A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lincoln Electric TIG 275, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lincoln Electric TIG 275 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lincoln Electric TIG 275. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lincoln Electric TIG 275 should contain:
- informations concerning technical data of Lincoln Electric TIG 275
- name of the manufacturer and a year of construction of the Lincoln Electric TIG 275 item
- rules of operation, control and maintenance of the Lincoln Electric TIG 275 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lincoln Electric TIG 275 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lincoln Electric TIG 275, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lincoln Electric service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lincoln Electric TIG 275.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lincoln Electric TIG 275 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRECISION TIG 275 OPERA T OR’S MANUAL IM908 October , 2006 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READING [...]

  • Page 2

    FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. _______________________________________________[...]

  • Page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin[...]

  • Page 4

    FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical[...]

  • Page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits [...]

  • Page 6

    v SAFETY v[...]

  • Page 7

    vi SAFETY vi[...]

  • Page 8

    vii vii Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference.[...]

  • Page 9

    T ABLE OF CONTENTS Page . Installation ..........................................................................................................Section A T echnical Specifications ........................................................................................A-1,A-2 Safety Precautions .. ...................................................[...]

  • Page 10

    A-1 INST ALLA TION PRECISION TIG 275 A-1 TECHNICAL SPECIFICA TIONS- PRECISION TIG 275 (K1827-2 Export-50/60Hz) V oltage + 10% 220-230/ 380-400/415 Max. Amps W ith Out Power Factor Capacitor 95/55/50 109/63/58 80/46/42 85/49/45 70/41/37 65/38/35 10/6/5 400W Max. Amps W ith Power Factor Capacitor 80/46/43 86/50/46 64/37/34 67/39/36 52/30/28 46/27/25 [...]

  • Page 11

    K1827-2 A-2 INST ALLA TION PRECISION TIG 275 A-2 ADDITIONAL OUTPUT CAP ACITY Output Current Range 2Amps DC to 340Amps AC-DC * T ype of Output CC (Constant Current) AC/DC (GT AW) Stick (SMA W) Maximum Open Circuit V oltage (STICK AND TIG) AC/DC OCV : 75/68 Auxiliary Power 15Amp Circuit Breaker and NEMA 5-15R Duplex Receptacle for up to: 1 15V AC 8Am[...]

  • Page 12

    A-3 INST ALLA TION PRECISION TIG 275 A-3 SAFETY PRECAUTIONS SELECT SUIT ABLE LOCA TION Place the welder where clean cooling air can freely cir- culate in through the top rear vents and out through the bottom rear vents. Dirt, dust or any foreign material that can be drawn into the welder should be kept at a minimum. Failure to observe these precaut[...]

  • Page 13

    INPUT and GROUNDING CONNECTIONS Be sure the voltage, phase, and frequency of the input power is as specified on the rating plate, located on the rear of the machine. Fuse the input circuit with the recommended super lag fuses or delay type1 circuit breakers. Choose an input and grounding wire size according to local or national codes or use Section[...]

  • Page 14

    A-5 INST ALLA TION PRECISION TIG 275 A-5 Recommended Cable Sizes for Combined Lengths of Copper Work and Electrode Cables using 75 o C Wire: Machine Rating 0 to 100 Ft . 101 to 200 Ft 201 to 250 Ft 275A/40% #1 (42.4 mm 2 ) 1/0 (53.5 mm 2 ) 2/0 (67.4 mm 2 ) WORK CABLE CONNECTION A1 5 ’ (2/0) weld cable with clamp is available (K2150-1), or include[...]

  • Page 15

    A-6 INST ALLA TION PRECISION TIG 275 A-6 TIG TORCH CONNECTION The Precision TIG torch connection box, located on the right side of the machine, provides all the input and output connections for the installation of both air- cooled and water-cooled TIG torches with fittings con- forming to Compressed Gas Association (CGA) stan- dards: Note: The Prec[...]

