Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V should contain:
- informations concerning technical data of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V
- name of the manufacturer and a year of construction of the Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V item
- rules of operation, control and maintenance of the Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Liebert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Liebert PowerSure PSI 1000 - 3000VA 60 Hz 120V item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Power Pr otec ti on fo r Business Critical Continuity Li eb er t P o wer S u re P SI ™ User Ma nual 1000 - 3000V A, 60 Hz, 120V[...]

  • Page 2

    [...]

  • Page 3

    i T ABLE OF CONTENTS I MPORT ANT S AFETY I NSTRUCTIO NS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.0 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.0 I NTRODUCTI ON . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 4

    ii 7.2 Buck/Boost Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 7.3 Battery Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7.4 Battery Recharge Operation . . . . . . . . . . . . . . . .[...]

  • Page 5

    iii FIGURES Figure 1 Front view of UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2 1000 and 1440VA PSI—rear view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 3 1920 and 2200VA PSI—rear [...]

  • Page 6

    iv[...]

  • Page 7

    1 I MPORT ANT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual co ntains important sa fety instructions that should be followed durin g the installati on and maintenance of the UPS and batt eries. Please re ad this manual th oroughly be fore attempting to install or operate this UPS. CONDITIONS OF USE: The input receptacle must be within [...]

  • Page 8

    2 ! CAUTION BATTERY HANDLING PRECAUTIONS Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and re quired precautio ns. Keep unauth orized personnel away from the ba tteries. A battery can present a risk of electrical shoc k and high short-circuit current. The following precaution s should be observed w[...]

  • Page 9

    Glossary of Symbols 3 1.0 G LOSSARY OF S YMBOLS . Risk of ele ctrical shock Indicates caution followed by important instructions Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON/Alarm Silence/Battery Test OFF Voltag[...]

  • Page 10

    Introd uction 4 2.0 I NTRODUCTION Congratulations on your choice of the Liebert Po werSure™ PSI Uninterruptible Power Supply (UPS). It provides conditioned power to microcomput ers and other sensitive electronic equipment. Upon generation, AC power is clea n and stable. However, during transmission it may be subject to voltage sags, s pikes, or c[...]

  • Page 11

    Introd uction 5 Figure 2 1000 and 1440V A PSI—rear view Figure 3 1920 and 2200V A PSI—rear view Figure 4 3000V A PSI—rear view INPUT INPUT BREAKER PUSH TO RESET PHONE / FAX / MODEM / NETW ORK PROTECTION BA TTERY CONNECTOR 1440VA/DC 48V/30A 1000VA/DC 48V/20A 1 2 3 4 INTELLISLOT LOAD 2 LOAD 1 IN OUT + - REPO RS-232 Data Line Connectors Circuit [...]

  • Page 12

    Major Compo nents 6 3.0 M AJOR C OMPONENT S Figure 5 Line diagram of Power Sure PSI 1000V A & 1440V A Figure 6 Line diagram of Power S ure PSI 1920V A, 2200V A & 3000V A 3.1 T ransient V olt ag e Surge Suppr ession (TVSS) and EMI/RFI Filters These UPS components provide surge protection and filter both elect romagnetic interference (EMI) an[...]

  • Page 13

    Major Compo nents 7 3.3 Automatic V oltage Regulator The Automatic Voltage Regulator ( AVR) protects connected equipmen t from power spikes, sa gs and other abnormalitie s by raising (b oosting) or loweri ng (bucking) the output voltage as needed . This keeps the UPS output voltage wi thin the connected equipment’s tolerance and accommodates wide[...]

  • Page 14

    What’ s Included 8 4.0 W HAT ’ S I NCLUDED The PowerSure PSI is shipped with the following items: • PowerSure PSI user manual • Warranty card • MultiLink software CD • MultiLink serial cable, 10 ft (3 m) • USB cable, 6 ft (1.8m) • RJ-11 cord, 7 ft (2.1m) • Rack mount handles • Support base • Fixed rails • Mounting hardware ([...]

  • Page 15

    Installation 9 5.0 I NST ALLATION 5.1 Prep aration 1. Visually inspect the UPS for freight damage. Report damage to the carrier an d your local dealer or Liebert representative. 2. Decide where to place the PowerSure PSI. Inst all the UPS indoors in a cont rolled environment where it cannot b e accidentally tu rned Off. Place it i n an area of un r[...]

