E S. If the f lam e s do no t go out immediately , E V ACUA TE TH E AREA A ND CA LL THE FI RE DEP A RTM ENT or 9[...]
-
Page 5
3 COMPONENTS OF P ACKAGE (Must keep all material for re t urns or refunds) Range Hood Box Duct Co ver Box (Sold Se parately) {A} KOBE Range Ho od {B} W arranty Regis tratio n Card {C} In s truct ion Manual {D} Baffle F ilter -- 2 (30”, 36”, 42”) -- 3 (48”) {E} Stain le ss Steel S pacer -- 0 (30”) -- 1 (36”) -- 3 (42”) -- 2 (48”) {F}[...]
-
Page 6
4 INST ALL A T I ON PLEASE READ ENTIRE INSTRUCT IONS BEF ORE PROCEEDING Calculatio n before Inst a llation T o ca lculate i n stalla t ion, please refer to T ABLE 1 or T AB L E 2. (All calculation i n inches.) - FO R UNDER T HE CA B INET - T A BLE 1 A = Height of Floor to Ceili n g B = H e ight o f Floor to Counter T op (S tandar d : 36”) C = Pre[...]
-
Page 7
5 SAFETY WA RNIN G H O OD MA Y HA V E VE R Y S HA RP EDGE S; PLEA S E WEA R P ROTECT IV E GLOVES IF I T IS N E CESS A RY TO REMOVE A NY P A RT S FO R INS T A LL ING , CLE ANIN G O R SERVICI NG . N O TE : BE C A REFUL WHE N U SING ELE CTRICA L SCRE WDRI V ER, D AMA GE TO THE H OO D MA Y OCCUR. Installation C onten ts UNDER THE CABINE T INST ALL A TI[...]
-
Page 8
6 UNDER T HE CA B INET INS T ALLA T ION P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: TO A VOI D DA M A GE T O YOUR HOOD, PREVENT DEBRI S FROM ENTERING THE VENT OPENI NG . • Decide the location of the v e nting pipe f r o m the hood to the outside. Refer to Figure 1. • A straight, short vent run will allow the hood to perform [...]
-
Page 9
7 4. Draw electrical wires through c a binet acces s o p ening. 5. From inside of the hood, p l a ce s crew (not provided) into the exact center of each knockout hole and secure to cabinet bottom. Once all mounting screws are in p lace, f i n ish tightening screws u n til secure. CAUTI ON : MAKE SUR E THE H O OD IS SECURE BEFORE R E LEA SING . 6. F[...]
-
Page 10
8 A c c e s s o r i e s 9. Drop o il tunnel into recess support near re ar of hood. Refer to Figure 6. 10. Install baf f le f ilters a nd st a inless sp acer(s). Refer t o Mea sur e m ents and Dia g r a m s on pa ge 22 f or baffl e fil ter and stai nless spac e r pla ceme nt. Ang le baf f le filte r towar d ba ck o f hood . Push baffle filter u[...]
-
Page 11
9 ST AND ALONE I N ST ALLA T ION *** This i n stalla t ion only applies i f installing wit h the CH1 1 20DC duct cover . P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: T O A VOID DA M A GE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENI NG . • Decide the location of the venting pipe f r o m the hood to the outsid e . (F[...]
-
Page 12
10 1. Using refere n ces in T A BLE 1 and M e asu rements and Diagrams o n pages 19-21, mark th e le ve ling point of t he hood. Position two mo unting screws (not provided) on the wall, leaving 1/8” sp a ce away from the wall. 2. Pu nctur e the knockout wire acces s ho le at the back of the hood and draw the ele ctri ca l wires through as shown [...]
-
Page 13
11 D u c t C o v e r I n s t a l l a t i o n 6. Mark the p osition of t he inner duct cover- mounting bracket {J} (provided). Us e reference E from T ABLE 2 a nd M e asu rements and Diagrams on p a ge 20-21. Attach and sec ure inner du ct cover- mo unting bracket {J} with two scr e ws (not p rovided) to the wall. Refer to Figure 15. NOTE: Inner duc[...]
-
Page 14
12 F i n a l A s s e m b l y 14. T urn p ower O N in control panel. Check all light and fan operation. 15. Make su re to leave th is manual for the homeowner . Figure 19[...]
-
Page 15
13 OPERA T ION I NST RUCT IONS This KOBE hoo d is equi pped with six electronic contr ols, two powerful ce ntr i fug al squirrel cages with sta i nless stee l oil t unnel, sta i nless steel b aff l e filters an d sp ace r(s), and bright 1 2- vol t 20-watt halogen lights (2 for 30” & 36” and 3 f or 42” & 48”). The six electronic butt[...]
