Go to page of
Similar user manuals
-
Digital Camera
Kowa nonmyd WX 3D
64 pages 9.88 mb -
Saw
Kowa SL-15
22 pages 2.22 mb -
Microscope & Magnifier
Kowa TSN-773/774
4 pages 0.37 mb -
Camera Lens
Kowa LMVZ3510-IR
1 pages 0.1 mb -
Inflatable Bouncy Toy
Kowa fm600
43 pages 1.22 mb -
Telescope
Kowa RB-525-B04
40 pages 0.38 mb -
Microscope & Magnifier
Kowa TSN-883/884
4 pages 0.37 mb -
Switch
Kowa KE811CT
35 pages 0.65 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Kowa SL-15, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Kowa SL-15 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Kowa SL-15. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Kowa SL-15 should contain:
- informations concerning technical data of Kowa SL-15
- name of the manufacturer and a year of construction of the Kowa SL-15 item
- rules of operation, control and maintenance of the Kowa SL-15 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Kowa SL-15 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Kowa SL-15, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Kowa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Kowa SL-15.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Kowa SL-15 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTRUCTION MANUAL PORTABLE SLIT-LAMP Kowa SL-15[...]
-
Page 2
P - 1 Warning Warning Warning Caution Caution INTR ODUCTION Accept our congratulations on your purchase of Kowa's Portable Slit-lamp. This manual provides a description of the operating procedure of this unit along with important precautions to be observed during its use. Please read this entire manual carefully to assure that the instrument c[...]
-
Page 3
P - 2 WARNING WARNING Obligatory If any abnormal smell or sound, or overheating or smoke should be detected, turn off the instrument immediately and then unplug it. If it should continue in use, a fire may break out on the instrument resulting in its malfunctioning. Contact the Kowa dealer where you purchased it or your nearest repair shop for insp[...]
-
Page 4
P - 3 Caution Caution Prohibitory For unplugging from the outlet, pull the power cord out of it while holding the plug with your hands. Otherwise, there may occur a fire or electrical shock. Do not put in, or pull out of, the outlet, the plug with your wet hands to avoid electrical shock. Do not install the instrument unstable locations, for instan[...]
-
Page 5
P - 4 Operational precautions f or saf ety and accident prev ention in use of batter y Kowa's SL-15 uses a lithium ion battery in its power pack. Always take the following precautions to avoid a serious injury or burn caused by fluid leakage, heat build-up, ignition and explosion as well as occurrence of a fire. If any irregularity or fluid le[...]
-
Page 6
P - 5 Oper a tional pr ecautions ● The instrument should be installed and/or stored in a dust free place free from high temperatures, high humidity and direct sunlight. The environmental conditions described below should be observed strictly . In operation In storage Environmental temperature 10˚C to 40˚C -15˚C to 60˚C Relative humidity 30% t[...]
-
Page 7
P - 6 Operational Considerations for Hospital Grade Electrical Equipment (Saf ety and Accident Prev ention) This section describes general precautions concerning the use of medical electrical instrument based on Notification No. 495 of the Pharmaceutical Affairs Bureau of the Ministry of Health and Welfare dated June 1, 1972. 1. Only qualified pers[...]
-
Page 8
P - 7 Power cable:1 pc. Fuse:2 pc. Lump:1 pc Dust cover:1 pc. Instruction manual:1 pc. Accessories[...]
-
Page 9
P - 8 Contents Introduction ............................................................................................................. 1 Operational Considerations for Safety and Accident Prevention ............................ 1 Precautions in use of battery (safety/accident prevention Operational precautions ...................................[...]
-
Page 10
Name and function of eac h par t 1. P - 9 Main unit (slit-lamp) 1 Prism box For adjusting the eye-to-eye distance, bend and stretch this part both ways. 2 Ocular With rubber attachment for compen- sating the diopter of the laterally bi- ased eye either way . 3 Objective lens An image 10 times as large as a subject can be recorded. An image 16 times[...]
-
Page 11
P - 10 1. Name and function of eac h par t Picture of power source as viewed from above (The figure seen from the top) F Main unit's charger indicating lamp When the power pack inside of the main unit, which is set at the main unit's charger , is being charged, the indicating lamp comes on to emit orange light. When charging is complete, [...]
