Lincoln Electric RANGER GXT IM856 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lincoln Electric RANGER GXT IM856, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lincoln Electric RANGER GXT IM856 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lincoln Electric RANGER GXT IM856. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lincoln Electric RANGER GXT IM856 should contain:
- informations concerning technical data of Lincoln Electric RANGER GXT IM856
- name of the manufacturer and a year of construction of the Lincoln Electric RANGER GXT IM856 item
- rules of operation, control and maintenance of the Lincoln Electric RANGER GXT IM856 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lincoln Electric RANGER GXT IM856 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lincoln Electric RANGER GXT IM856, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lincoln Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lincoln Electric RANGER GXT IM856.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lincoln Electric RANGER GXT IM856 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    RANGER ™ GX T OPERA TOR’S MANUAL For Machines with Code Number 11154 IM856 May, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS E[...]

  • Page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________[...]

  • Page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin[...]

  • Page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C[...]

  • Page 5

    Mar. ‘93 iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les[...]

  • Page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay[...]

  • Page 7

    vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................................................................A-1 Safety Precautions .............................[...]

  • Page 8

    A-1 INST ALLA TION RANGER GXT A-1 TECHNICAL SPECIFICA TIONS - Ranger GXT (K2382-1 ) INPUT - GASOLINE ENGINE RA TED OUTPUT @ 104°F (40°C)- WELDER HEIGHT WIDTH DEPTH WEIGHT 30 in.** 21.5 in. 42.25 in. 762 mm 546 mm 1073 mm RA TED OUTPUT @ 104°F (40°C)- GENERA TOR Welding Output AC Constant Current 250A / 25V / 100% DC Constant Current 250A / 25V [...]

  • Page 9

    A-2 INST ALLA TION RANGER GXT A-2 SAFETY PRECAUTIONS MACHINE GROUNDING Because this portable engine driven welder or genera- tor creates it’s own power, it is not necessary to con- nect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.). To prevent dangerous electric shock, other equip- men[...]

  • Page 10

    FUEL Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling. OIL The RANGER GXT is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Make cer- tain that the oi[...]

  • Page 11

    A-4 INST ALLA TION RANGER GXT A-4 WELDING OUTPUT CABLES With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary. Loose connections will result in overheating of the output studs. When welding at a considerable distance from the welder, be sure yo[...]

  • Page 12

    A-5 INST ALLA TION RANGER GXT A-5 LOCA TION / VENTILA TION The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder so that engine exhaust fumes are properly vented to an outside ar[...]

  • Page 13

    A-6 INST ALLA TION RANGER GXT A-6 120 V DUPLEX RECEPTACLES The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current load through the associated receptacle. MOTOR STARTI[...]

  • Page 14

    A-7 INST ALLA TION RANGER GXT A-7 TABLE lll ELECTRICAL DEVICE USE WITH THE RANGER GXT. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker. Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage appliances with electrical control.[...]

  • Page 15

    A-8 INST ALLA TION RANGER GXT A-8 STANDBY POWER CONNECTIONS The RANGER GXT is suitable for temporary, standby, or emergency power using the engine manufacturer ’ s recommended maintenance schedule. The RANGER GXT can be permanently installed as a standby power unit for 240V-3 wire, single phase 42 ampere service. (Connections must be made by a li[...]

  • Page 16

    240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS. 240 VOLT GROUNDED CONDUCTOR 50 AMP 240 VOLT DOUBLE POLE CIRCUIT BREAKER DOUBLE P[...]

  • Page 17

    WELDER CONTROLS - FUNCTION AND OPERA TION ENGINE SWITCH The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine. When placed in the “ OFF ” position, the ignition circuit is de-energized to shut down the engine. When held in the “ START ” position, the engine starter moto[...]

  • Page 18

    “ RANGE ” SWITCH The “ Range ” switch is used to select one of four amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range. Never change the “ RANGE ” Switch setting while welding. This will damage the switch. ------------------------------------------------------------------------ “ CONTROL ” DI[...]