-
Page 16
14 Figure 2 1 T ur ning Fan OFF: The 3-Minute Delay fun ction w il l onl y turn off fans. The light settings w il l no t be affected by the del ay function. 3-Min ute Delay - Press Pow er Control (On/Of f) button once , the L ED lig ht f or the act i ve spee d will flash and fa ns will shut off afte r 3 m i nu tes. - During this 3-m i nu te dela y [...]
-
Page 17
15 MAINT ENA NCE SAFETY WAR NIN G NEVER PUT YOUR HA ND INTO AREA HOU SI NG T HE F AN WHILE T HE F AN IS OPERA T I NG . For optimal operation, clean ran g e hood and all baf f le/spacer/ f ilter/oil tunnel/oil cont a iner regul a rly . T o Clean Hood Surface CAUTI ON : NEVER USE A BR A S I V E CLEAN ERS , P A DS , OR CLOTHS. *** Regular care will he[...]
-
Page 18
16 T o Replace Light Bul b CAUTI ON : HALOGEN LIGH T UNIT MA Y BE HOT! W AI T UNTIL UNI T IS COOL. 1. Make sure all controls are of f, and range hood is unp lugged. 2. Place a flat- h ead screwdriver betwe e n light cover an d housing to remove cov e r . 3. Gently pu ll d efect[...]
-
Page 19
17 SPECIFICA T IONS MODEL / SIZE CH76 30SQB / 30” CH76 36SQB / 36" CH76 42SQB / 42” CH76 48SQB / 48” COLOR #304 Commercia l Grade S tainles s S t eel CONSUMP T ION / AMPERE CH76 30SQB – 300 W / 3A CH76 36SQB – 300 W / 3A CH76 42SQB – 300 W / 3A CH76 48SQB – 300 W / 3A VOL TA GE 120V 60 Hz NUMBER O F MO TORS 2 DESIGN Seamles s / S[...]
-
Page 20
18 MEASUREMENT S & DIAGRAMS A ll ( ) are in m illimeter . A ll inch measurement s are converted from millim e ters. Inch measurements a re esti mated. - FO R UNDER T HE CA B INET - MODEL NO : CH76 30SQB CH7636SQB CH7642SQB CH7648SQB[...]
-
Page 21
19 A ll ( ) are in m illimeter . A ll inch measurement s are converted from millim e ters. Inch measurements a re esti mated. - FO R S T AND ALONE (WITH O P T I ONAL DUCT CO VER) - MODEL NO : CH76 30SQB CH7636SQB CH7642SQB CH7648SQB[...]
-
Page 22
20 Rear Knocko ut Holes 2 4 " ( 6 0 8 ) f o r 4 2 " 3 0 " ( 7 6 0 ) f o r 4 8 " 1 8 " ( 4 5 6 ) f o r 3 6 " 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 1 2 " ( 3 0 4 ) f o r 3 0 " 2" (51) 4 " ( 1 0 2 )[...]
-
Page 23
21 Hood-Mounting Bracke t DUCT COVER-MOUN T I NG BRACKET I nn er Duct Cover-Mounti ng B r a cket Outer Duct C o ver- Mounting Bracket 1 1 - 3 / 4 " ( 2 9 8 ) 1 - 3 / 1 6 " ( 3 0 ) 1 - 1 / 4 " ( 3 2 . 5 ) 8 - 5 / 8 " ( 2 1 9 ) 8 - 5 / 8 " ( 2 2 0 ) 1 1 - 3 / 4 " ( 2 9 8 ) 7/8" ( 22) 1/8" ( 4.5) 3 - 1 / 8 "[...]
-
Page 24
22 BA F FL E FIL T ER & ST AINLESS ST EEL SP ACERS 30 ″ H 00 D 42 ″ H 00 D 3 6 ″ H 00 D 48 ″ H 00 D[...]
-
Page 25
23 P ART S LIST M ODE L N O.: CH 7 6 30SQB CH 7 636 SQB CH 7 642 SQB CH 7 648 SQB Body Compo nents NO. DESCRIPTION MODEL/SIZE P ART NO. 1 Screws (3/16” x 3/8”) CH176- 1 2 Hood Ca sing CH176- 2 3 Hood- Mounting Bracket CH176- 3 4 Screws (3/16” x 3/8”) CH176- 1 5 S tai nless S teel Oil T unnel CH176- 4 6 Blower Asse mbly CH176- 5 7 Hal ogen L[...]
