Go to page of
Similar user manuals
-
Convection Oven
Lincoln 3262-2
40 pages 2.57 mb -
Convection Oven
Lincoln 1117-000-A
36 pages 2.04 mb -
Convection Oven
Lincoln 1450
24 pages 0.55 mb -
Convection Oven
Lincoln 1132-08H-A
40 pages 1.26 mb -
Convection Oven
Lincoln 1421-000-E
24 pages 0.62 mb -
Convection Oven
Lincoln 3240-2
40 pages 2.57 mb -
Convection Oven
Lincoln 1161-080-A
40 pages 1.26 mb -
Convection Oven
Lincoln 1600-000-A
24 pages 1.28 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Lincoln 1117-000-A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lincoln 1117-000-A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Lincoln 1117-000-A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Lincoln 1117-000-A should contain:
- informations concerning technical data of Lincoln 1117-000-A
- name of the manufacturer and a year of construction of the Lincoln 1117-000-A item
- rules of operation, control and maintenance of the Lincoln 1117-000-A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lincoln 1117-000-A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lincoln 1117-000-A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lincoln service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lincoln 1117-000-A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Lincoln 1117-000-A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1100AdvSvc REV 1/5/07 SER VICE MA NUAL (DOMESTIC ) IMPING ER CONVEYOR O VENS IMPINGER II - ADV ANT AGE SERIES Lincoln Foo dservice Products, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone : (800) 374 -3004 U.S. Fax: (888 ) 790-8193 • Int’l Fax: (260) 436 -0735 Technical Servi ce Hot Line (800) 6 78-95 11 ww[...]
-
Page 2
Impinger II – Advantage Service Man ual - Dom estic 2 T A BLE OF CONTENTS TABLE OF CO NTENT S 2 SEQUENC E OF OPER ATIONS 4 SEQUENC E OF OPER ATIONS 5 SCHEMAT IC 1116-000-A , 1117-000- A 6 SCHEMAT IC 1130-000-A / 1131-000- A 7 SCHEMAT IC 1132-000-A / 1133-000- A 8 TRO UBLESHOOTING G UIDE / GAS O VENS 9 TRO UBLESHOOTING G UIDE / ELECT RIC OVENS 14 [...]
-
Page 3
Impinger II – Advantage S ervice Man ual - Dom estic 3 SEQUENCE OF OPERA TIONS IMPING ER II ADV A NT A GE MODEL 11 16-000-A / NAT URAL GAS / 1 20 VAC / 6 0 HZ / 1 PHA SE MODEL 11 17-000-A / L. P. GAS / 120 V AC / 60 HZ / 1 PHASE POW ER SUPPLY Electrical po wer is suppli ed to the ove n by a three c onductor cords et. Voltage from the black conduc[...]
-
Page 4
Impinger II – Advantage Service Man ual - Dom estic 4 SEQUENCE OF OPERA TIONS 1130-000- A / 208V / SINGL E PHASE 1131-000- A / 240V / SINGL E PHASE 1132-000- A / 208V / TH REE PHASE 1133-000- A / 240V / TH REE PHASE POW ER SUPPLY Electrical po wer to be sup plied to the o ven by a thre e-conductor service on s ingle phase and a four-conduct or se[...]
-
Page 5
Impinger II – Advantage S ervice Man ual - Dom estic 5 SCHEMA TIC 1 1 16-000-A , 1 1 17 -000-A[...]
-
Page 6
Impinger II – Advantage Service Man ual - Dom estic 6 SCHEMA TIC 1 130-000-A / 1 131- 000-A[...]
-
Page 7
Impinger II – Advantage S ervice Man ual - Dom estic 7 SCHEMA TIC 1 132-000-A / 1 133- 000-A[...]
-
Page 8
Impinger II – Advantage Service Man ual - Dom estic 8 TROUBLESHOOTING GUIDE / GA S OVENS MODEL 11 16-000-A NATURAL G AS 120 VAC 60 HZ 1 PHASE MODEL 11 17-000-A LP GAS 120 VAC 60 HZ 1 PHASE SYMPTO M POSSIBLE CAUSE EVALUAT ION Oven fan wi ll not run Inc oming Power S uppl y Check breakers, r eset it required. Chec k power plug to be sure it is firm[...]
-
Page 9
Impinger II – Advantage S ervice Man ual - Dom estic 9 Burner Blo wer Motor Visuall y check to see if m otor is running. If not, check for 120 VAC to m otor at m otor connector ( wire #5 and #22). If voltage is n ot present, trac e wiring back to f an switch. If volta ge is present and m otor is not running, ch eck for opens, shorts , or grounds.[...]
-
Page 10
Impinger II – Advantage Service Man ual - Dom estic 10 Power Supp ly If there is suf ficient m icro-am p current, but the f lame will not sta y lit, check for proper polar ity of the 120 VAC power s uppl y . Ignition Contr ol If there is suff icient micro- amp current, an d the 120 VAC polari ty is correct, bu t the flam e will not sta y lit, rep[...]
