Go to page of
Similar user manuals
-
Network Card
Liebert EIA-485/232
2 pages 0.73 mb -
Clothes Dryer
Liebert 510 616 830
44 pages 2.99 mb -
Power Supply
Liebert Series 610
44 pages 0.66 mb -
Switch
Liebert HiSwitch2
4 pages 0.25 mb -
Power Supply
Liebert 700-3000 VA
28 pages 0.66 mb -
Power Supply
Liebert 350VA to 1000VA
8 pages 0.11 mb -
Power Supply
Liebert GXT2-6000RTL630
44 pages 4.89 mb -
MP3 Player
Liebert 600T
129 pages 3.15 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Liebert gxt2u, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Liebert gxt2u one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Liebert gxt2u. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Liebert gxt2u should contain:
- informations concerning technical data of Liebert gxt2u
- name of the manufacturer and a year of construction of the Liebert gxt2u item
- rules of operation, control and maintenance of the Liebert gxt2u item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Liebert gxt2u alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Liebert gxt2u, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Liebert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Liebert gxt2u.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Liebert gxt2u item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
AC P owe r Syste ms For Bu sines s-Critic al C ontinuity™ Lieber t ® GX T2U ™ Us er Man ual - 120V , 500-3000V A DISCONTINUED PR ODUCT[...]
-
Page 2
DISCONTINUED P R O D U C T[...]
-
Page 3
i T ABLE OF CONTENTS 1.0 G LOSSARY OF S YMB OLS . . . . . . . . . . . . . . . . . . . . . . . 3 2.0 I NTRODUCT ION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.0 M AJOR C OMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.1 Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters . . . . . . . . . . . . . . .[...]
-
Page 4
ii 6.0 O PERATING I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . 17 6.1 Normal Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . 17 6.2 Bypass Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . 17 6.3 Battery Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . 18 6.4 Battery Recharge Mode . . . . . . . .[...]
-
Page 5
1 I MPORT ANT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains importa nt safe ty instructions. Re ad all safety, installation, and o perating instruction s before opera ting the Uni nter- ruptible Power System (UPS). Adhere to all warnings on the unit and in this manual. Follow al l operating and user instructions. In dividuals [...]
-
Page 6
2 This UPS contains no user service able parts except the internal bat - tery pack. The UPS ON/Standby push buttons do not electrically iso- late internal parts. Under no ci rcumstances attempt to gain access internally other than to replace the batteries due to risk of electric shock or burn. Do not continue to use the UPS if the front panel indi-[...]
-
Page 7
Glossary of Symbols 3 1.0 G LOSSARY OF S YMBOLS Risk of electrical shock Indicates caution followed by important instructions AC input AC output Requests the user to consult the manual Indicates the unit contains a valv e-regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON Standby i DISCONTINU[...]
-
Page 8
Introduction 4 2.0 I NTRODUCTION Congratulations on your choice of the Liebert GXT2U™ Uninterrupt- ible Power System (UPS). It provides con ditioned po wer to microcom- puters and other sensitive electronic equipment. Upon generation, AC power is clea n and stable. However, during transmission and distribution it may be subject to voltage sags, s[...]
-
Page 9
Major Components 5 3.0 M AJOR C OMPONENT S 3.1 T RANSIEN T V OLT AGE S UR GE S UPPRESSION (TVSS) AND EMI/RFI F ILTERS These UPS components provide surge protection and filter both elec- tromagnetic interference (EMI) an d radio frequency interference (RFI). They minimize any surges or int erference present in t he utility line and keep the sensitiv[...]
-
Page 10
Major Components 6 3.4 B ATTERY C HARGER The battery charger uti lizes energy from the utility po wer and pre- cisely regulates it to contin uously “float charge” the batteries. The bat- teries are being charged whenev er the Liebert GXT2U is plugge d in, even when the UPS is not turned on. 3.5 DC TO DC C ONVERTER The DC to DC converter utilize[...]
