A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lutron Electronics Switch, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lutron Electronics Switch one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lutron Electronics Switch. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lutron Electronics Switch should contain:
- informations concerning technical data of Lutron Electronics Switch
- name of the manufacturer and a year of construction of the Lutron Electronics Switch item
- rules of operation, control and maintenance of the Lutron Electronics Switch item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lutron Electronics Switch alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lutron Electronics Switch, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lutron Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lutron Electronics Switch.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lutron Electronics Switch item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    R Installation Guide Softswitch128 TM (XPS) and GRAFIK Systems TM (XP) Switching Panels Please Read Contents P P a a n n e e l l M M o o d d e e l l N N u u m m b b e e r r G G u u i i d d e e Softswitch128 (XPS) 2 GRAFIK Systems (XP) 3 P P a a n n e e l l D D i i m m e e n n s s i i o o n n s s Mini Panel 4 Standard Panel 5 Large Panel 6 Extra-Lar[...]

  • Page 2

    XPS24-1204ML-20-CGP____ R 2 Installation Guide for Switching Panels Panel Model Number Guide Softswitch128 TM (XPS) XPS24-120FT -CGP____ Feed-Through Model Numbers Example Number of Circuits in Panel Feed V oltage Feed- Through T ype Custom Panel Suffix Custom Panel Suffix Number of Circuits in Panel Indicates number of switching circuits in the pa[...]

  • Page 3

    Number of Circuits in Panel Indicates number of switching circuits in the panel: 4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, or 48 Feed V oltage 1, 2 Omit for dual voltage 120 for 120 V 230 for 230 V (CE) 240 for 220-240 V (non-CE) 277 for 277 V 347 for 347 V Load Circuit Rating 16 A per circuit Custom Panel Suffix Contact Lutron for options Number o[...]

  • Page 4

    Panel Dimensions Mini Panel Bottom View T op View Right Side Left Side Dimensions are in inches (mm). Front View 14.38 (365) 15.875 (403) 8.00 (203) 2.2 (56) 4.2 (107) 0.15 (4) 1.34 (34) 21.50 (546) 24.50 (622) 24.00 (610) 2.21 (56) 15.13 (384) 10.75 (273) 4.09 (104) Cover R 4 Installation Guide for Switching Panels N N o o t t e e f f o o r r R R [...]

  • Page 5

    R Installation Guide for Switching Panels 5 Dimensions are in inches (mm). Panel Dimensions (continued) Bottom View T op View Right Side Standar d Panel Left Side Front View 14.375 (365) 15.875 (403) 2.43 (62) 8.00 (203) 4.21 (107) 0.15 (4) 2.69 (68) 41.75 (1060) 59.50 (1511) 59.00 (1499) 2.43 (62) 11.00 (279) 15.125 (394) 4.15 (105) Cover N N o o [...]

  • Page 6

    R 6 Installation Guide for Switching Panels Panel Dimensions (continued) Large Panel (120/277/347 V only) Dimensions are in inches (mm). Bottom View T op View Right Side Left Side Front View 22.0 (559) 23.50 (597) 2.50 (64) 3.34 (85) 6.30 (160) 0.15 (4) 45.00 (1143) 63.50 (1613) 63.00 (1600) 18.50 (470) 22.75 (578) 6.1 (155) Cover[...]

  • Page 7

    R Installation Guide for Switching Panels 7 Panel Dimensions (continued) Extra-Large Panel (277/347 V only) Bottom View T op View Right Side Dimensions are in inches (mm). Left Side Front View 22.0 (559) 23.50 (597) 3.0 (76) 3.45 (88) 6.3 (160) 0.15 (4) 68.0 (1727) 82.50 (2096) 82.0 (2083) 18.5 (470) 22.75 (578) 6.1 (155) Cover[...]

  • Page 8

    Panel Mounting Panel and TUB Mounting Mounting Guidelines • For Indoor Use Only! NEMA, T ype 1 enclosure, IP20. • Large and extra-large panels for surface mount only . • Panel generates heat. Mount where ambient temperature is 32-104 ºF (0-40 ºC). • Relative humidity must be <90% non-condensing. • Reinforce wall structur e for panel [...]

  • Page 9

    R Installation Guide for Switching Panels 9 Panel Mounting (continued) Rough-In Panel Inter ior Mounting (Rough-in Panels ONL Y) (120/277/347 V only) Mounting for SINT or XINT Plate: • Insert interior into TUB. • Rest interior on bottom of TUB. • Press inter ior flat into back of TUB. • Insert 3 screws (pr ovided) as shown into interior to [...]