  • Page 19

    B-3 OPERA TION B-3 ST ARTING/SHUTDOWN INSTRUCTIONS STARTING THE ENGINE Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner ’ s Manual before starting for the first time. Remove all loads connected to the AC power recepta- cles. Use the choke control as follows: KOHLER ENGINE - Always pull the choke control out [...]

  • Page 20

    B-4 OPERA TION B-4 WELDING PROCESS For any electrodes the procedures should be kept within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication. STICK (CONSTANT CURRENT) WELDING Connect welding cables to the "TO WORK ” and "ELECTRODE ” studs. Start the engine. Set the "Polarity ” switch[...]

  • Page 21

    B-5 OPERA TION B-5 RANGER GXT SUMMARY OF WELDING PROCESSES CONTROL ELECTRODE CABLE IDLE WHEN NOT TO START PROCESS USED MODE WELDING WELDING STICK No AUTO Hot Touch electrode to work. Welding starts immediately and engine goes to high idle. WIRE FEED, LN-25 WITH No AUTO Cold Press gun trigger, LN-25 INTERNAL CONTACTOR contactor closes. Welding start[...]

  • Page 22

    C-1 ACCESSORIES C-1 RANGER GXT OPTIONAL EQUIPMENT (Field Installed) K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.) Order K957-1 Trailer K958-1 Ball Hitch K958-2 Lunet[...]

  • Page 23

    C-2 ACCESSORIES C-2 RANGER GXT RECOMMENDED EQUIPMENT STICK K704 Accessory Kit which includes: • Electrode Holder & Cable • Work Clamp & Cable • Headshield WIRE FEED K449 LN-25 - Includes internal contactor for across the arc operation (no control cable). Provides “ cold ” electrode until gun trigger is pressed. Includes gas soleno[...]

  • Page 24

    Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete. Always use the greatest care when working [...]

  • Page 25

    D-2 MAINTENANCE D-2 Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH. SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C). See Engine Owner ’ s Manual f[...]

  • Page 26

    D-3 MAINTENANCE D-3 ENGINE ADJUSTMENTS OVERSPEED IS HAZARDOUS The maximum allowable high idle speed for this machine is 3750 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum. ---[...]

  • Page 27

    E-1 TROUBLESHOOTING E-1 RANGER GXT If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair possi[...]

  • Page 28

    E-2 TROUBLESHOOTING E-2 RANGER GXT Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SY[...]

  • Page 29

    E-3 TROUBLESHOOTING E-3 RANGER GXT Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SY[...]

  • Page 30

    F-1 DIAGRAMS F-1 RANGER GXT NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.[...]

  • Page 31

    F-2 DIAGRAMS F-2 RANGER GXT RANGER GXT / L N-25 OR LN- 15 ACROSS THE ARC CONNECTI ON DI AGRAM TO WORK ELECTROD E TO W ORK LN-25 OR LN-15 WI RE FEEDE R ELECT RODE CABL E W ORK CLIP LE AD N.A. WELDING CABLE MU ST BE SIZ ED FOR CURR ENT AND DUTY CYCL E OF APPLI CATION. N.B. USE POL ARITY SW ITCH TO SE T FOR DESI RED ELECT RODE POL ARITY. POSITIO N THE[...]

  • Page 32

    F-3 DIAGRAMS F-3 RANGER GXT M20512 A.01. 41.2 0 17.5 0 19.5 0 42.1 0 20.8 0 21.0 0 14.7 5 33.6 2 36.2 4 TRUC K/U ND ERC ARR IAG E MOU NTING HOLE S 24.8 6 2.6 7.22 10.2 8 10.7 8 29.8 8 CE NTER OF GR AVITY WITH OIL IN E NGIN E A ND EM PTY FUEL TA NK.[...]

  • Page 33

    NOTES RANGER GXT[...]

  • Page 34

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA E[...]

  • Page 35

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes [...]

  • Page 36

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products •[...]