Go to page of
Similar user manuals
-
Air conditioner
LG ARNU07GL1G4
11 pages 0.71 mb -
Air conditioner
LG Art Cool DeLuxe
23 pages 2.3 mb -
Air conditioner
LG A12VK
23 pages 2.76 mb -
Air conditioner
LG ARNU18 GVJA2
13 pages 0.99 mb -
Air Conditioner
LG LAN091CNP, LAU091CNP, LAN121CNP
76 pages 13.72 mb -
Air conditioner
LG A4UW306FA0
147 pages 24.67 mb -
Air conditioner
LG AMNH24GD5L0
27 pages 3.94 mb -
Air conditioner
LG DC09RQ
38 pages 0.78 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of LG L1004R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of LG L1004R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of LG L1004R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of LG L1004R should contain:
- informations concerning technical data of LG L1004R
- name of the manufacturer and a year of construction of the LG L1004R item
- rules of operation, control and maintenance of the LG L1004R item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of LG L1004R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of LG L1004R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the LG service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of LG L1004R.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the LG L1004R item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
LG Window-Type Air Conditioner OWNER'S MANUAL LG website http://www.lgservice.com MODELS, MODELOS: WK Series: LW7000ER LW8000ER WL Series: L1004R LW1000ER L1204R LW1200ER L1404R LB1000ER LB1200ER WP Series: LW1400ER L1504R LW1500ER L1804R LW1800ER ESPAÑOL ENGLISH IMPORTANT Please read through this manual. It contains valuable information abou[...]
-
Page 2
2 Window-T ype Air Conditioner Owner’ s Manual T ABLE OF CONTENTS FOR Y OUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased ■ Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues. READ [...]
-
Page 3
3 ENGLISH Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING CAUTION This symbol indicates the possibility of d[...]
-
Page 4
4 ■ Operation Plug in the power plug properly. • Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not operate or stop the unit by inserting or pulling out the power plug. • It will cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord. • It will cause [...]
-
Page 5
5 ENGLISH Do not allow water to run into electric parts. • It will cause failure of machine or electric shock. Leave the door closed while the air conditioner is running. • It is not designed to cool the entire house. Ventilate before operating air conditioner when gas goes out. • It may cause explosion, fire, and burn. Never touch the metal [...]
-
Page 6
6 Do not place heavy object on the power cord and take care so that the cord should not be pressed. • There is danger of fire or electric shock. If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power-plug out from the socket. Do not clean the air conditioner with wat[...]
-
Page 7
Prior to Operation Safety Precautions 7 ENGLISH Preparing f or operation Contact an installation specialist for installation. Plug in the power plug properly. Do not share the same outlet with other appliances Do not use an extension cord. Do not start/stop operation by plugging/unplugging the power cord. If cord/plug is damaged, replace only with [...]
-
Page 8
TIMER MODE AIR PURIFIER TEMP PO WER FA N SPEED COOL INDOOR DESIRED ENERGY SA VER AIR PURIFIER CLEAN FIL TER FA N FA N DR Y 1 2 7 3 4 5 6 Air Purifier Pow e r Te m p Sleep Mode Timer Auto Swing Fan Speed AIR PURIFIER 1 7 8 2 4 3 5 ˚F TEMP F1 LO W F2 MED F3 HIGH Dry Timer Fan Energy Saver Cool 2 6 Pow e r T emp F an Speed Timer Mode 1 2 3 4 5 1 3 4 [...]
-
Page 9
ENGLISH 9 Push out the cover on the back of the remote control with your thumb Pay attention to polarity and insert two new AAA 1.5V batteries. Reattach the cover. : Do not use rechargeable batteries. Make sure that both batteries are new. • In order to prevent discharge, remove the batteries from the remote control if the air conditioner is not [...]
-
Page 10
10 VENT CLOSE OPEN Part A Adjusting the Air Flo w Direction Operating Instructions V ent Contr ol For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. O P E Nt h ev e n tt od i s c h a r g es t a l ea i r . Adjusting the Air Flow Direction • Recommended orientation of louvers Adjust louvers to face upwards whe[...]
-
Page 11
Drain pipe Drain cap Care and Maintenance Care and Maintenance 11 ENGLISH Turn the power off and unplug the power plug before cleaning the air conditioner. Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remov[...]
-
Page 12
CABINET DRAIN PAN DRAIN HOSE SCREW 12 After removing the Air Purifying Filter, pull slightly forward to remove the Air Purifying filter. Soak the Air Purifying Filter in water mixed with a mild detergent for 20~30 minutes. Dry the Air Purifying Filter in the shade for a day.(The moisture must be removed completely on this part.) Note the cuts of el[...]
-
Page 13
ENGLISH 4 6 5 8 1 2 3 13 11 14 12 10 7 17 16 B A Power cord Power cord 9 15 13 Har d ware Installation Har dware Installation Pr oduct Features 1. CABINET 2. FRONT GRILLE 3. AIR FILTER 4. AIR INTAKE (INLET GRILLE) 5. AIR DISCHARGE 6. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) 7. EVAPORATOR 8. HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) 9. CONTROL PA[...]
-
Page 14
14 About 1 / 2 " 30"~60" Awning Cooled air Fence Over 20" Heat radiation 25" to 36" Offset 1 / 2 " to 1 1 / 4 " Sill Exterior Interior wall 20 1 / 12 " min. (Without frame cur tain) Stool 15" min (With frame cur tain) How to Install the Unit To prevent vibration and noise, make sure the unit is inst[...]