  • Page 10

    R 10 Installation Guide for Switching Panels • Use a trough when the switching panel is far away fr om the distribution panel. Splice neutrals in trough. • Wire the switching panel similar to a lighting distribution panel. Run feed and load wir ing. • Use the switching panel to provide temporary lighting by leaving the bypass jumpers in place[...]

  • Page 11

    R Installation Guide for Switching Panels 11 Wir ing (continued) H SH H SH H SH H SH H SH Panel with Branch Cir cuit Br eakers: Feed and Load Wir ing (120/277/347 V only) Bypass jumpers - do not remove Load Neutral bus Neutral bus Main lugs Branch circuit breakers for temporary lighting Wiring Tips • Wire the switching panel similar to wiring a l[...]

  • Page 12

    R 12 Installation Guide for Switching Panels Wir ing (continued) L SL N L SL N L SL N L SL N Panel with Isolation Switch: Feed and Load Wir ing (230/220-240 V only) Bypass jumpers - do not remove Load Ground bus Main feeds: Phase A, B, C, and Neutral Wiring Tips • Wire the switching panel similar to wiring a lighting distr ibution panel. • Run [...]

  • Page 13

    R Installation Guide for Switching Panels 13 System Wir ing Overview Review the options below for information on wiring your panel corr ectly into your specific system. A. Softswitch128 TM (XPS) panel: Refer to the Softswitch128 Setup and Operation Manual for detailed wiring information. B. GRAFIK Systems TM (XP) panel as a part of a GRAFIK Eye 400[...]

  • Page 14

    R 14 Installation Guide for Switching Panels Ratings Softswitch128 TM (XPS) 3Ø 4W or 1Ø 3W Main Lug Accepts: #4 AWG to 250 KCMIL (MCM) (25-120 mm 2 ) 120 V Panels with Branch Circuit Br eakers XPS Model Switch Legs Feed T ype Max Feed XPS8 XPS12 XPS16 XPS20 XPS24 XPS28 XPS32 XPS36 XPS40 XPS42 8 12 16 20 24 28 32 36 40 42 200 A 225 A Use the chart[...]

  • Page 15

    R Installation Guide for Switching Panels 15 Ratings (continued) GRAFIK Systems TM (XP) 3Ø 4W or 1Ø 3W Main Lug Accepts: #4 AWG to 250 KCMIL (MCM) (25-120 mm 2 ) 120 V Panels with Branch Circuit Br eakers XP Model Switch Legs Feed T ype Max Feed XP4 XP8 XP12 XP16 XP20 XP24 XP28 XP32 XP36 XP40 XP42 4 8 12 16 20 24 28 32 36 40 42 200 A 225 A Use th[...]

  • Page 16

    R 16 Installation Guide for Switching Panels Activate Loads in Bypass A. Complete load wiring. B. Check that the bypass jumpers ar e in place. These jumpers protect fr om load faults and must be used to check load wiring when it is installed or modified. W ar ning! V erify that the panel is fed from the corr ect voltage. A feed miswire or loss of a[...]

  • Page 17

    R Installation Guide for Switching Panels 17 Complete Installation Remove Bypass Jumpers A. After all load wiring has been checked, turn circuit breakers OFF . B. Remove and store the bypass jumpers for possible future use. C. T ur n cir cuit breakers ON. Caution! Reuse the bypass jumpers whenever work is being done on a load. Damage caused by shor[...]

  • Page 18

    R 18 Installation Guide for Switching Panels Notes[...]

  • Page 19

    R Installation Guide for Switching Panels 19 W arranty L L u u t t r r o o n n E E l l e e c c t t r r o o n n i i c c s s C C o o . . , , I I n n c c . . O O n n e e Y Y e e a a r r L L i i m m i i t t e e d d W W a a r r r r a a n n t t y y For a period of one year from the date of purchase , and subject to the exclusions and restrictions describ[...]

  • Page 20

    R Lutron Electronics Co., Inc. Made and printed in U.S.A. 09/06 P/N 032-162 Rev . A Contact Information Internet: www .lutron.com E-mail: product@lutr on.com WORLD HEADQUARTERS USA Lutron Electr onics Co., Inc. 7200 Suter Road, Coopersburg, P A 18036-1299 TEL +1.610.282.3800 F AX +1.610.282.1243 T oll-Free 1.888.LUTRON1 T echnical Support 1.800.523[...]