LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC should contain:
- informations concerning technical data of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC
- name of the manufacturer and a year of construction of the LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC item
- rules of operation, control and maintenance of the LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the LSI service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® DB15-000264-02 2 Gbit/s Fibre Channel Host Adapters LSI7102XP-LC , LSI7102LXP-LC LSI7202XP-LC , LSI7202LXP-LC LSI7402XP-LC LSI7202EP-LC , LSI7202EP LSI7402EP-LC , LSI7402EP USER’S GUIDE A ugust 2005 V ersion 2.1[...]

  • Page 2

    ii Copyright © 2002, 2005 by LSI Logic Corporation. All rights reserved. This document contains proprietar y inf or mation of LSI Logic Cor poration. The inf or mation contained herein is not to be used by or disclosed to third parties without the e xpress wr itten permission of an officer of LSI Logic Cor poration. LSI Logic products are not int[...]

  • Page 3

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide iii Copyright © 2002, 2005 by LSI Logic Corporation. All rights reserved. Preface This book is the primar y reference and user’ s guide for the LSI Logic f amily of 2 Gbit/s Fibre Channel host adapter boards. It contains a complete functional description of these boards as well as complete ph [...]

  • Page 4

    iv Pref ace Copyright © 2002, 2005 by LSI Logic Corporation. All rights reserved. Related Publications LSIFC929X Dual Channel Fibre Channel I/O Processor T echnical Manual, Document No . DB14-000202-01 LSIFC919X Single Channel Fibre Channel I/O Processor T echnical Manual, Document No . DB15-000225-01 Fusion-MPT™ De vice Management User’ s Gui[...]

  • Page 5

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide v Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Contents Chapter 1 Installation Procedures 1.1 General Description 1-1 1.2 Quick Installation Procedure 1-2 1.3 Detailed Installation Procedure 1-3 1.3.1 Bef ore Y ou Star t 1-3 1.3.2 Installing the Host Adapter 1-3 Chapter[...]

  • Page 6

    vi Contents Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8 Ph ysical Characteristics 2-9 2.8.1 LSI7102XP-LC Host Adapter Configuration 2-9 2.8.2 LSI7102XP-LC Connector and Indicator LED 2-10 2.8.3 LSI7102LXP-LC Host Adapter Configuration 2-12 2.8.4 LSI7102LXP-LC Connector and Indicator LED 2-13 2.8.5 LSI7202XP-LC Host[...]

  • Page 7

    Contents vii Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Chapter 4 BIOS Features 4.1 LSI Logic Boot BIOS 4-2 4.1.1 LSI Logic Boot BIOS Features 4-2 4.1.2 BIOS Overview 4-2 4.1.3 LSI Logic BIOS Boot Specification (BBS) 4-2 4.2 Star ting the LSI Logic Boot BIOS Configuration Utility 4-3 4.3 Using the LSI Logic Boot BIOS [...]

  • Page 8

    viii Contents Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.[...]

  • Page 9

    ix Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Figures 1.1 Hardware Connections f or the LSI Logic Host Adapter 1-4 1.2 Inser ting the LSI Logic Host Adapter 1-5 2.1 LSI7102XP-LC Host Adapter Configuration 2-10 2.2 LSI7102XP-LC Connector and Indicator LED 2-11 2.3 LSI7102LXP-LC Host Adapter Configuration 2-12 2.4 LSI71[...]

  • Page 10

    x Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.[...]

  • Page 11

    xi Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. T ables 2.1 LSI Logic 2 Gbit/s FC Host Adapter Descr iptions 2-2 2.2 Hardware and Softw are Requirements 2-3 2.3 Maximum P ower Requirements 2-5 2.4 LED Appearance to Represent Link Status 2-7 2.5 PCI System ID V alues 2-8 2.6 PCI Subsystem ID V alues 2-8 2.7 LSI7102XP-LC Li[...]

  • Page 12

    xii Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.[...]

