Go to page of
Similar user manuals
-
Log Splitter
Lennox Hearth LSVFSD-NG
20 pages 1.75 mb -
Log Splitter
Lennox Hearth LSVFSD-24
4 pages 0.74 mb -
Log Splitter
Lennox Hearth LSVFSD-30
4 pages 0.74 mb -
Log Splitter
Lennox Hearth LSVFSD-8
4 pages 0.74 mb -
Log Splitter
Lennox Hearth LSVFSD-24
20 pages 1.75 mb -
Log Splitter
Lennox Hearth LSVFSD-30
20 pages 1.75 mb -
Log Splitter
Lennox Hearth LSVFSD-18
20 pages 1.75 mb -
Log Splitter
Lennox Hearth LSVFSD-LP
20 pages 1.75 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth LSVFSD-LP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth LSVFSD-LP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth LSVFSD-LP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Lennox Hearth LSVFSD-LP should contain:
- informations concerning technical data of Lennox Hearth LSVFSD-LP
- name of the manufacturer and a year of construction of the Lennox Hearth LSVFSD-LP item
- rules of operation, control and maintenance of the Lennox Hearth LSVFSD-LP item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth LSVFSD-LP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth LSVFSD-LP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth LSVFSD-LP.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth LSVFSD-LP item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Report No.116-L-49-5 I N S T A L L A T I O N A N D O P E R A T I O N I N S T R U C T I O N S V ent-Free Millivolt Dual-Listed Gas Log Sets Shadowdance™ Series P/N 85005 1M R ev . C , 03/2 01 1 I n the Commonwealth of Massachusetts: • I ns tal lat ion mu st be pe rfo rm ed by a l ice ns ed plu mbe r or gas t ter • See T able of Contents for[...]
-
Page 2
2 IM PO R T A NT S AFE TY A ND W AR NI NG IN FO RM A T IO N REA D TH IS M ANUA L IN ITS ENTI RETY AND UNDE R- ST AN D TH ESE RULES TO FOLL OW F OR SA FETY . W ARNINGS If th e i nfo rma tio n i n t his ma nua l i s n ot fol - lo wed ex act ly , a fi re or exp losi on may re sul t ca usi ng pro per ty dam age , p ers ona l i nju r y or lo ss of lif [...]
-
Page 3
3 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. These Gas Log Appliances incorporate unitized ceramic fiber logs which provides some glow realistically when the appliance is operating. The gas log sets covered in this document are heater rated units. These units are equipped with a millivolt gas valve. The control knob is set to the desired [...]
-
Page 4
4 Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223.1 or NFPA 54-latest edition which can be obtained from The American National Standards Institute, Inc. (1430 Broadway , New Y ork, NY , 10018) or National Fire Protection Association, Inc. (Batterymarch Park, Quincy , MA, 02269). State or loca[...]
-
Page 5
5 This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and venti lation air. The heate r may be located in unusua lly tight construc - tion provided the space is unconfined, or if confined, is provided with two permanent openings communicating directly with [...]
-
Page 6
6 Not e: Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for reference only . Actual installations may vary due to individual design preferences. However , always main- tain minimum clearances to combustible materials and do not violate any specific installation requirements. Refer to Figures[...]
-
Page 7
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 7 Figure 3 Step 2. Ceiling Clearance: The ceiling must be at least 42" from the top of the appliance opening ( Figure 2 ) . Step 3. Noncombus tible materials (minimum requiremen ts): T o install the appl iance wi thout woo d mantel s, shelv es or other comb ustib le projec - tions directly ab[...]
-
Page 8
8 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. Any outside air ducts and/or ash dumps in the fireplace shall be perma- nently closed at time of appliance installation. A qualified gas appliance installer must install this dual-listed appli - ance. Check gas type: The gas supply must be the same as stated on the applia nce’ s rating plate[...]
-
Page 9
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 9 The appliance gas inlet connection is 3/8" NPT at the regulator/valve, located on the left side facing the appliance. If a right side connection is requ ired, the conn ection pip e may be pipe d under the rear of the appli ance to end at the left hand side for connection to the inlet. When [...]
-
Page 10
10 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. LOG PLACEMENT INSTRUCTIONS 1. Place rear ember bed as shown in Figure 11 . Figure 11 - Install Rear Ember Bed 2. Place rear log onto the two rear grate locating pins as shown in Figure 12 (the locating pins are outlined in Figure 11 ). 3. Place middle log onto left middle grate locating pin and[...]
-
Page 11
11 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 7. Place the right top log onto rear log locating pin and the right front log locating pin as shown in Figure 17 . Right T op Log Locating Pins 8. Pla ce Lef t T op T wig (24 " and 30" mod els only ) ont o cor resp ondin g notch on rear log as shown in Figure 18A . The front of the Le[...]
-
Page 12
12 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. T op Burner Air Shutter Adjustment Procedure 1. If you ha ve blue flame or the top bur ner is no t carry ing ove r and bu rning on all ports , the air shutter may need to be adjusted to 1/8 " gap for bot h Natu ral a nd Pro pane gas. 2. Check to see if the air shutte r is set to 1/8"[...]
-
Page 13
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 13 1. Appliance operation may be controlled through the ON/OFF unit rocker switch, located in the bottom front of the appliance or through an optional remote control . 2. When lit for the first time, the appliance will emit an odor for an hour or two. This is due to the “burn-in” of the inter[...]
-
Page 14
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 14 (ref form #750127M) (ref form #750129M) Standard Remote Control System (Model RCL) The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter , a remote receiver with wall-mount cover plate and al[...]
-
Page 15
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 15 (ref form #750252M) (ref form #750010M) ACCESSORY COMPONENTS (CONTINUED) * Fo r use with g as tra in mode ls LSV FSD-NG and L SVFSD-L P only 18" Gas Log Set 24" Gas Log Set Charred Ember Kit* Cat. No. Model No. Description H689 4 LSVFS D-CEK Char red Em ber Ki t Charred Ember Kit An o[...]
-
Page 16
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 16 * For the purpose of input adjustment. PILOT (O.D.S.) ASSEMBLY THERMOPILE WHITE WHITE WHITE RED MILLIVOL T VAL VE ON/OFF SWITCH PILOT PIEZO IGNITER IGNITION WIRE OFF ON OPTIONAL REMOTE CONTROL (MILLIVOL T) Vented/Unvented Gas Log Appliance T echnical Chart For Millivolt Log Set Model No. BTU/HR[...]
-
Page 17
17 4. Depress gas control knob slightly and turn clockwise to “OFF .” Do not for ce. 5. Close lower control compartment. LIGHTING INSTRUCTIONS – MILLIVOL T WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING[...]
-
Page 18
18 VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is pressed, there is no spark at ODS/pilot. A. Igniter electrode positioned wrong. Replace igniter . B. Igniter electrode broken. Replace igniter . C. Igniter electrode not connected to igniter cable. Reconnect igniter cable. D. Igniter cable pinc[...]
-
Page 19
19 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS LIST (MILLIVOL T) - SHADOWDANCE™ SERIES Replacement Parts List (Millivolt) - Shadowdance™ Series, Models LSVFSD-NG and LSVFSD-LP (18" and 24") No. Description Catalog Number 1. Valve, Millivolt (Natural) H1203 Valve, Millivolt (Propane, L.P .G.) H4278 2. Ember B[...]
-
Page 20
20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N 850051M REV . C 03/2011 1508 Elm Hill Pik[...]