  • Page 16

    Installation 10 5.3 Rack-Mount U PS Conversion and Inst allation 1. For fixed rail installations, install the rack mount handles using four (4) M4x6 screws (see Figure 8 ). Figure 8 Rack mount handles 2. Unpack the two fixed rail assemblies and mounti ng hardware. Loosen the wi ng nuts and extend the inner members to their outermost position (see F[...]

  • Page 17

    Installation 11 4. Attach the two (2) fixed rails to the racks mounting ra ils. The fi xed rail asse mblies fit on the inside of the ra ck mounting rails. 5. Insert two (2) M5 flat head screws loosely (f inge r-tight) into the top and bottom holes on the front of the fix e d rail assemb ly (see Figure 10 ). 6. Extend f ixed rail by sl iding inner m[...]

  • Page 18

    Installation 12 13. Connect Phone/Fax/DSL/Network/Mode m devices to data line connectors. 14. Communication options (see 8.0 - Comm unications for details): Option 1 - Serial Communications Serial communications provides pa rametric data, for example, in put voltage and ba ttery voltage. a. Connect MultiLink serial cable included with the UPS to co[...]

  • Page 19

    Installation 13 Figure 1 1 REPO switch connections 5.4 External Battery Cabinet Inst allation Optional Liebert external battery cabinets may be connec ted to the UPS to prov ide additional battery run time. External battery cabinets are designed to be pla ced all on one side of the UPS or stacked beneath the UPS. The run time is limi ted to a maxim[...]

  • Page 20

    Controls and Indica tors 14 6.0 C ONTROLS AND I NDICATORS 6.1 ON/Alarm Silence/ Battery T est Button This button controls output power to co nnected lo ad(s) and has th ree functions: •O n • Alarm Silence •B a t t e r y T e s t ON —When the UPS is Off, pressing the ON/Alarm Silence/Battery Test button for more than on e (1) second will star[...]

  • Page 21

    Controls and Indica tors 15 6.3 V oltage Programming Button The PowerSure PSI contains a Volt age Programming button that a llows the operator to select the nominal utility voltage. Th is setting changes the utility transfer points (low an d high) of the UPS and the nominal output voltage when operating in Ba ttery mode. The operator can select bet[...]

  • Page 22

    Controls and Indica tors 16 6.9 Over T emp Indicator—Amber The Over Temp Indicator flashes wh en the UPS detects an over temper ature condition. This indicator illuminates when the UPS sh uts down due to an over temperature condition (see Troubleshooting section for details). 6.10 Fault Indicator—Red The Fault Indicator illumina tes when the UP[...]

  • Page 23

    Modes of Operati on 17 7.0 M ODES OF O PERATION 7.1 Normal Mode During Normal mode operation, the Po werSure PSI supplies conditioned, co mputer- grade power to the connected equipment: utility power passes th rough the TVSS circuitry and the EMI/RFI filters and then through the Inverter (1000VA & 1440 VA) / Bi-Directional Converter (1920VA, 22[...]

  • Page 24

    Modes of Operati on 18 7.3 Battery Mode The UPS switches to Battery mode in the event of an extreme input voltage/frequency condition or complete utili ty failure. The battery system su pplies power th rough the Inv erter (1000VA & 14 40VA) or through the DC-to-DC conve rter to the Bi-Dir ectional Converter (1920, 2200VA and 3000VA) to generate[...]

  • Page 25

    Communications 19 8.0 C OMMUNICATIONS 8.1 DB-9 Connector The UPS has a DB-9 (9 pin female) connector on the re ar to allow UPS status comm unications with a computer system running Mu ltiLink software. The DB-9 is capa ble of supplyin g serial communi ca- tion, on battery and low battery signals. MultiLin k, Liebert’s UPS monitori ng an d shutdow[...]

  • Page 26

    Communications 20 8.3 USB Interface Port The PowerSure PSI has a USB interface port for co mmunication that will wo rk with the built-in Microsoft Power Manger software on the user’s PC , if so equipped. It will pro vide UPS status and manages the automatic orderly shutdown of the computer. The UPS’s USB communications meet HID standard, v ersi[...]

