A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth Products Elite CVF-LP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth Products Elite CVF-LP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth Products Elite CVF-LP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth Products Elite CVF-LP should contain:
- informations concerning technical data of Lennox Hearth Products Elite CVF-LP
- name of the manufacturer and a year of construction of the Lennox Hearth Products Elite CVF-LP item
- rules of operation, control and maintenance of the Lennox Hearth Products Elite CVF-LP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth Products Elite CVF-LP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth Products Elite CVF-LP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth Products Elite CVF-LP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth Products Elite CVF-LP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Report No. 317-F-09-5 IN ST AL LA TI ON AN D OP ER A TIO N MA NU AL Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not light any appliance. • Do not touch any electrical switches; do not use any phone in your building. • Immediately call your[...]

  • Page 2

    2 • Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. • Y oung children should be carefully super vised when they are in the same room with the heater . • Do not place clothing or other flammable material on or near the heater . • Any safety screen or g[...]

  • Page 3

    3 2.0 GENERAL INFORMA TION This appliance is a high efficiency , unvented, flame effect gas heater . It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology . The appliance does not require a flue system of any type as the catalytic converter cleans the flue products [...]

  • Page 4

    6.0 BURN-IN PERIOD 4 On initial light up of a new appliance, the ‘newness’ will burn off within the first few hours of operation. During this period some smoke may be emitted from outlet grill, this should be no cause for concern. Accord- ingly , the room should be well ventilated with all windows and doors open during this period. Depending o[...]

  • Page 5

    5 8.0 COMBUSTION AND VENTILA TION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventil ation air . The heater may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openi[...]

  • Page 6

    9.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bedrooms or bathrooms - or areas where large amounts of steam are likely to be generated. It should be noted that heaters create warm air currents. These currents move [...]

  • Page 7

    Figure 1 - Gas Supply Entr y Points 10.0 PREP ARING THE APPLIANCE IMPORT ANT NOTE: All gas piping must be done by a licensed plumber or gas fitter and must conform to the requirements of the National Fuel Gas Code NFP A 54 / ANSI Z223.1 - latest edition Gas connection: The heater gas inlet connection is 3/8” NPT at the regulator , located below [...]

  • Page 8

    Figure 3 11.0 MOUNTING THE APPLIANCE - continued Before tightening the wall-mounting screws fully , at this stage it is recommended to check the horizontal alignment of the appliance with a spirit level, as small adjustments can still be made if necessar y . When this has been checked, tighten all four fixing screws fully . T o access the upper fix[...]

  • Page 9

    Retaining clip Burner (Manifold) Pressure Regulator Pressure Setting T urn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution). NOTE: using a soapy water solution (50% dish soap, 50% water) is an effective leak test solution, but it is not recommended, because the soap residue that is left [...]

  • Page 10

    Figure 10 Figure 11 Figure 12 16.0 SP ARK GAP The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark. There should be no need to adjust this (DO NOT A TTEMPT TO ADJUST THE GAP). If under any cir cumstances the piezo electric spark fails, the pilot cannot be lit manually . 17.0 FITTING THE DECORA TIVE G[...]

  • Page 11

    11 19.0 SERVICING (continued) 3. Remove the glass door assembly (4 screws) and clean carefully . Detach the burner front cover plate by removal of the four retaining screws. 4. Inspect the burner and the catalysts and clean if necessar y with a soft brush. 5. Disconnect the gas supply . IMPORT ANT NOTE: This must be done by a licensed plumber or ga[...]

  • Page 12

    23.0 TESTING FOR FIREBOX LEAKAGE Appliances that are several years old or have been extensively dismantled should be checked for soundness. It is important that all the products of combustion pass through the catalytic convertors at the top of the firebox before leaving the appliance. The firebox is heated by lighting for a few minutes to provide[...]

  • Page 13

    13 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo spark igni ter . When lighting the pilot, follow these instructions exactly . B. BEFORE OPERATING [...]

  • Page 14

    14 26.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly . • Blocked pilot, clean out internally . Pilot lights but then goes out • Severe rest[...]

  • Page 15

    15 27.0 REPLACEMENT P ARTS - Elite CVF - NG and Elite CVF - LP Item # Cat. No. Description 1 H7009 Glass Door Assembly 2 H6060 Catalyst 3 H6061 Pilot Assembly , Natural Gas 4 H6999 Pilot Assembly , Propane Gas 5 H7010 Burner Assembly , Natural Gas 6 H7011 Burner Assembly , Propane Gas 7 H6062 Catalyst Gasket 8 H7007 Decorative Glass Facia 9a H7002 [...]

  • Page 16

    16 Figure 16 - Visual check for correct pilot flame. W ARNING Fai lur e to pos itio n the part s in acc ord ance with thes e dia gra ms or fai lure to us e only pa rts sp ecifi call y app rov ed with this hea ter may resul t in prop ert y dam age or pers ona l in jury . NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 28.0 POSITIONING OF FIELD[...]

  • Page 17

    17 29.0 SPECIFICA TIONS 6-1/4” 23-7/8” 27-3/16” 9-3/16” 20-1/4” B ac k Vi e w T o p V i ew F ro n t V i ew P r od u c t R e f e r en c e In f o r m at i o n Cat. No. Model S hi p . W t . Ship. Volume H 60 7 2 E li t e C V F - NG 5 0 l b . 4 .3 c u. ft . H 60 7 3 E li t e C V F - LP 5 0 l b . 4 .3 c u. f t.[...]

  • Page 18

    Printed in U.S.A. © 2008 Lennox Hearth Products P/N 850,056M Rev . A 11/2008 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. WARRANTY Y our gas app[...]