-
Page 12
P - 11 1. Name and function of each part Battery (power pack) M Battery connector When it is set at the main unit or power pack charger , set the battery connector such that it can be in proper contact with the charger . Option (forehead rest) N Forehead rest Fix the forehead rest such that the examined patient's forehead can rest against it. [...]
-
Page 13
2. Pr epar ation P - 12 IN 1 Open the grip cover 2 Mount the power pack 3 Close the grip cover 2-1 Setting Place the power source on a stable table and connect the power cable to the inlet on the back of the power source. Connecting the power cable 4 Insert the power cable deep into the inlet at the back of power source while holding the main unit [...]
-
Page 14
P - 13 2-3 Charging a single power pack independently of the main unit 2-3 Char ging a single po w er pack independentl y of the main unit 1 Insert the power pack deep into the power pack charger while holding it in the direction of photo. 2 Make sure the power pack charger indicating lamp is on emitting orange light. When charging is complete, lig[...]
-
Page 15
P - 14 2. Prepar ation Caution Caution Caution 2-5 Char ge time and ser vice time of pow er pac k 1 The reference charge time spent in fully charging an exhausted battery at a room temperature of 25˚C is indicated below: Charge time With main unit charger About 90 minutes With power pack charger About 120 minutes Keep in mind that charge time will[...]
-
Page 16
P - 15 3. Ho w to use 2 Adjusting ocular diopter value 3-1 How to hold the slit-lamp 1 Hold the slit-lamp's main body . securely grabbing its grip by your right (or left) hand. 2 Place the other hand's thumb on the side of upper-end of the slit-lamp's main body . 3 Stabilize slit width indication by adjusting the distance between the[...]
-
Page 17
P - 16 3. Ho w to use 3-3 How to use magnifying pow er select le v er , slit-disk and filter-disk. 1 T urn the magnifying power select lever clockwise as indicated by arrow-head to select a magnifying power of 16. T urn it counterclockwise to select a magnifying power of 10. 2 Slit-disk T urn the slit-disk as far as it is set at one of the four cli[...]
-
Page 18
P - 17 4. T r oubleshooting This section describes how to take action against any irregularity which occurred on the instrument. If any irregularity should occur on the instrument, check if the following faults are observed, before contacting Kowa's dealer where you purchased the instrument for repair . Be sure to turn off the power source bef[...]
-
Page 19
P - 18 5. Maintenance and inspection Caution Caution Caution 5-1 Dail y inspection 1 If you do not operate the instrument any longer for the day , be sure to turn off the power switch and put a cover on it. 2 Care must be used to keep the objective lens free from dust and dirt, fingerprints, tear-drops and so forth. 3 Clean fouled main unit, power [...]
-
Page 20
P - 19 Caution Caution 5-3 Replacing fuse 5-3 R eplacing fuse 1 With the power switch turned off, unplug the power cable from the outlet. 2 Unscrew the power source's fuse holder cover by turning minus (-) screw driver counterclockwise to take out the fuse from within. 3 Make sure a new fuse to be used, is a designated capacity and type. Then [...]
-
Page 21
P - 20 6. Specifica tions Main unit (slit-lamp) [Microscope] Type : Binocular-stereoscopic-orthoscopic microscope Inward angle : 13 ˚ Magnifying power : 10/16 Objective lens' working distance : About 80 mm (when a magnifying power of 16 is selected) About 100 mm (when a magnifying power of 10 is selected) Practical field of view : Ø 10 mm (w[...]
-
Page 22
Printed in Japan SL 150 V1.1 E 030701 MS Printed on recycled paper. 20001 So. Vermont Ave. Torrance, CA 90502, U.S.A. Phone: 1(310) 327-1913 Facsimile : 1(310) 327-4177 Immermannstrasse 65A 40210 Düsseldorf F.R. Germany Phone: 49(211) 35-3444/45/46 Facsimile: 49(211) 161952 Life Science Division No. 4-14, 3-chome, Nihonbashi-Honcho, Chuo-ku, Tokyo[...]