  • Page 16

    A-7 INST ALLA TION PRECISION TIG 275 A-7 AUXILIAR Y POWER CONNECTIONS The Precision TIG machines provide a standard NEMA 5-15R duplex receptacle, located on the upper case back on the torch side of the machine: • The bottom outlet of this duplex receptacle provides switched 1 15V AC power for the Under-Cooler , or W ater Solenoid accessory . This[...]

  • Page 17

    A-8 INST ALLA TION PRECISION TIG 275 A-8 ROBOTIC INTERF ACE CONNECTION Robotic interface can be made at the Remote Receptacle (See Operation Section B-2). The machine is shipped with the remote receptacle circuit internally connected to receptacle J5 of the Control board for standard Amptrol operation. In order to enable the remote receptacle for r[...]

  • Page 18

    B-1 OPERA TION B-1 PRODUCT DESCRIPTION The Precision TIG 275 is part of a new family of indus- trial arc welding power sources providing constant cur- rent, single range square wave AC/DC TIG (GT A W) with new patented (pending) Micro-Start TM T echnology , Presettable Min. and Max. Output controls, and built-in high frequency stabilization for con[...]

  • Page 19

    B-2 OPERA TION B-2 RECOMMENDED PROCESSES AND EQUIPMENT RECOMMENDED PROCESSES The Precision TIG 275 is recommended for the TIG (GT AW) and Stick (SMA W) welding processes within its output capacity range of 2 amps DC, or 5 amps AC, to 340 amps AC/DC. It is compatible with most Magnum TIG accessories (refer Equipment Limitations), as well as many ind[...]

  • Page 20

    B-3 OPERA TION B-3 1. POWER SWITCH - Input line switch turns input power ON or OFF , as indicated by the on or off sta- tus of the front panel displays. 2. POLARITY SWITCH – The 3-position rotary power switch has detente positions for DC-, AC and DC+ selections for the Electrode output welding polarity . 3. MODE SWITCH – The mode switch allows [...]

  • Page 21

    B-4 OPERA TION B-4 • When the Polarity Switch is set to DC (- or +), the TIG mode provides high frequency only for starting. Hi-Freq. turns on after pre-flow time with the arc start switch closure, and turns off when the arc is established* • Also functions for DC+ polarity to permit "balling" of tungsten for AC TIG welding. 4. AC BAL[...]

  • Page 22

    B-5 OPERA TION B-5 8. DIGIT AL METER AND DISPLA Y SWITCH – A3 - digit LED meter is used to monitor the preset and actual welding procedure based on the Display (momentary) switch position: • Before welding with Display switch in center (nor- mal) position, the digital meter displays the preset welding amps set by Maximum Output control knob (Se[...]

  • Page 23

    B-6 OPERA TION B-6 • In 4-Step position allows welding without continu- ously holding the start switch trigger . The arc start switch functions in the following manner: 1. Closing switch starts preflow , then arc starts at Minimum (Start) setting level (See Item 7). If the trigger is maintained closed after preflow time the output remains at the [...]

  • Page 24

    B-7 OPERA TION B-7 INTERNAL SET UP CONTROLS Precision TIG 275 models which have an Advanced Panel (K1829-1) option installed* have the following additional control features which are set up using the DIP Switch (S1) provided on the internal panel of this option. Access to this internal panel is obtained by removing the two screws securing the top c[...]

  • Page 25

    B-8 OPERA TION B-8 PRECISION TIG 275 ( With DIP Switch #2 ON , As Shi pp ed ) ( With DIP Switch #2 OFF ) FIGURE B.3[...]

  • Page 26

    B-9 OPERA TION B-9 PRECISION TIG 275 FIGURE B.4 ( With DIP Switch #3 OFF , As Shi pp ed ) ( With DIP Switch #3 ON )[...]

  • Page 27

    B-10 OPERA TION B-10 SETUP GUIDELINES FOR TIG WELDING WITH AN AMPTROL Both the Hand and Foot Amptrols work in a similar manner . They are meant to be used for remote current control for TIG welding using the machine ’ s 2-Step trigger mode (See Item 12). The Amptrol is capable of controlling the output of the Precision TIG over the range between [...]

