Go to page of
Similar user manuals
-
Stereo Amplifier
Linn Klout
20 pages 0.08 mb -
Stereo Amplifier
Linn C 2200
26 pages 0.5 mb -
Stereo Amplifier
Linn 2200
22 pages 0.57 mb -
Stereo Amplifier
Linn WAKONDA
24 pages 0.24 mb -
Stereo Amplifier
Linn AKURATE 2200
22 pages 0.6 mb -
Stereo Amplifier
Linn 2250
10 pages 0.18 mb -
Stereo Amplifier
Linn Kolektor
48 pages 0.35 mb -
Stereo Amplifier
Linn LK140
24 pages 0.38 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Linn Twin Klimax, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Linn Twin Klimax one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Linn Twin Klimax. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Linn Twin Klimax should contain:
- informations concerning technical data of Linn Twin Klimax
- name of the manufacturer and a year of construction of the Linn Twin Klimax item
- rules of operation, control and maintenance of the Linn Twin Klimax item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Linn Twin Klimax alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Linn Twin Klimax, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Linn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Linn Twin Klimax.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Linn Twin Klimax item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Linn T win Klimax Dual Speaker P ower Amplifier[...]
-
Page 2
Impor tant safety informa tion Explanation of symbols used in this manual and on the product. This symbol is intended to alert the user to the presence of insulated dangerous v oltages within the enclosure of sufficient magnitude to cause electric shock. This symbol is intended to alert the user to the presence of important maintenance and servicin[...]
-
Page 3
Input impedance: Single ended 7K8ohms Balanced 7K8ohms Input lev el for clipping: Balanced 2v rms Unalanced 4v rms Single ended 1.67 Vrms Signal sensing threshold >150uV Output connectors: Standard Neutrik Optional Binding posts Output pow er 230W rms into 4ohms 100W rms into 8ohms Load toleranc e Unconditionally stable into all loudspeaker load[...]
-
Page 4
UK Users please r ead this impor tant safety informa tion F use replacement This appliance is fitted with a non-rewir eable 13 Amp mains plug. The plug contains a 5 Amp fuse. If the fuse has blown it can be replaced as follo ws: a) Pull out the red fuse co ver/carrier . b) Remove and dispose of the blown fuse . c) Fit a new 5 Amp BS1362 appr oved f[...]
-
Page 5
CE Declara tion of C onformity Linn Products Ltd . declares that this product is in conformance with the Low V oltage Direc tive 73/23/EEC and Electromagnetic Compatibility 89/336/EEC as amended by 92/31/EEC and 93/68/EEC. The conformity of the designated pr oduct with the provisions of Directive numbers 73/23/EEC (L VD) is proved by full complianc[...]
-
Page 6
C opyrigh t and acknowledgements Copyright @ Linn P roducts Limited. Linn Products LImited , Floors Road , Waterfoot, Glasgow , G76 0EP , Scotland, United Kingdom. All rights reserved. No part of this publication may be reproduced , stored in a retrieval syst em, or transmitted , in any form or b y any means , electronic, mechanical, photocopying ,[...]
-
Page 7
C onten ts 1. Introduction 2 2. What is it? 3 3. How does the Klimax work? 4 What is switch mode? 5 So what’ s the problem? 6 Some assorted fac ts 7 Inside the Klimax 8 The audio circuitry 9 Output current and protection 11 4. Installation 13 Heat 13 Mains supply 15 Signal sensing 17 Inputs and Outputs 18 5. Operation 19 6. Specifications 20 7. G[...]
-
Page 8
1. Introduction Thank you f or buying the Klimax Twin, the second member of the Klimax amplifier family and the best amplifiers we make. Lik e the Klimax Solo the K limax Twin uses the latest t echnology and exemplifies our constant endeav our to make ever better sounding pr oducts. W e are confident that the compact, elegant design and the excepti[...]
-
Page 9
2. Wha t is it? The Klimax Twin is a tw o channel power amplifier designed f or use in multi amplifier and multi channel audio and audio/video systems. The case is precision machined from two solid sections of aluminium alloy . The machining is done on a computer contr olled multi-axis machining centre , with the final cut on the top face made by a[...]
-
Page 10
3. How does the Klimax w ork? In most power amplifiers the pow er supply comprises a large tr ansformer , a rectifier and reser voir capacitors, of ten as large as the transformer . The highest per formance amplifiers also have v oltage regulators which maintain the pow er supplied to the amplifier circuitry constant, regardless of the input voltag[...]
-
Page 11
What is switch mode? In a switch mode power supply the inc oming mains is filtered then rectified to generat e a very high voltage dc (direct current) supply . This is usually about 300 to 350 Volts dc , which is far too high to operate audio circuitry direc tly , and is still connec ted directly to the incoming mains supply . Such a high voltage i[...]
-
Page 12
So what’ s the problem? The first problem is that this is a lot more c omplicated than a mains transformer (a f ew k ilos of copper and iron), a rectifier and some large capacitors. A switch mode design optimised for minimum part count will still have man y tens of par ts, most of which are quite delicate but still have t o operate reliably in a [...]
-
Page 13
Some assor ted facts The transf ormer in the Klimax is less than 40mm (1.5 inches) cube. At 50/60 Hz it could deliver about 5 W atts. In the K limax it can deliver 1000 Watts . The reservoir capacitors in the Klimax are about the size of a thimble but give bett er filtering than ones the size of a beer can used in other very powerful amplifiers. Th[...]
