Go to page of
Similar user manuals
-
Power Supply
Liebert GXT3-10000T220
32 pages 2.05 mb -
Power Supply
Liebert PSA500MT-120
2 pages 0.89 mb -
Power Supply
Liebert GXT2-6000 RT208
52 pages 4.11 mb -
Power Supply
Liebert NXL
20 pages 0.92 mb -
Power Supply
Liebert UD600R
6 pages 0.37 mb -
Power Supply
Liebert PowerSure PS250-60S
13 pages 0.22 mb -
Power Supply
Liebert 130 kVA
102 pages 0.59 mb -
Power Supply
Liebert UPStation S VM12000
38 pages 1.23 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Liebert 350VA to 1000VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Liebert 350VA to 1000VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Liebert 350VA to 1000VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Liebert 350VA to 1000VA should contain:
- informations concerning technical data of Liebert 350VA to 1000VA
- name of the manufacturer and a year of construction of the Liebert 350VA to 1000VA item
- rules of operation, control and maintenance of the Liebert 350VA to 1000VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Liebert 350VA to 1000VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Liebert 350VA to 1000VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Liebert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Liebert 350VA to 1000VA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Liebert 350VA to 1000VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 1 Liebert PowerSure PSA UPS GUIDE SPECIFICATIONS 350VA to 1000VA Single - Phase Uninterruptibl e Power Supply System s 1.0 GENERAL 1.1 SUMMARY This specification defines the el ectrical and mechani cal characteristics and requirem ents for a continuous- duty single-phase, solid-state, u[...]
-
Page 2
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 2 B. Voltage Boost/Buck - During input power source abnormalities (sags and swells), the AC output power is corrected by means of boost (sag correction) or buck (swell correcti on) compensation taps. Operation of the compensation tap s automatically maintains the p roper output voltage [...]
-
Page 3
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 3 127 VAC nominal : single phase, 2-wire-plus-ground: 90 ─ 150 VAC (±3VAC), Buck compensation: 141VAC (±3VAC) Boost1 compensati on: 113VAC (±3VAC) Boost2 compensati on: 100VAC (±3VAC) 220 VAC nominal: single phase, 2-wire-plus-earth: 155 ─ 270 VAC (±6VAC) Buck compensation: 243[...]
-
Page 4
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 4 F. Voltage Transient Response: ±15% in Norm al mode for 0-100-0% loadi ng of the UPS rating, ±5% in Batt ery mode for 20-100-20% l oading of the UPS rating. G. Transient Recovery Time: To within ±8% of no minal voltage in < 2 cycles. H. Efficiency: >95% (Normal m ode) >90%[...]
-
Page 5
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 5 1.7 QUALITY ASSURANCE 1.7.1 Manufacturer Qualifications Liebert Corporation provides m ore than twenty years experience in the design, manufacture, and testing of solid-sta te UPS system s and the company is cert ified to ISO 9001. 1.7.2 Factory Testing Before shipment, t he product i[...]
-
Page 6
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 6 2.2.2 Bi-Directional Converter 2.2.2.1 General The Bi-Directional Converter incorporates soli d-state devices and control ci rcuitry to convert AC power to regulated DC power for bat tery charging; and convert DC power from the bat tery to regulat ed and conditione d stepped-sinewave [...]
-
Page 7
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 7 2.2.3 Display and Controls 2.2.3.1 General The UPS is provided with a m icroprocessor-based unit status and control display designed for convenient and reliabl e user opera tion. The status and al arm indicators are displayed on a stat us indicator display . 2.2.3.2 System Indicators [...]
-
Page 8
PowerSure PSA Guide Specification 350 – 1000VA SL-23271 8/03 8 2.2.6 Communications The UPS has a DB -9 (9 pin fem ale) connector on t he rear to allow UPS status com municati ons with a computer system running MultiLink™ soft ware. The DB-9 is capable of supplying serial communication, on battery and low b attery signals. MultiLink, Liebert’[...]