-
Page 11
Major Components 7 3.8 L IEBERT GXT2U, R EAR V IEW Rev . USBCARD Input Fuse / Circuit Breaker AC Input Support Base Output Receptacles External Battery Connector Cooling Fa n USB card be ing fitted in Liebert Intel liSlot ® Port DB-9 Communicat ions Port DISCONTINUED P R O D U C T[...]
-
Page 12
Installation 8 4.0 I NST ALLATION 4.1 P REP ARATION 1. Visually inspect the UPS for fr eight damage. Report damage to the carrier and your local deal er or Liebert representative. 2. Decide where to place the Lieber t GXT2U. Install the UPS indoors in a controlled environment, wh ere it cannot be accidentally turned off. Pla ce it in an area of unr[...]
-
Page 13
Installation 9 4.3 R ACK -M OU NT UPS C ONVERSION AND I NSTALLATION 1. For slide rail install ations, first remove the top/side fin. Slide the top/side fin forward, then lift it up to remove. If d esired, install the optional rack mount handles th at were shipped wi th the UPS. Securing hardware and slide rails are sold separately. Contact your loc[...]
-
Page 14
Installation 10 3. Determine the height position inside the rack enclosure where you want to mount the UP S or battery cabinet. Install rear member of each bracket assembly into rack enclosure with two (2) M5 screws provided in this kit. (See figure at right.) Return flanges on bracket assembly fit to the inside of rack mounting rails. Insert screw[...]
-
Page 15
Installation 11 5. Prepare the UPS or battery cabinet (the “equipment”) for rack mounting by following instructions in the equipment’s user manual. The equipment may require addi tional parts to be added or pa rts to be removed for rack mounting. After it is prepared, lay equipment in rack-mounting position. Fasten inner members from Step 2 t[...]
-
Page 16
Installation 12 8. Secure front of the equipment to rack mounting rails to prevent the equipment from sliding out of position. If secu ring holes are provided on front of the equipment that align with the center holes on return flange of front members, you can use the four (4) extra M5 screws provided in this kit to secure the equipment. Otherwise,[...]
-
Page 17
Installation 13 4.4 E XTERNAL B ATTERY C ABIN ET I NST ALLATION Optional Liebert external batt ery cabinets may be connected to the UPS to provide additional battery run ti me. External battery cabinets are designed to be placed all on one si de of the UPS or stacked beneath the UPS. There is no limit to the number of external battery cabinets that[...]
-
Page 18
Controls and In dicators 14 5.0 C ONTROLS AND I NDICATORS 5.1 ON/A LARM S ILENCE /M ANUAL B ATTERY T EST B UTTON This button controls output power to connected load(s) and has three functions: • ON • Alarm Silenc e • Manual Battery Test ON - Pressing this button will start up the UPS in or der to provide conditioned and protected powe r. Alar[...]
-
Page 19
Controls and In dicators 15 5.2 S T ANDB Y /M ANUA L B YP ASS B UTTON This button controls output power to connected load(s) and has dual functions : Standby and Manua l Bypass. 5.3 L OAD /B ATTERY L EVEL I NDICATORS (4 G RE EN , 1 A MBER ) The load/battery level indicators have dual functions. During normal mode operati on LED indicators di splay [...]
-
Page 20
Controls and In dicators 16 5.8 AC I NPUT I N DICATOR L ED (G REEN ) The AC Input indicator LED is il luminated when utilit y power is available and within the inpu t specifications. 5.9 O UTPUT V OLT AGE S ELECTION The Output Voltage is user configurab le and is designed to al low selecting or changing the desired ou tput voltage to match the util[...]
-
Page 21
Operating Instructions 17 6.0 O PERATING I NSTRUCTIONS 6.1 N ORMAL M ODE O PERATION During normal operation, utility power provides energy to the UPS. The filters, power factor correction circuit and the inverter process this power to provide computer grade power to connected loads. The UP S maintains the batteries in a fully charged state. The fou[...]
-
Page 22
Operating Instructions 18 6.3 B ATTERY M ODE O PERATION Battery mode occurs in event of an extreme input voltage condition or com- plete utility fail ure. The battery system supplies power through the DC to DC converter to the inverter to generate power for the connected load. During battery mode an al arm sounds every 10 seconds. This will change [...]