-
Page 14
Inside the Klimax 8[...]
-
Page 15
The audio cir cuitry At Linn because we striv e for continuous impr ovement in ev er ything we do we use appropriat e technologies to achieve our goals . There have been man y fine amplifier designs over the history of audio. Some use valv es (tubes), some use bipolar transistors, some MOSFET s. Some manufacturers swear by Class A, others by Class [...]
-
Page 16
T o achieve the performance and power output w e use three chips per channel, and like the Klimax Solo the Klimax T win is direct coupled with no capacitors in the signal path. Combined with a slightly modified Klimax Solo power supply we ha ve achiev ed , as we know you will hear , true audiophile per formance. 10[...]
-
Page 17
Output current and pr otection A commonly asked question about a power amplifier conc erns its maximum output current. There is some good reason behind this question. There is always some trade off betw een output power , 'specmanship', protection and cost in a power amplifier . Output power specification (into 8 Ohms) can be incr eased s[...]
-
Page 18
The Klimax Twin, lik e all Linn amplifiers, is specified into a 4 Ohm load. We don't do this t o claim a bigger output power , but to show that our amplifiers are int ended and fully specified for operation into 4 Ohm loudspeakers. Most Linn loudspeakers have nominally 4 Ohms input impedance. The Klimax Twin has a simple decision making protec[...]
-
Page 19
4. Installation The compactness of the Klimax T win makes it ver y easy to install and makes possible high power multi- amplifier systems which would be impractical with con ventionally designed amplifiers of similar pow er , because of their size and weight. The unique wall mount system can be used to minimise the intrusion of the audio system int[...]
-
Page 20
When operating , the fan draws cool air in through the back of the amplifier , and blows it along the heat exchanger until it exits through the fr ont, top and bottom. The amplifier is fully protected against ov er heating , but this is only for protection and should never operate in normal use, whatever your 'normal use' is. If you only [...]
-
Page 21
Mains supply The Klimax Twin has an aut omatic internal mains voltage swit ch. This allows it to operate from 90 V ac to 260 V ac. With a mains supply below 140 V ac two seconds after switching on the amplifier the power supply switches to low range , with a just audible click, and remains there as long as power is applied . F or all normal music o[...]
-
Page 22
F itting in separate mains wiring spurs for the sour ces and pow er amplifiers is not to isolate them from the mains distortion present in the rest of the house; it's to reduce ho w much of the mains distortion from the power amplifiers gets into the other audio c omponents in the system! Linn switch mode pow ered components can actually help [...]
-
Page 23
Signal sensing In the absence of a music input signal the Klimax Twin r everts to a low power standb y mode after 10 minutes. The signal detector is very sensitive and waits about one second before po wering up the amplifier to be certain the signal is real, not just noise. The detection threshold has been found ov er many installations to be a goo[...]
-
Page 24
Inputs and outputs The Klimax Twin has both unbalanc ed and balanced inputs, selec ted by a switch on the back panel. Use the appropriate one to suit y our choice of preamplifier and cabling . The LED will indicate when the unbalanced inputs are selected. Both signals are echoed out the unbalanced 'line out' socket to enable daisy chainin[...]
-
Page 25
5. Opera tion This is the easiest bit. The blue light will be dim when power is first applied , then remain dimmed with the Klimax T win in standby mode. When a signal is detected the light brightens up as the amplifier is enabled. If the amplifier needs to protect itself it will shut down entirely f or a few seconds and dim the light. There is no [...]
-
Page 26
6. Specifications General Dimensions V350mm W x 355mm L x 60mm H. 13.8"w x 13.9"L x 2.3"H W eight 9Kg/19.84 lbs Protection F use rating T6.3A Mains input range 90V ac - 126V Ac 200V Ac - 253V Ac @50/60Hz Maximum input power 1000W typical operating input power 39W Standby power 18W Amplifier specification Input connectors: Unbalanced [...]
-
Page 27
Input impedance: Single ended 7K8ohms Balanced 7K8ohms Input lev el for clipping: Balanced 2v rms Unalanced 4v rms Single ended 1.67 Vrms Signal sensing threshold >150uV Output connectors: Standard Neutrik Optional Binding posts Output pow er 230W rms into 4ohms 100W rms into 8ohms Load toleranc e Unconditionally stable into all loudspeaker load[...]
-
Page 28
7. Guarantee and service This product is guaranteed under the conditions which apply in the country of purchase and your statutory rights are not limited . T o help us, please ask your retailer about the Linn warranty scheme in operation in your country . In parts of Europe, America and some other markets, extended warranty may be offered to custom[...]
-
Page 29
Refer to the Linn W eb Site for news , product listings and prices, system building guidelines and information on the type of outlets near you who can supply local warranty , terms of trading, price and sales tax information, or call a Linn helpline for the information y ou need . Our address is: LINN Products Limited Floors Road Glasgow , Scotland[...]
-
Page 30
8. Index A Acknowledgements v Assorted fac ts 7 Audio circuitry 9 C Copyright v Current limiting 12 D Dimensions 20 F F use replacement iii G Gain 20 General description 3 General safety instructions ii Guarantee 22 H Heat 13 How the Klimax works 4 I Input connectors 20 Input impedance 20 Input level for clipping 21 Inputs 18 Inside the Klimax 8 In[...]