  • Page 13

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide 1-1 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Chapter 1 Installation Pr ocedures This chapter contains general inf or mation about the LSI Logic 2 Gbit/s f amily of Fibre Channel (FC) host adapters. It also provides host adapter installation instructions. This chapte[...]

  • Page 14

    1-2 Installation Procedures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 1.2 Quic k Installation Procedure This section provides an o verview of the installation procedure. If y ou are an e xper ienced computer user with prior host adapter installation and FC setup e xper ience , this section may describe the procedure su[...]

  • Page 15

    Detailed Installation Procedure 1-3 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 1.3 Detailed Installation Pr ocedure This section provides step-b y-step instructions for installing the host adapter . If you are e xper ienced in these tasks , you ma y prefer to use Section 1.2, “Quick Installation Procedure. ” 1.3.1 B[...]

  • Page 16

    1-4 Installation Procedures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. connector contacts. LSI Logic recommends using a static ground strap . Step 5. Locate the slots for PCI plug-in board installation. Ref er to the user’ s manual supplied with your computer to confirm the location of the PCI slots. This host adapte[...]

  • Page 17

    Detailed Installation Procedure 1-5 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Step 7. Carefully inser t PCI Bus edge connector J1 (see Figure 1.1 )o f the host adapter into the PCI slot. Make sure the edge connector is properly aligned bef ore pressing the board into place, as sho wn in Figure 1.2 . The brac ket around[...]

  • Page 18

    1-6 Installation Procedures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.[...]

  • Page 19

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide 2-1 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Chapter 2 2 Gbit/s FC Host Adapter Characteristics This chapter provides specific details about the ph ysical environment associated with the 2 Gbit/s f amily of FC host adapters. This chapter includes the f ollowing sec[...]

  • Page 20

    2-2 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. This manual serves as a step-by-step guide during the installation of y our LSI Logic host adapter . T able 2.1 lists the 2 Gbit/s FC host adapters discussed in this User’ s Guide. Hard ware and Software Suppor t – The LSI Logic [...]

  • Page 21

    F eatures 2-3 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.2 Features This section provides an o verview of the PCI-X Interf ace , the PCI Express Interf ace , and the FC Interface for the 2 Gbit/s f amily of host adapters. 2.2.1 PCI-X Interface PCI-X interf aces I/O components to the processor and memor y subsystems in[...]

  • Page 22

    2-4 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.2.2 PCI Express Interface The PCI Express (launched in 2002) interf ace is a new serial I/O interf ace standard being used in next gener ation computer , storage and communications platf or ms . This scalable interf ace allows v en[...]

  • Page 23

    Ph ysical Environment 2-5 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.3.1 Electrical Characteristics T able 2.3 lists the maximum power requirements and includes all of the LSI Logic 2 Gbit/s FC host adapter boards under nor mal oper ation. 2.3.2 Thermal, Atmospheric Characteristics The thermal, atmospher ic characteri[...]

  • Page 24

    2-6 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.3.3 Electroma gnetic Compliance These boards are designed and implemented to minimize susceptibility to electromagnetic emissions, and the eff ects of electromagnetic discharge. The boards are tested to comply with Class B and carr[...]

  • Page 25

    PCI System ID V alues 2-7 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.4.3 FC Interface The FC interf ace varies, depending on which LSI Logic 2 Gbit/s host adapter you ha ve selected. Ref er to Section 2.8, “Ph ysical Characteristics, ” page 2-9 f or details. 2.4.4 FC Link Activity/Link Fault LED The LSI Logic 2 Gb[...]

  • Page 26

    2-8 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.6 PCI Subsystem ID V alues All LSI Logic 2 Gbit/s host adapters are assigned PCI Subsystem V endor IDs (SVIDs) and Subsystem IDs (SSIDs) to allow drivers and BIOS to diff erentiate the individual host adapter variants. The SVID and[...]

  • Page 27

    Unique W or ld Wide Name 2-9 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.7 Unique W orld Wide Name Each LSI Logic FC host adapter is provided with a unique W orld Wide Name, specified b y IEEE. The last 12 hexadecimal char acters of this address appear on a host adapter label. This address is stored in the host adapte[...]

