Lux Products 3M-22 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lux Products 3M-22, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lux Products 3M-22 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lux Products 3M-22. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lux Products 3M-22 should contain:
- informations concerning technical data of Lux Products 3M-22
- name of the manufacturer and a year of construction of the Lux Products 3M-22 item
- rules of operation, control and maintenance of the Lux Products 3M-22 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lux Products 3M-22 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lux Products 3M-22, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lux Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lux Products 3M-22.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lux Products 3M-22 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    • Your thermostat is a precise instrument, handle it with care. • Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. • Do not turn electricity back on until work is completed. • Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the system.[...]

  • Page 2

    Location Caution Tools To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the circuit breaker, or at the appliance. Replacement installations - mount the new thermostat in place of the old one. New installations - follow the guidelin[...]

  • Page 3

    Remove old unit Prepare wires IMPOR TANT : LABEL ALL WIRES BEFORE DISCONNECTING THEM! • Switch electricity to the furnace and air conditioner OFF ; then proceed with the following steps. • Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened. Note the[...]

  • Page 4

    Before you Connect Wires Caution Do not allow wires to touch each other or parts on thermostat. Please follow these guidelines for safe and secure wire connections. • Easy Terminals do not require stripping the wire. • Clip any bare wire from previous installation. • T ake care not to damage the labels for each wire in handling. • Fan wires[...]

  • Page 5

    • If you combination of wires is not above you can use the wiring table on pages 24-25 to deter m ine your connections, or call our US A support line at 1-888-607-5824 for help. • Find the referenece page with your wiring diagram and jumper set-up information. Remembe r , the C wire is optional. Find the set-up diagram for your system PG 7 PG 8[...]

  • Page 6

    PG 9 PG 10 Install AAA Batteries • The 3M-22 requires 2 AA A batteries to operate . • Switch MODE switch to OFF and the FAN switch to AUTO. • Install 2 AAA alkaline batteries according to the polarity noted in the compartment. LCD segments will go on. • Press the RESET button (under top cover) to clear transient progra m memor y . NOTE: Rep[...]

  • Page 7

    NOTE: If you have labeled your wires, follow the correct Step-By-Step, and these Check procedures do not operate your system call support at 1-888-607-5824 Check Unit Follow these procedures to verify you have correctly installed the 3M-22. To check Fan: (If you connected the G wire - fan relay) • Switch the FAN switch to the ON position. Verify [...]

  • Page 8

    BATTERIES ON LY - This ther mostat can run on batteries only using 2AAA alkaline batteries. The batteries will last at least 1 year; replace the batteries once a year or when the low battery icon comes on the displa y . If the batteries are not replaced, the thermostat will shut off the H VAC and then stop working. 24 VAC - This ther mostat can run[...]

  • Page 9

    PG 15 2 WIRE HE AT Heating GAS MILLIVO LT or 24vac NOTE: Wires marked with dotted line are optional. PG 16 3 Wire Heat 3M-22 W R C GAS Milivolt Heat C B O W 2 W Y Y 2 RH RC G A 3M-22 W R G C HVAC SYSTEM C B O W 2 W Y Y 2 RH RC G A STEP 1 - Connect the R (or RH) wire to the RH terminal on the 3M-22. This connects the Heater Power to the thermostat. [...]

  • Page 10

    STEP 1 - Connect the W wire to the W terminal on the thermostat. This connects to the heater control line. STEP 2 - Connect the Y wire to the Y terminal on the 3M-22. This connects to the Cooler compresso r . STEP 3 - Connect the RH wire to the RH terminal and the RC wire to the RC terminal on the 3M-22. This connects the Heater and Cooler Powe r .[...]

  • Page 11

    STEP 1 - Connect O wire to the O terminal or B wire to the B terminal on the 3M-22. (If you have both O and B - connect O wire to O terminal DO NOT connect B to B terminal - see pg 24 Trane for B wire terminal) This connects the change-over valve. STEP 2 - Connect the Y wire to Y on the 3M-22. This connects the Compresso r . STEP 3 - Connect the R [...]

  • Page 12

    W R A Motor Valve C B O W 2 W Y Y 2 RH RC G A PG 22 W RH [A?] 3 Zoned Hot Water - Motor Valve Step 1 - based on your valve type Motor driven Valve- Connect the R (or RH) wire to the RH terminal on the 3M-22. Connect the W wire to the W terminal on the 3M-22. Connect the remaining wire to the A terminal. Solenoid valve - Connect the R (or RH) wire t[...]

  • Page 13

    This thermostat can be used with all millivolt and 24 VAC heating and cooling systems. It cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can easily be set on the large screen with the +/- buttons on the front. A minimum 4 minute off time protects heating and cooling systems from damag[...]

  • Page 14

    1002-005 Customer Support: 888-607-5824 or Visit our website ww w .radiothermostat.com/filtrete Printed in China Wire Reference cont Your Wires Filtrete Terminal Lennox Heat Pump V or VR or R RH M or Y Y Y or W or W2 W2 F or G G R or O O X or X2 or C C Trane Products [American Standard] B C W or W1 W2 Zoned Systems Your Wires Filtrete Terminal 2 wi[...]