-
Page 15
15 ENGLISH About 1 / 2 " 30"~60" Awning Cooled air Fence Over 20" Heat radiation 27" to 39" Offset 1 / 2 " to 1 1 / 4 " Sill Exterior Interior wall 23 5 / 8 " min. (Without frame cur tain) Stool 16" min (With frame cur tain) How to Install the Unit To prevent vibration and noise, make sure the unit [...]
-
Page 16
16 About 1 / 2 " 30"~60" Awning Cooled air Fence Over 20" Heat radiation 29" to 41" 18" min. Inner sill Offset Window Sash Sill Exterior Interior wall 29" min. (Without frame cur tain) How to Install the Unit To prevent vibration and noise, make sure the unit is installed securely and firmly. Install the unit[...]
-
Page 17
ENGLISH 1 2 3 4 8 13 10 7 6 5 9 12 11 10 13 Shipping Screws (Type A) Upper guide Upper guide (Type A) 5 11 11 5 5 Upper guide 17 Installation Kits Contents Suggested T ool Requirements NO. NAME OF PARTS Q'TY 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3B O L T 2 4N U T 2 5 SCREW (TYPE A) 16 6 SCREW (TYPE B) 3 7 SCREW (TYPE C) 5 8F O A M - S T R I P 1 9[...]
-
Page 18
18 INDOOR OUTDOOR Sill Support 2 Nut 4 Bolt 3 INDOOR OUTDOOR Cabinet About 1 / 2 " Frame Guide 11 Screw(Type A) 5 Upper Guide Window stool Front Angle Window Sash Upper guide Frame Curtain 1 Foam-pe 10 Foam-pe 13 Cabinet Fig. 1 Fig. 2 Fig. 3 Fig. 4 Cabinet Installation Open the window. Mark a line on center of the window stool. Carefully place[...]
-
Page 19
19 ENGLISH Sash track Front Angle About 1 / 2 " Screw(Type B) 6 Screw(Type B) 6 Sill Support 2 Sill Support 2 Foam-Strip 8 Fig. 5 Type C 7 Fig. 6 Screw(Type A) Screw (Type A) Power cord Fig. 7 Fig. 8 The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside (See Fig. 5). Adjust the bolt and the nut o[...]
-
Page 20
20 Window locking bracket 12 Fig. 9 Fig. 10 Fig. 11 Attach the Window Locking Bracket w i t haT y p e C screw .( S e eF i g .9 ) Attach the front grille to the cabinet by inserting the t a b so nt h eg r i l l ei n t ot h et a b so nt h ef r o n to ft h e cabinet. Push the grille in until it snaps into place. (See Fig. 10) Pull down the inlet grill[...]
-
Page 21
21 ENGLISH 11 14 Shipping Screws D E F R O S T H E A T C O O L I N D O O R D E S I R E D E N E R G Y S A V E R A I R P U R Y F I E R A U T O R E S T A R T F A N F A N D R Y D E F R O S T H E A T C O O L I N D O O R D E S I R E D E N E R G Y S A V E R A I R P U R Y F I E R A U T O R E S T A R T F A N F A N D R Y (Type A) 5 (Type A) 1 2 3 4 5 6 7 8 9[...]
-
Page 22
22 3 9 2 6 3 14 11 2 4 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Support Bracket Lock nut Sill Bracket Carriage Bolt Front angle W indow stool Window sash Upper Guide Cabinet Foam -Seal Frame curtain Foam-PE (Type B) Cabinet Track hole Support Bracket Carriage bolt and lock nut Machine screw(Type D) and lock nut Outer edge of window sill Sill bracket Upper G[...]
-
Page 23
23 ENGLISH (Type C) 6 7 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Screw Screw D E F R O S T H E A T C O O L I N D O O R D E S I R E D E N E R G Y S A V E R A I R P U R Y F I E R A U T O R E S T A R T F A N F A N D R Y Screw(Type B) Front Angle Sash track Window loc king brac ket F oam-Strip P ower Cord Pull each Frame curtain fully to each window sas[...]
-
Page 24
24 Fig. 21 T I M E M O D E T E M P P O W E R F A N S P E E D Do not under any circumstances cut or remove the grounding prong from the plug. Line Cord Plug Use Wall Receptacle Power Supply Power supply cord with 3-prong grounding plug Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use 15 AMP, time delay fuse or circuit breaker. Line [...]
-
Page 25
25 ENGLISH PREFERRED METHOD Ensure proper ground exists before use TEMPORARY METHOD Adapter plug Receptacle cover Metal screw Fig. 22 Fig. 23 25 Electrical Safety IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding)[...]
-
Page 26
26 PREFERRED METHOD Ensure proper ground exists before use Fig. 24 3-prong grounding plug Ground prong Power supply cord 3-prong grounding type wall receptacle Electrical Sa f ety ( L1804R, L W1800ER MODELS) IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this applian[...]
-
Page 27
27 ENGLISH 27 Common Pr ob lems and Solutions Common Issues Before calling for service, please review the following list of common problems and solutions. The air conditioner is operating normally when: • You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in highly humid conditions. This feature is[...]
-
Page 28
WARRANTY PERIOD: HOW SERVICE IS HANDLED: The warranted labor covers the cost of In-Home Service on all parts including the compressor. THIS LIMITED WARRANTY DOES NOT APPLY TO: CUSTOMER INTER-ACTIVE CENTER NUMBERS: To Prove Warranty Coverage To Obtain Nearest Authorized Service Center or Sales Dealer, or to Obtain Product, Customer, or Service Assis[...]