A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Linear AE-500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Linear AE-500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Linear AE-500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Linear AE-500 should contain:
- informations concerning technical data of Linear AE-500
- name of the manufacturer and a year of construction of the Linear AE-500 item
- rules of operation, control and maintenance of the Linear AE-500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Linear AE-500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Linear AE-500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Linear service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Linear AE-500.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Linear AE-500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    AE-500 T elephone Entr y & Access Control System PRINTER’S INSTRUCTIONS: INSTR,F ACILITY MANA GER,AE-500 - LINEAR P/N: 221000 E - INK: BLACK - MA TERIAL: 20 LB . MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALB UM-FOLD - BINDING: SADDLE-STITCH Facility Manager’s Guide USA & Canada (800) 421-1587 & (800) 392-0123 (7[...]

  • Page 2

    2 Contents Introduction The Model AE-500 T elephone Entry & Access Control System is designed for use as a primary access control device f or gated communities, parking garages, offi ce buildings, apartments, dor mitories, hotels/motels, commercial buildings and recreational f acilities with up to 250 residents or users. Housed in a lock ed, r[...]

  • Page 3

    3 Sys tem F eatur es DI S PLAY CABINET LOCK OPTIONAL PO S TAL LOCK S PEAKER KEYPAD LIGHTING KEYPAD MICROPHONE Your access control installation company has set this master password for this installation: _______________________ Use this password to enter programming mode.[...]

  • Page 4

    4 P r ogramming with a Computer The AE-500’ s built-in progr amming interface can be accessed on-site (using a separate telephone line) or off-site using a computer with a modem and any Internet browser (if using Netscape, be sure J ava is installed). The AE-500 can be progr ammed using the local keypad or with a telephone, b ut computer programm[...]

  • Page 5

    5 Set ting up Multiple Units The system suppor ts up to se ven AE-500s connected to the same telephone line. Some telephone systems ma y only suppor t up to four units on the same telephone line. In multiple-unit installations each AE-500 m ust be assigned a unique unit number bef ore programming. The unit number allows connecting to a specifi c u[...]

  • Page 6

    6 P r ogramming Over the T elephone The system can be programmed using a T ouchT one™ telephone. The telephone’ s ke ypad will act similar to the AE-500’ s local keypad. Connecting with a T elephone 1. Place a call to the telephone number of the line that AE-500 is connected to . 2. The AE-500 will answ er and sound a tone for about ½ second[...]

  • Page 7

    7 P r ogramming Refer ence PROGRAMMING CONTROL USAGE KEYSTROKES ENTER PROGRAMMING FROM LOCAL KEYP AD . . . . . . . . Press 0 and 2 then MASTER P ASSWORD ENTER PROGRAMMING FROM TELEPHONE . . . .Call, wait for tone then enter MASTER PASSWORD ESCAPE/CANCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 8

    8 Resident Data P r ogramming Up to 250 resident names and telephone numbers can be set. Each resident entry is assigned a director y number . The director y numbers are the numbers visitors enter to hav e the system call the residents. ✦ NO TE: When entering resident names, programming the AE-500 from a computer is the pref erred method. Ref er [...]

  • Page 9

    9 Entr y Code Programming Changing the Entr y Code Length The factory setting for the entry code length is 4 digits. It can be set to 2-6 digits. 1. If not already in Programming Mode, connect b y telephone or use the local ke ypad. Enter the master password and access prog ramming. 2. Press 3 . Enter the entry code length (2, 3 , 4, 5, or 6). 4. P[...]

  • Page 10

    10 Wir eless T ransmit ter Pr ogramming Up to 500 wireless transmitters can be used with the system. T ransmitters can be ordered in pre-programmed b locks of sequential ID codes. Up to 16 blocks of transmitters can be used. T ransmitter bloc ks can be ordered with a F acility Code of 1-15 for b lock identifi cation if desired. Using Facility Code[...]

  • Page 11

    11 Wir eless T ransmit ter Pr ogramming (Continued) Activate a T ransmitter If a transmitter has been suspended, it can be activated again with these programming steps. 1. If not already in Programming Mode, connect b y telephone or use the local ke ypad. Enter the master password and access prog ramming. 2. Press 3 . Enter the transmitter’ s f a[...]

  • Page 12

    12 Sys tem Options For most installations the f actory settings for the system will be appropriate. Y our installer may ha ve already customized some of the system settings . T o change selected system settings, use the f ollowing programming steps . Keypad Lock out Count The system counts the number of inv alid entry codes are entered at the local[...]

  • Page 13

    13 Sys tem Options (Continued) Speaker T one on Relay Channel “A” Activation The factory setting will not cause the speaker to sound a tone when access is granted with Rela y Channel “A”. The tone can be turned on if desired. 1. If not already in Programming Mode, connect b y telephone or use the local ke ypad. Enter the master password and[...]

  • Page 14

    14 Sys tem Utilities Sev eral utility commands are av ailable f or the system. Utilities can be used to clear memory , display system information, and control the relays . Display Unit Number In multi-unit installations the unit number of each AE-500 can be displa yed. 1. If not already in Programming Mode, use the local k eypad to enter the master[...]

  • Page 15

    15 AE-500 Operation Requesting Access with an Entr y Code • Residents hav e up to 40 seconds to ke y in their entr y code. • Up to eight seconds are allowed betw een each keystrok e. • All digits of the entr y code must be entered. Example: If the entr y code length is set for f our digits, and the code is 0042, the user must enter “0 0 4 2[...]

  • Page 16

    Copyright © 2008 Linear LLC 221000 E T r oubleshooting System completely dead 1. Call installation company f or ser vice. Buzz on speaker 1. Call installation company f or ser vice. Buzz on telephone line 1. Call installation company f or ser vice. System will not answer an incoming call 1. AE-500 telephone line trouble . 2. Call installation comp[...]