-
Page 23
Communications 19 7.0 C OMMUNICATIONS 7.1 C OMMUNICATIONS I NTERFA CE P ORT The Liebert GXT2U UPS has a standard DB-9 serial port female con- nector located on the rear of th e UPS unit. Several s ignals are pro- vided on this port and are assigned as fo llows: * Maximum voltage and current on pins 1, 7, 8, and 9 is 60 VDC ; 10.0 mA. Pin Assignment[...]
-
Page 24
Communications 20 7.2 P INS 4 & 5 - R EMOTE S HU T DOWN ON B ATTERY 1. This pin is functional only when th e UPS is in battery m ode. If the UPS is bein g powered by the utility , Pin 4 will i gnore any sig nal on this pin. 2. Pin 4 requires a 5- 12 VDC signal to shutdown. This normally comes form the serial port using Li ebert’s contact clos[...]
-
Page 25
Communications 21 7.3 P INS 5 & 6 - A NY -M ODE S HU T DOWN 1. Pin 6 of the 9-pin communication connector is used for “Any-Mode Shutdown” of the UPS output. This con trol input may be used in special applications to disable the UPS output power—both Inverter and Bypass. 2. The Options tab allows the beha vior of the Any-Mode Shutdo wn fea[...]
-
Page 26
Communications 22 7.4 UPS I NTELLIGENT C OMMUNI CATIONS The Liebert GXT2U is equipped with a Liebert IntelliSlot ® port to pro- vide advanced communica tion and monitoring options. Liebert’s MultiLink software continually monitors the UPS and can shut down your computer or server in the event of an extended power failure. Liebert MultiLink can a[...]
-
Page 27
Configuratio n Program 23 8.0 C ONFIGURATION P ROGRAM The configuratio n program inclu ded with the Liebert GXT2U line allows modification of several UPS settings tha t were previously unavailable or required custom manufacturing. The user manual on the configuration progra m disk describes the features availabl e for modification, as well as defau[...]
-
Page 28
Mainten ance 24 9.0 M AINTENANCE The Liebert GXT2U requires very little maintenance. The batteries are valve-regu lated, nons pillable , lead acid an d should be kept charged to obtain th eir designed life. The UPS con tinuously charg es the batteries when connected to the utility supply . When storing the UPS for any length of time, it is recommen[...]
-
Page 29
Mainten ance 25 9.1.1 Internal Battery Replacement Proc edures 1. Gently remove the front plastic bezel cover from the UPS. 2. Loosen and remove the four scre ws on the front battery door. Lay the battery door as ide for reassembly. Note: The 3000VA model includes a pull handle to remove this door. It has two built-in connectors that disconnect wh [...]
-
Page 30
Mainten ance 26 9.2 F USE R EPL ACEMENT 1. Remove the input fuse. 2. Locate the spare input fuse that is included with the UPS. 3. Insert the spare fuse into the fuse holder, and reinstall assembly into the UPS. Twist by hand; rotate clockwise unti l fuse holder locks into position . 4. Reconnect the input power cord to input AC supply. 5. Restart [...]
-
Page 31
Troubleshooting 27 10.0 T ROUB LESHOOTING The information below indicates various symptoms a user may encounter in t he event the Liebert GXT2U develops a prob lem. Use this information to determin e whet her external factors caused the problem and how to re medy the situation. 1. The Fault indicator will illuminate, indicating the UPS detected a p[...]
-
Page 32
Troubleshooting 28 Under fault conditi ons, the Fault indi cators will be il luminated indefi- nitely while battery charger is operational, or for a maximum of 5 min- utes while ba ttery charger is not oper ational. If a problem persists, consult your local dealer, Liebert representative or contact the Liebert Worldwide Su pport Group. Please have [...]
-
Page 33
Troubleshooting 29 Fault and Bypass indicator LEDs and all load l evel LEDs are illuminated. UPS overloaded or lo ad equipment is faulty. Check load level display and remove non-e ssential loads. Recal culate the loa d and reduce numb er of loads connected to UPS. Check load equipment for faults. Fault and Bypass indicator LEDs and diagnostic LED A[...]