  • Page 28

    2-10 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Figure 2.1 LSI7102XP-LC Host Adapter Configuration 2.8.2 LSI7102XP-LC Connector and Indicator LED The LSI7102XP-LC I/O brac ket is configured as shown in Figure 2.2 . The LC connector provides the connection from the adapter chann[...]

  • Page 29

    Ph ysical Characteristics 2-11 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Figure 2.2 LSI7102XP-LC Connector and Indicator LED T able 2.7 descr ibes the LSI7102XP-LC Link Activity/Link F ault LED appearance that indicates a v alid link, presence of link activity , or a fault on the link. T able 2.7 LSI7102XP-LC Link Acti[...]

  • Page 30

    2-12 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.3 LSI7102LXP-LC Host Adapter Configuration The LSI Logic LSI7102LXP-LC is a single channel 2 Gbit/s FC adapter . One LC optical connector is used f or I/O , which is accessible through the module brac ket. The LSI7102LXP-LC hos[...]

  • Page 31

    Ph ysical Characteristics 2-13 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.4 LSI7102LXP-LC Connector and Indicator LED The LSI7102LXP-LC I/O brac ket is configured as shown in Figure 2.4 . The LC connector provides the connection from the adapter channel to the FC subsystem. The indicator LED indicates link status, a[...]

  • Page 32

    2-14 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.5 LSI7202XP-LC Host Adapter Configuration The LSI Logic LSI7202XP-LC is a dual-channel, 2 Gbit/s FC adapter . T wo LC optical connectors, used f or I/O, are accessib le through the module brac ket. The LSI7202XP-LC uses the LSI[...]

  • Page 33

    Ph ysical Characteristics 2-15 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.6 LSI7202XP-LC Connectors and Indicator LEDs The LSI7202XP-LC I/O brac ket is configured as sho wn in Figure 2.6 . The LC connectors provide the connections from the adapter channels to the FC subsystem. The indicator LEDs indicate link status[...]

  • Page 34

    2-16 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.7 LSI7202LXP-LC Host Adapter Configuration The LSI Logic LSI7202LXP-LC is a dual-channel, 2 Gbit/s FC adapter . T wo LC optical connectors, used f or I/O, are accessib le through the module brac ket. The LSI7202LXP-LC uses the [...]

  • Page 35

    Ph ysical Characteristics 2-17 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.8 LSI7202LXP-LC Connectors and Indicator LEDs The LSI7202LXP-LC I/O brac ket is configured as shown in Figure 2.8 . The LC connectors provide the connections from the adapter channels to the FC subsystem. The indicator LEDs indicate link statu[...]

  • Page 36

    2-18 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.9 LSI7202EP-LC Host Adapter Configuration The LSI Logic LSI7202EP-LC is a dual-channel, 2 Gbit/s FC adapter . T wo LC optical connectors, used f or I/O, are accessib le through the module brac ket. The LSI7202EP-LC uses the LSI[...]

  • Page 37

    Ph ysical Characteristics 2-19 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.10 LSI7202EP-LC Connectors and Indicator LEDs The LSI7202EP-LC I/O brac ket is configured as sho wn in Figure 2.10 . The P or t 0 and P or t 1 connectors provide the connections from the adapter channels to the FC subsystem. The indicator LEDs[...]

  • Page 38

    2-20 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.11 LSI7202EP Host Adapter Configuration The LSI Logic LSI7202EP is a dual-channel, 2 Gbit/s FC adapter . T wo connectors, used f or I/O, are accessib le through the module brac ket. The LSI7202EP uses the LSIFC929X, providing t[...]

  • Page 39

    Ph ysical Characteristics 2-21 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.12 LSI7202EP Connectors and Indicator LEDs The LSI7202EP I/O brac ket is configured as sho wn in Figure 2.12 . The P or t 0 and P or t 1 connectors provide the connections from the adapter channels to the FC subsystem. The indicator LEDs indic[...]