  • Page 27

    V oltage Programming Procedure 21 9.0 V OLT AGE P ROGRAMMING P ROCE DURE Figure 18 Load Level Indicators 1. Remove the front bezel from the UPS. 2. UPS must be o perating in No rmal (AC) mod e. 3. The AC Input, Load, and Battery Level Indicators should be lit. 4. Press the Voltage Programming button for at le ast 5 seconds to enter the Configuratio[...]

  • Page 28

    Maintenance 22 10.0 M AINTENANCE The PowerSure PSI UPS requires very little mainte nance. Follow these practices to prevent prob- lems. 10.1 Cleaning the UPS The following will help ensure trouble-free operation for years: • Vacuum dust from the ventil ation intake occasionally. • Wipe the cover periodically with a dry cloth. 10.2 Maint aining [...]

  • Page 29

    Maintenance 23 10.3.1 Internal Battery Replacement Proce dure 1. Gently remove the front plas tic b ezel cove r from t he UPS. 2. Loosen and remove the five (5) screws on the front cover plate. Lay the cover pl ate aside for reassembly. 3. Loosen and remove four (4) screws on battery bracket. 4. Disconnect the two (2) slotted, red and bl ack batter[...]

  • Page 30

    Trou bleshooting 24 11 . 0 T ROUBLESHOOTING The information below indicates va rious symptoms a user may encount er in the event the PowerSure PSI experiences a problem. Use this information to determine w hether external factors caused the problem. See Table 2 - Troubleshooting chart for suggested remedy. 1. An alarm sounds, alerting that the UPS [...]

  • Page 31

    Trou bleshooting 25 T able 2 T roubleshooting chart Problem Cause Solution UPS will not start Short circuit Check the circuit protector on the rear of the U PS. If it is tripped, reset it and restart the UPS. For further help, contact your local dealer, Liebert representative or the Li ebert Worldwi de Support Group. Battery disco nnected or is com[...]

  • Page 32

    Specifications 26 12.0 S PECIFICATIONS T able 3 UPS specifications Model Number PS1000RT2- 120 PS1440RT2-120 PS1920RT2 -120 PS2200RT2- 120 PS3000RT2- 120 Power Rating, VA/W 1000VA/750W 1440VA/1080W 1920VA/1500W 2200VA/1650W 3000VA/2250W Dimensions , W x D x H, in (mm) Unit 3.43 x 22 x 17 (87 x 557 x 430) 3.43 x 22 x 17 (87 x 557 x 430) 3.43 x 24.1 [...]

  • Page 33

    Specifications 27 Agency Safety UL 1778, c-UL Listed Surge ANSI C62.41, Category A, Level 3 (IEEE 587, Category A); EN61000-4-5, Level 3, Criteria B ESD EN61000-4-2, Level 3, Criteria B Susceptibility EN61000-4-3, Level 3, Criteria A Electrical Fast Transient EN61000-4-4, Level 4, Criteria A Emissions FCC Part 15, Cla ss B FCC Part 15, Class A Cond[...]

  • Page 34

    Specifications 28 T able 5 Battery run ti mes Load% 1000VA 1440VA 1920VA 2200VA 3000VA Internal Battery (minutes) 5% 174 138 181 171 177 10% 118 79 104 73 91 2 0 % 6 54 55 24 74 7 3 0 % 4 12 83 12 62 8 4 0 % 3 72 42 52 32 2 5 0 % 2 61 61 91 61 6 6 0 % 2 41 41 51 31 4 7 0 % 1 81 01 11 01 0 8 0 % 1 691 08 9 90% 12 6 8 6 7 100% 11 5 6 5 6 Internal Bat[...]

  • Page 35

    Specifications 29 12.1 Product W arranty Registration To register for warranty protection, visit the Quick Links section of our Web site at: www .lieb ert.com Click on Product Warranty Registration and complete the form. If you have any questions, please contact us at: US: (800) 222-587 7 Outside the US: (614) 841 -6755 E-Mail: up stech@liebert. co[...]

  • Page 36

    Emerson Net work P ower . The global leade r in enabling Busines s-Critical Continuit y . EmersonNetworkPow er .com Emerson Network Powe r and the Emerson Net work Powe r logo are tradem arks and service marks of Eme rson Electric Co. ©2005 Emerso n Electric Co. The Company Behind the Produc ts With ov er a million in stallations aro und the globe[...]