Lennox Hearth RDV40 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth RDV40, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth RDV40 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth RDV40. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth RDV40 should contain:
- informations concerning technical data of Lennox Hearth RDV40
- name of the manufacturer and a year of construction of the Lennox Hearth RDV40 item
- rules of operation, control and maintenance of the Lennox Hearth RDV40 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth RDV40 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth RDV40, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth RDV40.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth RDV40 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Report No. 050-S-15c-5 INST ALLA TION AND OPERA TION MANUAL Direct-V ent Gas Fireplace Inserts Retain These Instructions For Future Reference W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result. • Carefully[...]

  • Page 2

    2 T able of Contents C autions & s afety ..................................................................................... 3 o rifiCe s ize / a l titude a djustment .................................................................... 4 f ireplaCe r equirements ................................................................................ [...]

  • Page 3

    3 C autions & s afety  FOR YOUR SAFETY do not install or operate your Ravenna™ gas insert without first reading & under - standing this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty & may be hazardous.  INST ALLA TION & REP AIR SHOULD ONL [...]

  • Page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for every 1,000 feet to maintain the proper ratio of gas to air . Improper orifice sizing may result in damage and unsafe conditions. Chang - ing the orifice sho[...]

  • Page 5

    5 Inspection The state or local gas inspector of the side wall horizontally vented gas fuel ed equi pme nt shal l not app rove the insta lla tion unless, upon ins pect ion, the inspector obser ves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions Th e fo ll ow in g eq ui p[...]

  • Page 6

    6 Pre-Installation f ea tures Installation Options Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The standard fan motor requires 120 Volts AC for operation. The fireplace is not dependent on the fan or an outside elec - trical supply to operate. WARNING - Electrical Grounding [...]

  • Page 7

    7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. i nsert d imensions m inimum f ireplaCe o pening r equired A = 29-3/4” (756mm) Front Opening B = 19-1/2” (495mm) Height C = 19” (483mm) Rear Width D = 16” (406mm) Fireplace Depth * T op air duct will need to be removed for short ZC applica - tions. Replace tap tights when removed. m in[...]

  • Page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Facing & Mantel - Side View rdv33 f aCing and m antel C learanCes (rdv40 - add 4" to rdv33 dimensions ) Note: Hearth protection to be min. 3/8” (10mm) thick non- combustible or equivalent, with a k factor of .84. i nsert l eveling At each front and rear corner of the insert is an ad[...]

  • Page 9

    9 v ertiCal v enting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate. The combustion air vent pipe can be connected to the termination cap or it can terminate inside the chimney . The bottom opening of the chimney must be sealed around[...]

  • Page 10

    10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. z ero C learanCe f ireplaCe i nst allation This insert may be installed in a masonr y or factor y built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open. The ZC doors, screen, refractor y or maso[...]

  • Page 11

    11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4. Install a light layer of rockwool directly over the ports. - A light layer will give a more constant rear flame. - A heavy layer will give more glow , but will need to be adjusted after light up. 5. Install front logs on retainer slots. f aCe i nst allation A number of different face fin[...]

  • Page 12

    12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Line Installation After leveling, position the insert in the fireplace - holding it about six inches out from its final location. Caution: Specific hearth requirements apply (see Clear - ances to Combustibles). The Ravenna™ gas insert must be connected to the gas line in accordance w[...]

  • Page 13

    13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Instructions p re -l ighting C heCklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas. c Gas pressure h[...]

  • Page 14

    14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit. 6. T urn the gas control knob counter -clockwise to the "PILOT" position. 7. Push the knob all the way in and hold in that position. Immediately light the pilot by pr[...]

  • Page 15

    15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Paint Curing This insert has been painted with StoveBright high tem- perature metallic stove paint. It leaves the factor y dry to the touch, but finishes curing as the insert is used. Fire the insert four successive times for ten minutes each time with a five minute cool down between each ?[...]

  • Page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. o pera ting o ptions The rocker switch on your Ravenna™ gas insert is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole in the right side of the top surround panel or in the hole in the panel to the left of the igniter button. The hole [...]

  • Page 17

    17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintenance & Ser vicing m aintenanCe C heCklist The following should only be performed by a qualified service technician. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after serv[...]

  • Page 18

    18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fan Snap Switch Fan Speed Control White Ground (Green) Black Blower Black (Hot) White (Neutral) Power Source Blower Wiring Schematic g lass d oor r emov al Caution: Do not slam or strike glass door or damage may occur . Do not remove the glass door while the insert is hot. T o re - move the g[...]

  • Page 19

    19 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Brick Panel and Log Set Installation on Pages 10 & 11 . If there is soot in one specific location, the rockwool below this location need[...]

  • Page 20

    20 Replacement Parts Ravenna™ 33/40 (RDV33/40) Part Number Description 47500 Cassette Assembly NG 33,000 BTU (if LP , also requires H5433 Conversion Kit) H3045 Cassette Assembly NG 40,000 BTU (if LP , also requires H5433 Conversion Kit) H6010 Burner Assembly H5922 Pilot Assembly Convertible, NG or LP H5938 Gas Control Valve NG (if LP , also requi[...]

  • Page 21

    21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES RDV40 RDV33 E = T op Facing to Bottom of Insert 35.5”(902mm) 31.5”(800mm) F = Cent er of G las s to Si de F aci ng o r S id e W al l 25.5”(648mm) 25.5” (648mm) *J = 10.5” (26 7m m) Mantel to Bottom of Insert 43”(1092mm) 39”(991mm) * See owner?[...]

  • Page 22

    22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUT ION : YOU R CO UNT R Y G AS APPLIA NCE MUS T AL WA YS B E O PER A TE D W ITH GLA SS DOO R IN PL ACE . STO P! Rea d t he s afe ty info rma tio n a bove be for e pr oce edi ng. 1. Ope n t he l owe r d oor . Ma ke sur e g as s upp ly shut -of f c ock s ar e o pen an d ON /OF F Rock er Swi t[...]

  • Page 23

    23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. WARRANTY Y our gas appliance is covered by a limited warranty (provided with appliance). Please read the warranty to be familiar with its coverage. Retain this manual. File it with your other documents for future refer - ence. PRODUCT REFERENCE INFORMA TION We recommend that you record the fo[...]

  • Page 24

    Printed in U.S.A. © Lennox Hearth Products 2007 P/N 775,218M REV . A 05/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. 1110 West T aft Avenue • Orange, [...]