Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Kohler CFI230J, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kohler CFI230J one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Kohler CFI230J. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Kohler CFI230J should contain:
- informations concerning technical data of Kohler CFI230J
- name of the manufacturer and a year of construction of the Kohler CFI230J item
- rules of operation, control and maintenance of the Kohler CFI230J item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kohler CFI230J alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kohler CFI230J, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kohler service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kohler CFI230J.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Kohler CFI230J item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CFI230J Indigo Quadrant Enclosur e with integrated Mira Magna Shower System (6 46) Fitting + User Instructions 1 2 3 4 1 2 3 4 Slide Rail Fixed Head Kohler Daryl Limited Alfred Road, W allasey , W irral, CH4 4 7HY England T el 44 (0)151 6 06 5 000 Fax 44 (0)151 63 8 0303 www .daryl-showers.co.uk E-mail Daryl@daryl-showers.co.uk[...]

  • Page 2

    [...]

  • Page 3

    26 CF I230J 3 CF I230J Intro duction The following pages aim to provide comprehensive installation instructions, plus advice on how to care and maintain your product. W e recommend that the unit is installed by a qualified Plumber or Engineer . Please retain this document for future reference. Note: Due to our desire to always improve our products,[...]

  • Page 4

    4 CF I230J 25 CF I230J COM P ON E NTS Lintel Standard T op Caps Parking Block Side Panel Door Splashguard Cap Fixed Roller Cap x2 LH RH x2 Nylon Grub Screw Seal Blanking Cap Support the weight of the column. Connect the water pipe to the connector from at the top of the column. Caution Support the weight of the column. Plug the electrical c able in[...]

  • Page 5

    24 CF I230J 5 CF I230J COM P ON E NTS 5mm 3mm Slide Rail W ater Delivery System Roller Securing Caps Splashguard W ater Delivery T op Caps W ater Delivery W all Jamb, W all Channel & Glass Clamp Glass Panel x9 (+4) A x3 C x4 (+1) B x13 3mm 6mm OR Fixed Head W ater Delivery System 2m Pipe and Connector Electrical Cable RH LH Door Stop V inyl (ex[...]

  • Page 6

    6 CF I230J 23 CF I230J Remove wall channel fr om jamb and place against mark on wall Adjust wall jamb until glass is parallel to the edge of the tray ‘ A ’ . W hen jamb is vertical mark edge of wall channel on the wall ‘B’ . STEP 1 E N CL OS U R E I N ST ALLA TI ON Non W ater Delivery Side only Loosely fit wall c hannel into glass panel jam[...]

  • Page 7

    22 CF I230J 7 CF I230J Check the wall c hannel is vertic al and mark through the 3 holes ‘ A ’ A Drill 3 x 6mm holes Fit plugs Loosely fit scr ews A Seal behind channel and tighten screws A B STEP 5 STEP 6 STEP 7 STEP 8 Slide glass panel into slot in tray “ A ’ and fit jamb onto wall channel ‘B’ On the inside of the enclosure. pull the [...]

  • Page 8

    8 21 Check glass is vertical. If not remove scr ews, re-drill and re-fit as r equired. Re-fit rubber strip over screws Drill 4 x 3mm holes through jamb into wall channel STEP 10 STEP 11 Fit 4 x screws B Ensure glass panel is vertical STEP 9 Slacken scr ews ‘ A ’ . Push the glass panel between the wall jamb and the glass clamp. The glass should [...]

  • Page 9

    Drill 4 x 8mm holes Fit plugs Loosely fit 4 x screws A Carefully lift the panel back into postion Seal behind the wall channel and tighten screws A B A Spot drill through 4 fixing holes in the wall jamb and mark the wall. Only 4 of the 8 holes are using alternate sides ‘ A ’ . Carefully r emove the panel from the tray A B Adjust wall jamb until[...]

  • Page 10

    Measure the distance of the glass between the wall jamb and the tray ‘ A ’ . Cut the splashguard to size cutting at the wall jamb end. Fit the splashguard to the bottom of the glass 10 19 CF I230J STEP 19 STEP 20 If the any further adjustment is requir ed to make the glass panel vertical turn the 4 screws ‘D’ until the panel is in the corre[...]

  • Page 11

    18 CF I230J 11 CF I230J Keeping your enclosure beautiful throughout its lifetime is easy with products from the Daryl care programme The Daryl Care Programme Using state of the art bespoke machinery combined with the latest technology, all Daryl doors and panels are coated with a glass protector in highly controlled factory conditions. The protecto[...]

  • Page 12

    12 17 CF I230J CF I230J The unit should be cleaned regularly . Use a non abrasive cleaner (ideally with a pH value of 4 to 8) applied with a soft cloth. Under no circumstances should scourers or power ful detegents be used as these can damage the metallic surf ace of the frame and also tarnish the glass coating. T o avoid limescale, use your thumb [...]

  • Page 13

    16 CF I230J 13 TR OU B LE S H OO TI N G CF I230J The information below gives details on what you can do as a user should you encounter difficulties whilst operating the shower . If there is a problem with the shower control some of the push buttons will flash very fast. Malfunction Cause Remedy Push buttons are flashing on the shower control and / [...]

  • Page 14

    14 CF I230J 15 CF I230J C O MMISSI O NIN G/S ETTI N G 1. General 1.1. T urn on the water supply to the Digital Mixer. 1.2. Check for leaks over the complete system. 1.3. T urn on the electrical supply to the Digital Mixer. For the Pumped V ersion with the Slide Rail System, pump priming can be helped by removing the handset and lowering the end of [...]