  • Page 40

    2-22 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.13 LSI7402XP-LC Host Adapter Configuration The LSI Logic LSI7402XP-LC is a quad-channel, 2 Gbit/s FC adapter . F our LC optical connectors, used f or I/O , are accessible through the module brac ket. The LSI7402XP-LC uses two L[...]

  • Page 41

    Ph ysical Characteristics 2-23 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.14 LSI7402XP-LC Connectors and Indicator LEDs The LSI7402XP-LC I/O brac ket is configured as sho wn in Figure 2.14 . The LC connector provides the connection from the adapter channel to the FC subsystem. The indicator LEDs indicate link status[...]

  • Page 42

    2-24 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.15 LSI7402EP-LC Host Adapter Configuration The LSI Logic LSI7402EP-LC is a quad-channel, 2 Gbit/s FC adapter . F our LC optical connectors, used f or I/O , are accessible through the module brac ket. The LSI7402EP-LC uses two L[...]

  • Page 43

    Ph ysical Characteristics 2-25 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.16 LSI7402EP-LC Connectors and Indicator LEDs The LSI7402EP-LC I/O brac ket is configured as sho wn in Figure 2.16 . The LC connectors provide the connections from the adapter channels to the FC subsystem. The indicator LEDs indicate link stat[...]

  • Page 44

    2-26 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.17 LSI7402EP Host Adapter Configuration The LSI Logic LSI7402EP is a quad-channel, 2 Gbit/s FC adapter . F our connectors, used f or I/O, are accessib le through the module brac ket. The LSI7402EP uses two LSIFC929X de vices, p[...]

  • Page 45

    Ph ysical Characteristics 2-27 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 2.8.18 LSI7402EP Connectors and Indicator LEDs The LSI7402EP I/O brac ket is configured as sho wn in Figure 2.18 . The P or t 0, P or t 1, P or t 2, and P or t 3 connectors provide the connections from the adapter channels to the FC subsystem. The[...]

  • Page 46

    2-28 2 Gbit/s FC Host Adapter Characteristics Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.[...]

  • Page 47

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide 3-1 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Chapter 3 Firmware Installation Pr ocedure This chapter provides inf or mation about installing and configur ing FC firmware and includes the follo wing sections: • Section 3.1, “FC Fir mware” • Section 3.2, “[...]

  • Page 48

    3-2 Firmware Installation Procedure Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 3.1 FC Firmware This section includes the f eatures, description, installation, and configuration of the FC firmware. The installation method v aries depending on the operating system. LSI Logic provides fir mware installation tools f or t[...]

  • Page 49

    Download Ne w FC Fir mware 3-3 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. frames to the controller , and processing reply message frames received from the controller . The LSI Logic firmware translates Fusion-MPT message frames into FC-specific sequences, frames , and primitives that are deliv ered to the FC transmit an[...]

  • Page 50

    3-4 Firmware Installation Procedure Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. These files represent updated code that you ma y store on your LSI Logic host adapter using one of the methods described in the next sections. 3.3 Update the FC Firmware The process of updating the FC fir mw are varies slightly , depending [...]

  • Page 51

    Update the FC Firmware 3-5 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Step 2. Open a ter minal window , and open the director y containing the LSIUtil program. Step 3. Ex ecute the LSIUtil program. Step 4. Select a device to update ( Figure 3.1 ). Figure 3.1 LSIUtil Device Selection Step 5. F rom the subsequent displa y[...]

  • Page 52

    3-6 Firmware Installation Procedure Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Figure 3.2 LSIUtil Download Options Step 6. When prompted, type the fir mware file name . Step 7. T ype Y es , when asked to continue ( Figure 3.3 ). Figure 3.3 LSIUtil File Download The update process requires about 20–30 seconds. Upon c[...]

  • Page 53

    Update the FC Firmware 3-7 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 3.3.3 Command Line Update T ool for DOS Using a DOS bootable flopp y , users can use a FC Flash Utility called MPTUtil to update LSI Logic adapters with new firmware ( Section 3.2, “Download Ne w FC Fir mw are, ” page 3-3 ) . This section provid[...]