-
Page 11
Impinger II – Advantage S ervice Man ual - Dom estic 11 Speed Adjus tment Potentiom eter This is a 0 to 10 K ohm , 1 turn potentiom eter. W ith power off , remove the blac k and white po t leads from the motor control boar d at term inals P1, P2. Place the m eter leads on t he black lead (P2) an d on the white lead ( P1). Rota ting the pot., sl o[...]
-
Page 12
Impinger II – Advantage Service Man ual - Dom estic 12 Tem p. display inoperat ive Display Tr ansformer Measure the transform er prim ary for a nominal 12 0 VAC input, if voltage is not present, tr ace wiring bac k to the oven power source. Measure the sec ondar y output, which will norm ally be 12-15 VA C. Voltage across term inals 1 and 3 o n t[...]
-
Page 13
Impinger II – Advantage S ervice Man ual - Dom estic 13 TROUBLESHOOTING GUIDE / ELEC TRIC OVENS MODEL 11 30-000-A 208 VAC SINGLE PHA SE 60 HZ MODEL 11 31-000-A 240 VAC SINGLE PHA SE 60 HZ MODEL 11 32-000-A 208 VAC THREE PH ASE 60 HZ MODEL 11 33-000-A 240 VAC THREE PH ASE 60 HZ REFER T O PROPER SC HEMAT IC FOR IDENT IFIED COMPON ENTS SYM PTOM POSS[...]
-
Page 14
Impinger II – Advantage Service Man ual - Dom estic 14 Tem perature Control Check for supply voltage at temper ature control. If no voltage is pr esent, trac e wiring b ack to hi-lim it therm ostat. Turn the tem perature adjus tment k nob to max imum temper ature position and c heck for 208/240 V AC at the load t erminals 7 and 8. If 208/240 V AC[...]
-
Page 15
Impinger II – Advantage S ervice Man ual - Dom estic 15 Speed Adjus tment Potentiom eter This is a 0 to 10 K ohm , 1 turn potentiom eter. W ith power off , remove the blac k and white po t leads from the motor control boar d at term inals P1, P2. Place the m eter leads on t he black lead (P2) an d on the white lead (P1). R otating the p ot., slow[...]
-
Page 16
Impinger II – Advantage Service Man ual - Dom estic 16 Hall Effec t Sensor Check for any physical da mage to hall effect s ensor (mounted on c onveyor dr ive m otor.) Check all wiring and con nections f or damage. chec k all connections f or dam age. Check all connections f or tightness or pr oper locat ion and check all wiring f or visible dam a[...]
-
Page 17
Impinger II – Advantage S ervice Man ual - Dom estic 17 REMOV A L, INST A LLA TION, A ND A DJUSTMENT IMPING ER II ADV A NT A GE CAUTION ! BEFORE R EMOVING OR I NSTALLING ANY COM PONENT IN THE IMPINGER OVEN, B E SURE T O DISCON NECT ELECTR ICAL POW ER AND GAS SU PPLY. MOTO R, MAIN F A N 1. Shut off power at m ain break er. 2. Remove m otor cover f[...]
-
Page 18
Impinger II – Advantage Service Man ual - Dom estic 18 FUSE HOL DER - REPL ACEMENT 1. Shut off power at m ain break er. 2. Remove contro l box cover and f ront panel. 3. Remove wires f rom fuse holder a nd mark for reass embly. 4. Remove m ounting screws or mounting nut on fuse hol der. Push fus e holder out. 5. Reassem ble in reverse ord er. THE[...]
-
Page 19
Impinger II – Advantage S ervice Man ual - Dom estic 19 BURNER T RANSFORM ER - REPL ACEMENT 1. Shut power off at main break er. 2. Remove contro l panel top and f ront cover. 3. Remove two (2) wires on pr imar y side, note co lor and loc ation. 4. Remove two (2) wires on secondar y side, note color a nd location. 5. Remove two (2) sc rews from tr[...]
-
Page 20
Impinger II – Advantage Service Man ual - Dom estic 20 ELECTRO NIC TEM PERA T URE CONTRO L BOARD - REPLACEM ENT 1. Remove contro l box cover. 2. Disconnect wires a nd mold ed connector a nd mark for reinstallation. 3. Depress n yl on clips and rem ove circuit board f rom m ounting brack et. 4. Reassem ble in reverse ord er and check operation. EL[...]
-
Page 21
Impinger II – Advantage S ervice Man ual - Dom estic 21 BYP ASS ORIFICE 1. Shut off power at m ain break er. 2. Shut off gas s upply to oven. 3. Remove contro l panel top and f ront cover. 4. Remove pilot tub e from bypass orifice and remove orifi ce. 5. Reassem ble in reverse ord er. TEM PERA TURE REGUL ATION VALVE - R EPL A CEM ENT 1. Shut off [...]
