Go to page of
Similar user manuals
-
Thermostat
Lux Products PSM40SA
4 pages 0.23 mb -
Thermostat
Lux Products DMH100
2 pages 0.2 mb -
Thermostat
Lux Products CH400SA
4 pages 0.16 mb -
Thermostat
Lux Products LHP-750
1 pages 0.67 mb -
Thermostat
Lux Products TX9100E
32 pages 0.66 mb -
Thermostat
Lux Products SMART TEMP TX9100E
32 pages 0.7 mb -
Thermostat
Lux Products T20-1141SA
2 pages 0.13 mb -
Thermostat
Lux Products TX9000
5 pages 0.37 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Lux Products PSPU721T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lux Products PSPU721T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Lux Products PSPU721T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Lux Products PSPU721T should contain:
- informations concerning technical data of Lux Products PSPU721T
- name of the manufacturer and a year of construction of the Lux Products PSPU721T item
- rules of operation, control and maintenance of the Lux Products PSPU721T item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lux Products PSPU721T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lux Products PSPU721T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lux Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lux Products PSPU721T.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Lux Products PSPU721T item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
3-YEAR WARRANTY INSTRUCTION MANUAL LUXPRO ® PSPU721T 2 Heating and 1 Cooling with Dual Fuel Switch LUX Products Corporation 6000 Commerce Parkway , Suite-I • Mt. Laurel, NJ 08054 (856) 234-7905 • F AX (856) 234-7825 http://www.luxproproducts.com 52077[...]
-
Page 2
2 LUXPRO ® PSPU721T[...]
-
Page 3
O O U U T T D D O O O O R R W W I I R R E E L L E E S S S S T T E E M M P P E E R R A A T T U U R R E E T T R R A A N N S S M M I I T T T T E E R R A A N N D D R R E E C C E E I I V V E E R R K K I I T T LUXPRO ® Part No. WTR064 Outdoor Wireless T emperature T ransmitter and Receiver Kit Includes: T ransmitter Antenna Receiver Module 2 AA Batterie[...]
-
Page 4
LUXPRO ® PSPU721T Introducing the LUXPRO ® PSPU721T touch-screen thermostat with 2-stage heating, 1-stage cooling control and fossil fuel switch (Available only when combined with LUXPRO ® Outdoor Wireless T ransmitter and Receiver Kit. LUXPRO ® Part No. WTR064) • 7 Day programmable with 4 events per day - including fan • Large, easy to rea[...]
-
Page 5
T ABLE OF CONTENTS ...................................................................................................................5 GLOSSARY OF TERMS ..................................................................................................................6 SELECTING A LOCA TION ..........................................................[...]
-
Page 6
GLOSSAR Y OF TERMS 6 LUXPRO ® PSPU721T CYCLE RA TE - Cycle rate is the frequency that heating or cooling equipment is turned on during a certain period of time. Cycle rate is often given in units of cyc les per hour (CPH). DIFFERENTIAL - Differential is defined as the difference between the cut-in and cut-out points as measured at the thermostat u[...]
-
Page 7
Install your LUXPRO ® thermostat approximately 5 feet (1.5 meters) above the floor in an area with good air circulation. Avoid the following locations: • Hot or cold air from ducts • Radiant heat for appliances or sun such as a skylight • Unheated or uncooled areas: for example an outside wall behind the thermostat. • Ensure that there is [...]
-
Page 8
MOUNTING THE THERMOST A T TO THE WALL 8 LUXPRO ® PSPU721T 1. Make sure to turn off the power supply located at the electrical ser vice panel. All heating and cooling units should be OFF . 2. Separate the backplate from the thermostat by grasping the unit firmly a t the bottom lip and pulling gently until the two piece are apart. 3. Align the backp[...]
-
Page 9
TERMINAL EQUIPMENT ST ANDARD COLOR Y1 First Heat Pump and AC Y ellow G Fan Green W2 First Stage Furnace White OBW Reverse Valve - Second Stage Furnace Orange RH 24v Red Y2 Not Used Unknown C Common Blue H Not Used Unknown DH Not Used Unknown RC 24v Unknown 11 and 12 Not Used NOTE: The above colors are standard in HV AC industry. The wiring should b[...]
-
Page 10
WIRING DIAGRAMS 10 LUXPRO ® PSPU721T I2 1 AIR CONDITIONER 24V FAN AC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON[...]
-
Page 11
HEAT 2 HEAT 1 I2 1 AIR CONDITIONER AND 2 STAGE HEA T 24V FAN AC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON HEAT I2 1 AIR CONDITIONER AND 1 STAGE HEA T 24V FAN AC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON WIRING DIAGRAMS 11 INSTRUCTION MANUAL[...]
-
Page 12
HEAT REVERSE VAL VES I2 1 HEA T PUMP AND 1 STAGE HEA T 24V FAN HP I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON WIRING DIAGRAMS 12 LUXPRO ® PSPU721T REVERSE VAL VES I2 1 HEA T PUMP 24V FAN HP I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON[...]
-
Page 13
WIRING DIAGRAMS 13 INSTRUCTION MANUAL HEAT TRANSFORMER COOL TRANSFORMER I2 2 TRANSFORMERS I1 RC DH H C Y2 CUT RH OBW W2 G Y1 I2 1 TRANSFORMER I1 RC DH H C Y2 RH OBW W2 G Y1 HEAT TRANSFORMER[...]