  • Page 54

    3-8 Firmware Installation Procedure Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Step 5. The MPTUtil program displa ys a menu of options ( Figure 3.5 ). T o update the fir mw are, select option a - Update Firmware . Figure 3.5 MPTUtil Options Step 6. When prompted, type the filename of the BIOS/Fcode update. The update [...]

  • Page 55

    Advanced User: Adjusting Default Firmware Settings 3-9 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. LSI Logic Adapter , and should be reser ved f or adv anced users who fully understand the implications of such changes. The LSI Logic fir mw are suppor ts sev eral configuration options , defined individually in Section [...]

  • Page 56

    3-10 Firmware Installation Procedure Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. g - T oggle Board Speed on Function 1 Successively pressing the F k ey (f or Function 0) or the G key (f or Function 1) toggles the PORT speed setting betw een these three modes: • AU TO • 1 Gbit/s • 2 Gbit/s Step 3. Exit the FCUtil ut[...]

  • Page 57

    Advanced User: Adjusting Default Firmware Settings 3-11 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. A: Mptutil The MPTUtil program identifies all LSI Logic host adapters in the system, and allows y ou to select which adapter to update. (See Figure 3.4 .) Step 2. The MPTUtil program displa ys a menu of options. (See Fig[...]

  • Page 58

    3-12 Firmware Installation Procedure Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 3.5 T roub leshooting Some potential problems and their suggested solutions are as f ollows: The firmware and BIOS revisions typicall y must be in sync for proper operation. Check with LSI Logic T echnical Suppor t to make sure that the Fir[...]

  • Page 59

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide 4-1 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Chapter 4 BIOS Features This chapter describes the Fibre Channel (FC) BIOS and Configuration Utility and includes the following sections: • Section 4.1, “LSI Logic Boot BIOS” • Section 4.2, “Star ting the LSI L[...]

  • Page 60

    4-2 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.1 LSI Logic Boot BIOS This section provides the f eatures, description, and installation of the LSI Logic FC boot BIOS. 4.1.1 LSI Logic Boot BIOS Features The LSI Logic FC boot BIOS suppor ts: • Selection and configuration f or up to 256 adapters • Boo[...]

  • Page 61

    Star ting the LSI Logic Boot BIOS Configuration Utility 4-3 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.2 Star ting the LSI Logic Boot BIOS Configuration Utility The LSI Logic boot BIOS allows y ou to change the default configuration of your host adapters , using the embedded BIOS Configuration Utility (CU). When t[...]

  • Page 62

    4-4 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. ENTER, the FC Link bus is scanned and the Adapter Properties screen appears. On the Main menu, two selections are the Boot Adapter List and Global Proper ties menus. Boot Adapter List allows selection and ordering of boot adapters. Ref er to Section 4.4.4, ?[...]

  • Page 63

    Main Menu 4-5 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. current page bef ore new entries may be vie wed or modified. A pop-up confirmation window asks to store or discard changes, if needed. 4.4.3 Device Pr operties Menu The De vice Proper ties menu allows y ou to view and update individual de vice settings for an ad[...]

  • Page 64

    4-6 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.4.5 Global Properties Menu The Global Proper ties menu allo ws you to pause if an aler t message has been displa yed, to vie w display boot inf or mation, and to set display and video modes. 4.5 Exiting the LSI Logic Boot BIOS Configuration Utility The Exi[...]

  • Page 65

    OpenBoot BIOS 4-7 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. CTRL+E after memor y initialization during reboot. This allows y ou to re- enable and reconfigure. The f ollowing messages ma y appear dur ing the boot process: • Adapter removed from boot order, parameters will be updated accordingly! appears when an adapt[...]

  • Page 66

    4-8 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.7.2 Identifying the FC Devices The probe-scsi-all command identifies the FC de vices on your Fusion- MPT adapter . T o show all disks a vailab le from the OpenBoot prompt, use the probe-scsi-all command. Note that this command is used regardless of whether[...]