-
Page 34
Troubleshooting 30 Fault and Bypass indicator LEDs and diagnostic LED C and E are illuminated. UPS shutdown due to a command from the communications port(s). Your UPS has received a signal or command from the attached computer. If this was inadvertent, ensure the communication cable used is correct for your system. For assistance, contact your loca[...]
-
Page 35
Troubleshooting 31 T able 2 Alarm conditions Condition Alarm Battery Mode (utility failure) One short beep every 10 seconds; more than 2 minutes of run time remaining Low Battery Two short beeps every 5 seconds; less than 2 minutes of run time remaining Output Overloa d (bypass) One short beep every half second Overtempera ture (bypass) A one-secon[...]
-
Page 36
Specifications 32 11 . 0 S PECIFICATIONS Model Number GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 Model Rat ing 500V A/35 0W 700V A / 490W 1000V A / 700W DIMENSIONS - in. (mm) Unit W x D x H 3.5 x 21.5 x 17 (87 x 547 x 430) 3.5 x 21.5 x 17 (87 x 547 x 430) 3.5 x 21.5 x 17 (87 x 547 x 430) Shipping W x D x H 10.6 x 27.2 x 23 (269 x 691 x 584) 10.6 x [...]
-
Page 37
Specifications 33 S PECIFICATIONS ( CONTINUED ) Model Number GXT2-1500RT120 GXT2-2000RT120 GXT2-3000RT120 Model Rating 1500V A / 1050W 2000V A / 1400W 3000V A / 2100W DIMENSIONS - in. (mm) Unit W x D x H 3.5 x 21.5 x 17 (87 x 547 x 430) 3.5 x 21.5 x 17 (87 x 547 x 430) 3.5 x 24.2 x 17 (87 x 618 x 430) Shipping W x D x H 10.6 x 27.2 x 23 (269 x 691 [...]
-
Page 38
Battery Cabinet Specifications 34 12.0 B ATTERY C ABINET S PECIFICATIONS Model Number GXT2-48VBA TT GXT2-72VBA TT Used With UPS Model GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 GXT2-1500RT120 GXT2-2000RT120 GXT2-3000RT120 DIMENSIONS - in. (mm) Unit W x D x H 3.5 x 21.5 x 17 (87 x 547 x 4 30) 3.5 x 24.2 x 17 (87 x 618 x 430) Shipping W x D x H 10.5 [...]
-
Page 39
Battery Run Times 35 13.0 B ATTERY R UN T IMES Load% 500VA 700VA 1000VA 1500VA 2000VA 3000VA Internal Battery (minutes) 10% 494 248 191 144 56 91 20% 181 115 87 53 33 46 30% 107 79 48 38 26 30 40% 83 58 34 28 19 21 50% 66 44 25 20 14 16 60% 53 35 19 15 12 11 70% 44 29 16 12 10 9 80% 36 24 13 10 8 8 90% 31 20 12 8 7 7 100% 28 17 11 7 6 5 Internal Ba[...]
-
Page 40
Product Warranty Registration 36 14.0 P RODUCT W ARRANTY R EGISTRATION To register for warranty protection: • Visit the Quick Links section of our Web site at: http://www.liebert.com • Click on Product Warranty Registration and fill in the form. If you have any questions, please contact us a t: US: 800-222 -5877 Outside the US: 614-841-67 55 up[...]
-
Page 41
NOTES DISCONTINUED P R O D U C T[...]
-
Page 42
DISCONTINUED P R O D U C T[...]
-
Page 43
DISCONTINUED P R O D U C T[...]
-
Page 44
Ensuring The High A vaila bilit y 0f Mission-Critic al Dat a And Appli c ations. While every precaution has been tak en to ensure the accuracy and complet eness of this lite rature, Liebe rt Corporation assumes no responsibility and disclaims all liability for damages resulting from u se of this inform ation or for any errors or omissions . © 2007[...]