  • Page 28

    B-11 OPERA TION B-11 PRECISION TIG 275 Max. to Min. Amptrol Min. to Max. Amptrol Setup for TIG Ampt rol Weld ing Advanced P anel (If used) Standard C ontrols Power Switch ON Polarity Switch AC or DC - Mode Switch TIG AC Balance AUTO or Set: More + for a lum.oxid e " Cleaning " w/o "S pitti ng " o r " wettin g " loss. B[...]

  • Page 29

    B-12 OPERA TION B-12 PRECISION TIG 275 RECOMMENDED ELECTRODE AMPERAGE RANGES - PRECISION TIG 275 SMA W Process ELECTRODE POLARITY 3/32" 1/8" 5/32" Fleetweld 5P , Fleetweld 5P+ DC+ 40 - 70 75 - 130 90 - 175 Fleetweld 180 DC+ 40 - 80 55 - 1 10 105 - 135 Fleetweld 37 DC+ 70 - 95 100 - 135 145 - 180 Fleetweld 47 DC- 75 - 95 100 - 145 135[...]

  • Page 30

    C-1 ACCESSORIES C-1 OPTIONAL EQUIPMENT F ACT OR Y INST ALLED OPTIONS The basic Precision TIG 275 machine is factory equipped with: • A 3/8" Adapter (S20403-4) for air cooled torch con- nection of a PT A-9 or PT A-17. FIELD INST ALLED OPTIONS The following Options/Accessories are available for the Precision TIG 275 and are installed per instr[...]

  • Page 31

    D-1 MAINTENANCE D-1 PRECISION TIG 275 ELECTRIC SHOCK can kill. • Only qualified personnel should perform this maintenance. • T urn the input power OFF at the disconnect switch or fuse box before working on this equipment. • Do not touch electrically hot parts. T o avoid receiving a high frequency shock, keep the TIG torch and cables in good c[...]

  • Page 32

    D-2 MAINTENANCE D-2 SERVICE PROCEDURES Operation of the Precision TIG should be trouble-free for the life of the machine. Should a malfunction occur , however , the following procedures will be useful to trained service personnel with experience in repairing arc welding equipment: COMPONENT ACCESS The following components are accessible for routine[...]

  • Page 33

    DO NOT use a volt-ohm meter to measure output voltages in TIG mode. The High Frequency Arc Starter voltage can damage the meter . CAUTION E-1 TROUBLESHOOTING E-1 PRECISION TIG 275 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facili[...]

  • Page 34

    E-2 TROUBLESHOOTING E-2 PRECISION TIG 275 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION OUTP[...]

  • Page 35

    E-3 TROUBLESHOOTING E-3 PRECISION TIG 275 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION METE[...]

  • Page 36

    E-4 TROUBLESHOOTING E-4 PRECISION TIG 275 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION HI-F[...]

  • Page 37

    E-5 TROUBLESHOOTING E-5 PRECISION TIG 275 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PRES[...]

  • Page 38

    E-6 TROUBLESHOOTING E-6 PRECISION TIG 275 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION STIC[...]

  • Page 39

    E-7 TROUBLESHOOTING E-7 PRECISION TIG 275 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION TIG [...]

  • Page 40

    F-1 WIRING DIAGRAM F-1 PRECISION TIG 275 NOTE: This diagram is for refer ence only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a r eplacement. Give the equipme[...]

  • Page 41

    F-2 DIMENSION PRINT F-2 PRECISION TIG 275 L11660 XB-UF ** LOCATION OF ( 4) O .28 4 BASE MOUNTING HOLES. 12.77 31.00 26.00 1.00 24.00 ** .28 3.47 20.50 * * 22.00 .30 .75 3.4 4 TORCH HOLSTER 2.11 TORCH BOX 11.00 2.98[...]

  • Page 42

    NOTES PRECISION TIG 275[...]

  • Page 43

    NOTES PRECISION TIG 275[...]

  • Page 44

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA E[...]

  • Page 45

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. l Keep your head out of fumes. l Use ventilation or exhaust to remove fumes from [...]

  • Page 46

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .lincolnelectric.com • World's Leader in W elding and Cutting Products •[...]