Go to page of
Similar user manuals
-
Switch
LevelOne GSW-1674T
41 pages 0.56 mb -
Switch
LevelOne FSW-0800FXT
14 pages 1.75 mb -
Switch
LevelOne GSW-2692
390 pages 4.82 mb -
Switch
LevelOne GSW-2453
16 pages 0.29 mb -
Switch
LevelOne GSW-0440T
21 pages 0.42 mb -
Switch
LevelOne GSW-2690
265 pages 6.96 mb -
Switch
LevelOne KVM-0407
19 pages 0.2 mb -
Switch
LevelOne FSW-2421
10 pages 0.41 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of LevelOne IFE-0502, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of LevelOne IFE-0502 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of LevelOne IFE-0502. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of LevelOne IFE-0502 should contain:
- informations concerning technical data of LevelOne IFE-0502
- name of the manufacturer and a year of construction of the LevelOne IFE-0502 item
- rules of operation, control and maintenance of the LevelOne IFE-0502 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of LevelOne IFE-0502 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of LevelOne IFE-0502, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the LevelOne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of LevelOne IFE-0502.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the LevelOne IFE-0502 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
LevelOne IFE-0501/IFE-0502 4-Port PoE + 1-Port SC Industrial Fast Ethernet Switch User Manual V er . 1.0.0-071 1 1[...]
-
Page 2
FCC W arning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of t he FCC rules. These limits are designed to provide reasonable protection against harmful in terference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy . It may c[...]
-
Page 3
Content INTRODUCTION ...................................................................................... 4 F EA TURES ................................................................................................................. 4 P ACKAGE C ONTENTS ..............................................................................................[...]
-
Page 4
Introduction The 4-Port PoE + 1-Port SC I ndustrial Fast Ethernet Switch is a cost-effective solution and meets the high reliability requirement s demanded by industrial applications. Using fiber port can extend the connection distance t hat increases the network elasticity and performance. In addition, the industrial switch provides the PoE functi[...]
-
Page 5
Package Content s Please refer to the package content s list below to verify them against the checklist. IFE-0501(or IFE-0502) CD Manual Pluggable T erminal Block (att ached on the switch) 2 wall mount plates with screws One DIN-Rail (attached on the switch) Compare the content s of the i ndustrial switch with the standar d chec[...]
-
Page 6
Hardware Description In this paragraph, the Industrial switch’ s hardware spec, port, cabling information, and wiring installation will be described. Physical Dimension 4-Port PoE + 1-Port SC Industrial Fast Et hernet Switch dimension (W x D x H) is 30mm x 95mm x 140mm Front Panel The Front Panel of the 4-Port PoE + 1-Port Multi-mode SC Indust ri[...]
-
Page 7
The Front Panel of the 4-Port PoE + 1-Port Single-mode SC Indus trial Fast Ethernet Switch is shown as below: Front Panel of the IFE-0502 Indus trial Fast Ethernet Switch T op V iew The top view of the 4-Port PoE + 1-Port SC Industrial Fast Et hernet Switch has one terminal block connector of two DC power inputs. T op V iew of the IFE-0501/IFE-0502[...]
-
Page 8
LED Indicators The diagnostic LEDs located on the front pa nel of the industrial switch provide real-time information of system and optional status. The following t able provides the description of the LED status and their meanings for the switch. LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input[...]
-
Page 9
Port s RJ-45 ports The UTP (RJ-45) Fast Ether net port s will auto-sense for 10Base-T or 100Base-TX connections. Auto MDI/MDIX me ans that the switch can connect to another switch or workstation without changing straight thr ough or crossover cabling. See the below figures for straight through and crossover cable schematic. RJ-45 Pin Assign[...]
-
Page 10
S traight Through Cable Schematic Cross Over Cable Schematic Fiber Port The fiber port of SC type connector can wo rk in multi-mode (2Km) or single-mode (30Km). When you connect the fiber port to another one, pleas e follow the figure below to connect accordingly . Wrong conne ction will cause the port cannot work normally . A TTE NTION This is[...]
-
Page 11
Cabling T wisted-pair segment c an be connected with unshielded twisted p air (UTP) or shielded twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX st andard for Category 5. The cable between the converter and the link partner (switch, hub, workst ation, et c.) must be less than 100 meters (328 f t.) long. Fiber [...]
-
Page 12
Wiring the Power Input s Please follow the steps below to insert the power wire. Insert the positive and negative wires into t he V+ and V - contacts on the terminal block connector . T ighten the wire-clamp scr ews for preventing the wires from loosing. 12[...]
-
Page 13
Wiring the Fault Alarm Cont act The fault alarm contact is in the middle of terminal block connector as the picture shows below . When the wires are inserted in to ports 3 and 4, t hey automatically detect the fault status in the event of a power failure by forming an open circuit. An example for the fault ala rm contact is shown as below: Insert t[...]
-
Page 14
Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the i ndustrial switch when out of factory . If the DIN-Rail is not screwed on the industrial switch, please see the following pictures to screw the DIN-Rail on the switch. Follow the step s below to hang the industrial switch. 1. Use the screws to screw the DIN-Rail on the rear sid[...]
-
Page 15
4. Then, lightly push the DI N-Rail into the track. 5. Check if the DIN-Rail is tightened on the track or not. 6. T o remove the industrial switch from the track, reverse steps above. 15[...]
-
Page 16
W all Mount Plate Mounting 1. Follow the steps below to mount the industrial switch wit h wall mount plate. 2. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 3. Place the wall mount plate on the rear panel of the industrial switch. 4. Use the screws to screw the wall mount plate on the industrial switch. 5.[...]
-
Page 17
Hardware Installation In this paragraph, we are going to mention how to install the 4-Port PoE + 1-Port SC Industrial Fast Ethernet Switch and the installation point s to be attended to it. Inst allation Step s 1. Unpack the Industrial switch p acking. 2. Check if the DIN-Rail is screwed on the Industrial switch or not. If the DIN-Rail is not screw[...]
-
Page 18
Network Application This segment provides the sample to help user have more actual idea of industrial switch application. For a sample applicati on of the industrial s witch, see the figure below . 18[...]
-
Page 19
Troubleshooting V erify that is using the right power cord/adapter (DC 48V), please don’t use the power adapter with DC output voltage hi gher than 48V , or it will burn this equipment down. Select the proper UTP/STP cable to constr uct your network. Please check that is using the right cable. Use unshielded twiste d-pair (UTP) or shield [...]
-
Page 20
Technical Specification The IFE-0501/IFE-0502 4-Port PoE + 1-Port SC Industrial Fast Ethernet Switch technical specifications are shown as below . IFE-0501 4-Port PoE + 1-Port Multi-mode SC Industrial Fast Ethernet Switch IFE-0502 4-Port PoE + 1-Port Single-mode SC Industrial Fast Ethernet Switch Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 10[...]
-
Page 21
Optical cable Dist ance: Multi mode: 50/125 μ m ~ 62.5/125 μ m Single mode: 9/125 μ m A vailable distance: 2km (mul ti-mode)/30km (single-mode) W avelength: 1310nm (Multi-mode/Single-mode) Power Suppl y Redundant power DC 48V with removable terminal block 12VDC (without PoE); 48VDC (Full load with PoE) Power Consumption 4.6W att s (without PoE);[...]