-
Page 22
Impinger II – Advantage Service Man ual - Dom estic 22 CONVEYOR CO NTROL BOARD - REPL ACEM ENT 1. Shut off power at m ain break er. 2. Remove contro l panel top and f ront cover. 3. Disconnect wiring ( push on connectors) f rom control b oard, note prop er location o f connectors for reinstallati on and exchang e boards o n the m ounting brack et[...]
-
Page 23
Impinger II – Advantage S ervice Man ual - Dom estic 23 HALL EFFE CT SENSOR - REPL A CEM ENT 1. Shut off power at m ain break er. 2. Remove contro l panel top and f ront cover. 3. Remove conve yor motor as sembly. 4. Remove wire co nnector fr om hall eff ect sensor board. 5. Remove two (2) sc rews from conveyor dr ive motor. 6. Remove sensor bo a[...]
-
Page 24
Impinger II – Advantage Service Man ual - Dom estic 24 HEATING ELEMENT - REPLACEMENT 1. Shut off power at m ain break er. 2. Remove back cover. 3. Disconnect heater element wires and m ark for reas sembl y . 4. Disconnect m otor wiring and m ark for reassembl y . 5. Remove oven bac k from oven. 6. Remove fan shr oud. 7. Heater elem ent may now b [...]
-
Page 25
Impinger II – Advantage S ervice Man ual - Dom estic 25 This page in tentionally left blank.[...]
-
Page 26
Impinger II – Advantage Service Man ual - Dom estic 26 P A RTS / GENERAL LETTER PART NUM BER DESCRIPT ION A 369390 Caster 4” w/ Mounting Pl ate B 369502 Bottom Finger Cover C Colum nating Panel, s ee Installation & Operations M anual D 370010 Bottom Finger Housing E 369504 Top Finger H ousing F Colum nating Pan el, see Instal lation & O[...]
-
Page 27
Impinger II – Advantage S ervice Man ual - Dom estic 27 BLOW UP / GENERAL[...]
-
Page 28
Impinger II – Advantage Service Man ual - Dom estic 28 P A RTS / CONTROL BOX 1 1 16-000-A , 1 1 1 7-000-A LETTER PART NUM BER DESCRIPT ION A 370108 Control Box Top B 369128 Pilot Light C 370073 Temperature Displ ay D 370107 Si de Pan el E 370131 Operations L abel F 369845 Knob G 3502 24 Lens, Yellow H 369805 On/Off Switch I 3698 09 Conveyor Poten[...]
-
Page 29
Impinger II – Advantage S ervice Man ual - Dom estic 29 BLOW UP / CONTROL BOX – 1 1 16-000-A , 1 1 17-000- A[...]
-
Page 30
Impinger II – Advantage Service Man ual - Dom estic 30 P A RTS / CONTROL BOX – 1 130-000-A THRU 1 133-000-A LETTER PART NUM BER DESCRIPT ION A 370108 Control Box Top B 369467 Pilot Light C 370073 Temperature Displ ay D 370107 Si de Pan el E 370132 Operations L abel F 369845 Knob G 350224 Lens, Yello w H 369432 On/Off Switch I 369809 Conve yor P[...]
-
Page 31
Impinger II – Advantage S ervice Man ual - Dom estic 31 BLOW UP / CONTROL BOX – 1 130-000-A THRU 1 133-000-A[...]
-
Page 32
Impinger II – Advantage Service Man ual - Dom estic 32 P A RTS / CONVEYOR & DOOR LETTER PART NUM BER DESCRIPT ION A 369611 Coupler B 369664 Coupling C enter C 369269 Bal l Plunger D 370116 Set Screw E 369223 Crum b Pan, Right F 3692 24 Crum b Pan, Left G 369666 Conve yor Frame Ass embly H 369226 Pan Stop J 369516 Conveyor Beari ng K 369514 Id[...]
-
Page 33
Impinger II – Advantage S ervice Man ual - Dom estic 33 BLOW UP / CONVEYOR & DOOR[...]
-
Page 34
Impinger II – Advantage Service Man ual - Dom estic 34 P A RTS / OVEN BACK A SSEMBL Y LETTER PART NUM BER DESCRIPT ION A 369182 Fan B 369899 Fan Shroud C 3696 55 Stand Off D 3691 83 Heating Elem ent 208V 369184 Heating E lement 240V E 369976 Rear W all, Gas Ovens 369549 Rear W all, Electric Ove ns F 369581 Motor Mou nt G 3695 39 Motor, Gas Ovens [...]
-
Page 35
Impinger II – Advantage S ervice Man ual - Dom estic 35 BLOW UP / OVEN BACK A SSEMBL Y[...]
-
Page 36
Impinger II – Advantage Service Man ual - Dom estic 36[...]