-
Page 26
24 3 2 1 4 5 6 7 1 0 2 1 9 1 5 1 6 1 8 1 9 1 7 1 4 1 3 1 1 1 2 B 1 2 C 1 2 1 2 A 2 0 2 2 8[...]
-
Page 27
25 Blower Assembly NO . D ESCR IP TI ON MOD EL /SI ZE P ART NO . 1 Ai r C ha mber CH 17 6- 6 .1 2 Sc re w Ca p CH 17 6- 6 .2 3 L eft S qu ir rel C age CH 17 6- 6 .3 4 L eft L o ck nu t CH1 76 -6 .4 5 Ai r Flo w G rill CH 17 6- 6 .5 6 Sc re ws ( 3 /16 ” x 3/ 8” ) CH 17 6- 6 .6 7 R i gh t Lo ck nu t CH 17 6- 6 .7 8 R i gh t Squir rel C age CH1 7 [...]
-
Page 28
26 Electrical Assembly NO . D ESCR IP TI ON MOD EL /SI ZE P ART NO . 1 Pr o ce sso r Bo ard CH 17 6- 1 5. 1 2 Tran s former CH 17 6- 1 5. 2 3 El e ct ric al Bo x CH 17 6- 1 5. 3 4 El e ct ric al Bo x Co ve r CH 17 6- 1 5. 4 5 C apa ci tor CH 17 6- 1 5. 5 6 Se tu p Bo ar d CH 17 6- 1 5. 6 6 5 1 3 2[...]
-
Page 29
27 CIRCUIT DIAGRAM M ODE L N O.: CH 7 6 30SQB CH 7 636 SQB MOTOR MOTOR CAPACITOR 10uF/450V CAPACITOR 10uF /450V TRANSFORMER PROCESSO R BOARD CONTROL BOARD HALOGEN LIGH T RED BLACK WHITE YELLOW GREEN BROWN BROWN RED RED GREEN GREEN WHITE WHITE RED BLACK BLACK BLACK WHITE RED 120V 60Hz[...]
-
Page 30
28 M ODE L N O.: CH 7 6 42SQB CH 7 648 SQB 120V 60Hz RED WHITE BLACK BLACK BLACK RED WHITE WHITE GREEN GREEN RED RED BROWN BROWN GREEN YELLOW WHITE BLACK RED HALOGEN LIGHT CONTROL BOARD PROCESSOR BOARD TRANSFORMER CAPACITOR 10uF/450V CAPACITOR 10uF/450V MOTOR MOTOR[...]
-
Page 31
29 DISCLAIMER 1. C A RE FULL Y I N S PECT A L L ITE M S FOR DAMAGES BEFORE A CCE PT IN G DELI V ER Y . NOTE A NY D AMAGES O N T HE FREIGHT BI LL OR EXPRESS RE C E IP T . R EQ U E ST NA ME A ND SIGNA T URE OF T HE CA RR IER’S A GENT A ND KE EP C O PY TO SUPPORT YOUR CLAIM . Upon accepta n ce of items, owner a ssumes resp onsib ility for its safe a[...]
-
Page 32
30 W ARR AN T Y W ARRAN T Y CE RTIFICA T E KOBE Range Hoods, Inc. warra n ts all products m anufa ctured o r supplied by it to b e free from de f ect s in workmanship and materials. Its obligations p ursuant t o this w arranty are limited to a period of two years f rom the d ate of purchase and to the rep a ir o r replacem e nt at it s o ption and [...]
-
Page 33
31 3) The purchaser shall b e responsible fo r any expenses involved in m a king the range hood readily acces si b le fo r servicin g and where t he r a nge h ood is installed outsi d e t he m a in sales t errit o ry of the retailer or service territory of the nearest approv e d KOBE Range Hoods Agent as a p plicable, f or any traveling expenses an[...]
-
Page 34
32 PRODUCT REGISTRA T I O N Regist e r Y our Product! Any covere d f ailure occu rring wi thin two years o f original p u rchase arising f rom d ef ective workmanship o r ma terial in manu fa ctu r e will be re paired or at our option t h e unit will be replaced f r e e of charge by an authorized KOBE Range Hoods Agent or KOBE Ran g e Hoods as appl[...]
-
Page 35
KO BE R an g e Ho od s 10 50 5 V al le y Bl vd Su i te # 3 02 El Mo nt e, C A 9 17 3 1 USA http:// www .K OB ERan geH oods.c om Thi s KOBE ho od i s manu fa ct ur ed for use i n the USA an d C ANAD A on l y . W e do no t r ecomm en d u si ng thi s h oo d ov er sea s a s th e po wer su ppl y may n o t be co mpati bl e and may vi o l a te the el ec t[...]