  • Page 67

    OpenBoot BIOS 4-9 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Target 4 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 210000203710324a Port ID 73 /pci@8,700000/scsi@6 Target 6 Unit 0 Removable Read Only device PLEXTOR CD-ROM PX-20TS If the FC de vices on your IntraServer™ adapter are not identified b y your system, check the [...]

  • Page 68

    4-10 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. /upa@8,480000/SUNW,ffb@0,0 ... /pci@8,700000/IntraServer,fc@2 /pci@8,700000/IntraServer,fc@1,1 /pci@8,700000/IntraServer,fc@1 ... /pci@8,700000/IntraServer,fc@2/disk /pci@8,700000/IntraServer,fc@2/tape /pci@8,700000/IntraServer,fc@1,1/disk /pci@8,700000/Intr[...]

  • Page 69

    OpenBoot BIOS 4-11 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Y ou should use caution while issuing the follo wing commands because some commands (such as f orcing 1 Gbit/s operation on a 2 Gbit/s FC loop) could render the bus un usable. 4.7.4.1 select Command Use the select OpenBoot command to choose the adapter entr y[...]

  • Page 70

    4-12 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.7.4.3 show-children Command While you ha ve the host adapter or port selected, use the show-children command to displa y the devices currently connected to this adapter . First, select the por t or adapter shown (use the port name your system assigns): ok [...]

  • Page 71

    OpenBoot BIOS 4-13 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.7.5 Interrupt Coalescing The LSI Logic host adapters can complete multiple I/O requests per host interrupt. Interr upt coalescing is used to reduce CPU interrupts by pooling multiple disk command completions (I/O) into one interrupt. This f eature may be en[...]

  • Page 72

    4-14 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Interrupt coalescing timeout selected is 100 (256 decimal) microseconds Interrupt coalescing depth selected is 8 (8 decimal) Interrupt coalescing has been set Change will take effect after system reset Note: The system must be pow er cycled before the change[...]

  • Page 73

    OpenBoot BIOS 4-15 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. ok show-link-speed Link speed selected is autobaud Current link speed is 1 Gbaud Note: The system must be pow er-cycled before the changes tak e eff ect. It is not sufficient to ex ecute the reset-all command. 4.7.7 P ersistent De vice Naming One of the most[...]

  • Page 74

    4-16 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. Step 2. F rom the displa yed list, select a de vice to mar k persistent as shown in Figure 4.2 . Figure 4.2 Select Device Step 3. T ype ^Y (Ctrl-Y) to inser t disk name in the command line as shown in Figure 4.3 . Figure 4.3 Inserting Disk Name in Command Li[...]

  • Page 75

    OpenBoot BIOS 4-17 Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. 4.7.8 Manual Selection of FC T opology Under cer tain configurations , you ma y want to f orce the selection of FC topology and disable the auto detect mechanism in the FC adapter . This can be done on a por t-by-port basis by using the f ollowing procedure. [...]

  • Page 76

    4-18 BIOS F eatures Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved. ok 1 set-topology Topology selected is NL_Port Topology has been set Change will take effect after system power cycle ok 2 set-topology Topology selected is N_Port Topology has been set Change will take effect after system power cycle ok a set-topology Topol[...]

  • Page 77

    2 Gbit/s Fibre Channel Host Adapters User’ s Guide V er. 2.1 Cop yright © 2002 - 2005 by LSI Logic Cor poration. All rights reserved. Customer Feedbac k W e would appreciate your f eedback on this document. Please cop y the f ollowing page, add y our comments, and f ax it to us at the number shown. If appropriate, please also f ax copies of any [...]

  • Page 78

    Reader’ s Comments F ax your comments to: LSI Logic Cor poration T echnical Publications M/S E-198 F ax: 408.433.4333 Please tell us how y ou rate this document: 2 Gbit/s Fibre Channel Host Adapters User’ s Guide. Place a check mark in the appropr iate b lank for each categor y . What could we do to improv e this document? If you f ound errors [...]