A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Lumiscope sw-1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lumiscope sw-1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Lumiscope sw-1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Lumiscope sw-1000 should contain:
- informations concerning technical data of Lumiscope sw-1000
- name of the manufacturer and a year of construction of the Lumiscope sw-1000 item
- rules of operation, control and maintenance of the Lumiscope sw-1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lumiscope sw-1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lumiscope sw-1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lumiscope service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lumiscope sw-1000.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Lumiscope sw-1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Transcutaneous Electrical Model SW-1000 Opera tion Manual Nerve Stimulation (TENS) Read this manual bef ore oper ating the TENS device Sa v e th is m an ua l f or fut ur e us e . T he m os t cu rr ent v e rs ion o f th is m an ua l c a n b e f ound online a t ww w . gr ah am fiel d. co m[...]
-
Page 2
[...]
-
Page 3
TABLE OF CONTENTS INTRODUCTION TO TENS INDICA TIONS AND CONTRAINDICA TIONS WARNINGS PRECAUTIONS/ADVERSE REACTIONS ABOUT THIS DEVICE UNIT CONTROLS A TT ACHING THE LEAD WIRES ELECTRODE SELECTION AND CARE TIPS FOR SKIN CARE CONNECTING THE TENS DEVICE BA TTERY INFORMA TION CARING FOR YOUR TENS DEVICE TROUBLESHOOTING WARRANTY SYSTEM COMPONENTS TECHNICAL[...]
-
Page 4
INTRODUCTION TO TENS What is Pain? Pain is the body’s warning system. Pain is important because it signals an unusual condition in the body and alerts us before additional damage or injury can occur . TENS was developed to help relieve some types of chronic and acute pain. How does TENS work? TENS is a method of treating pain that is non-inv asiv[...]
-
Page 5
- - - - Contraindications Patients with implanted electronic devices ( for example, a pacemaker ) or metallic implants should not undergo TENS treatment without first consulting a physician. Any elec tro de pl acem ent that appl ies curr ent to the caro tid (nec k) re gion . Any electrode placement that causes current to flow tr anscerebrally (thro[...]
-
Page 6
MODE (uS) P ULSE WI DTH (Hz) P ULSE RA TE Lead Connector Intensity Controls Indicator Light Pulse Width Control Mode Selector Pulse Rate Control Battery Compartment Battery Strip 03 60 100 180 230 250 1 60 115 150 10 PRECAUTIONS/ADVERSE REACTIONS Caution: Isolated cases of skin irritation may occur at the site of electrode placement during long ter[...]
-
Page 7
ABOUT THIS DEVICE Y our TENS device is a battery operated device that includes two controllable output channels. This TENS device creates electrical impulses whose ampli- tude, duration, and modulation can be altered with the controls or switches. T h e TE NS in te ns it y c o n tr ol s ar e ve ry ea sy to us e, an d th e sl id e co ve r pr ot ec t[...]
-
Page 8
Mode Functions Burst (B) releases individual bursts twice per second, pulse width is adjustable and the pulse rate is set at 100Hz per second. Continuous (C) stimulation is delivered continuously at the settings deter- mined by intensity , rate, and width knobs. Modulation (M) pulse width decreases the pulse width down to 60% of the original width [...]
-
Page 9
TIPS FOR SKIN CARE Good skin care is important for effective and comfortable use of your TENS device. Always clean the electrode site with mild soap and water solution, rinse well and dry thoroughly prior to any electrode application. Any excess hair should be clipped, not shaved, to ensure good electrode contact with the skin. If a skin treatment [...]
-
Page 10
3. Place electrodes on the skin Place the electrodes on the skin as recommended by your clinician. 4. Insert the Lead Wire Connector to the TENS device Plug the end of the lead wire into the lead connector port to be used, pushing plug in as far as it will go. 5. Select T reatment Settings Ensure the unit is set to the proper settings (Pulse Width,[...]
-
Page 11
Changing the battery When the yellow indicator light on the front of the unit does not light up when the unit is turned on, the battery should be replaced. 1. Remove the panel cover by pressing o n the top and sliding down until it is completely removed from the unit. This will rev eal the battery compartment. 2. Remo ve the discharged battery from[...]
-
Page 12
TROUBLESHOOTING If the TENS device does not function properly: 1. Make sure the battery is properly installed or replace the battery . Be sure to observe proper polarity markings when replacing the battery . If the yellow light on the front of the unit does not stay lit when the unit is turned on, replace the battery and check again. 2. If the ON/O[...]
-
Page 13
TECHNICAL SPECIFICATIONS Dual, isolated between channels Burst, Continuous, Modulation Adjustable 0-80mA peak into 500 ohm load each channel, constant current 1Hz-150Hz (adjustable) 60uS-250uS (adjustable) Burst consists 2 burst per sec at 100 Hz Asymmetrical Bi-Phasic square pulse 0-100 V olt (open current) 9 volt battery 95(H) x 65(W) x 23.5 (T) [...]
-
Page 14
[...]
-
Page 15
[...]
-
Page 16