-
Page 14
Current Room T emperature Current Outdoor T emperature Current Thermostat Operation Mode Current T emperature Control Mode Current Fan Operation Mode Fan Operation Indicator Vacation Mode Indicator Security Indicator Heat setpoint Cool setpoint Date Time HOME SCREEN 14 LUXPRO ® PSPU721T > > T o return to the HOME SCREEN, simply touch the ico[...]
-
Page 15
Change the T emperature Setpoint(s) using - and + buttons. In AUTO MODE toggle the Heat/Cool button (Hea t or Cool will flash once selected), then raise or lower setpoints as desired. Select the Thermostat Opera tion Mode by toggling thermostat operation mode button. Select the T emperature Control Mode by toggling the temperature control mode butt[...]
-
Page 16
THERMOST A T OPERA TION MODES 16 LUXPRO ® PSPU721T > > LUXPRO ® thermostat can operate in PROGRAM MODE or can HOLD a fixed temperature. RUN PROGRAM : the thermostat initiates the 7-day Programmable T emperature Control Program with 4 independent events per day . T o set up a custom tem- perature control program with customizable T empera tu[...]
-
Page 17
> > Based on your HV AC equipment LUXPRO ® thermostat can operate in the following temper- ature control modes - AUTO or HEA T or EMERGENCY HEA T or COOL or OFF AUTO - the thermostat keeps the room temperature between the selected HEA T and COOL setpoints by using both the cooling and heating HVAC units. HEA T - the thermostat only turns on [...]
-
Page 18
F AN OPERA TION MODES > > LUXPRO ® thermostat can operate the fan in one of the following three modes: F AN AUTO : The fan runs only when there is a demand for heating or cool- ing. F AN ON : The fan runs continuously F AN INTERMITTENT : The fan runs 10 minutes per 1/2 hour providing a convenient way to improve air quality and save energy. W[...]
-
Page 19
INSTRUCTION MANUAL 19 GLOSSAR Y OF TERMS[...]
-
Page 20
MENU SCREEN > > T o access the MENU SCREEN, simply touch MENU from the CONTROL SCREEN. > > From the MENU page, you can: Access DA TE AND TIME SETTINGS to enter the accurate date and time Access PROGRAM SETTINGS to pre-program temperature changes during each day of the week. Access ENERGY WA TCH to display kWh consumption and the dollar [...]
-
Page 21
MENU SCREEN Access V ACA TION SETTINGS to activate the V ACA TION MODE Access FIL TER MONITOR to review days of "fan run time." Access ADV ANCED SETTINGS to configure the thermostat. T o access the ADV ANCED SETTINGS, hold the ADVANCED SETTINGS button for 5 sec- onds. the thermostat will continuously beep for 5 seconds to indicate that yo[...]
-
Page 22
D A TE AND TIME SETTINGS Select the 12 OR 24 HOUR CLOCK display by pushing the corresponding button. Set the TIME by togggling hour , minute and AM/PM buttons. Set the DATE by toggling Month, Day and Y ear buttons. 22 LUXPRO ® PSPU721T[...]
-
Page 23
PROGRAM SETTINGS PROGRAM SETTINGS feature allows you to easily and quickly program daily temperature changes to fit your lifestyle and reduce energy con- sumption. Y ou can customize the program for each day of the week with 4 independent temperature and fan operation settings per day. T o setup your program: Select the DA Y OF THE WEEK Select the [...]
-
Page 24
ENERGY W A TCH ENERGY WA TCH feature provides a report on the energy consumption and the dollar cost of operating your HVAC system (for up to the last 255 days). Once the cost of the kWH per compressor , furnace and fan have been entered into the ENERGY WA TCH Settings (see page 28) Energy W atch will display the consumption as well as the real tim[...]
-
Page 25
SET SCREEN OPTIONS • BACKLIGHT : Select between automatic and permanent backlight for the screen. AUTO: The screen back-light will come on only when you touch the screen. ON: Screen will constantly be back-lit. • REVERSE : Select the positive or negative screen display . ON: Negative Display (Dark Background) OFF: Positive Display (Light Backgr[...]
-
Page 26
V AC A TION MODE > > V ACA TION SETTINGS allows you to set the temperature to a fixed setpoint during the time you are on vacation, providing energy savings without compromising comfort upon your return. IMPORT ANT : HEA T or COOL must be selected from the CONTROL SCREEN before entering the Vacation Settings screen. T o begin select Vacation [...]
-
Page 27
FIL TER MONITOR FIL TER MONITOR: Displays filter usage in days RESET : Resets filter timer (Y ou should reset FIL TER MONITOR after chang- ing the air filter . When activated the FIL TER MONITOR icon appears on your HOME SCREEN - this feature must be activated in ADV ANCED SETTINGS. INSTRUCTION MANUAL 27[...]
-
Page 28
• DA YLIGHT TIME : Choose Daylight Time ON or OFF dependent on your Time Zone. FIL TER: Enter the air filter "fan run time" infor- mation here. The Filter Monitor feature uses this information to inform you when to change your air filter by displaying CHANGE FIL TER icon on the HOME SCREEN. ENERGY WA TCH: Enter the HV AC system con- sum[...]
-
Page 29
SECURITY : The security settings allow you to protect your LUXPRO ® thermostat from unautho- rized use. T urn Security ON or OFF . Y ou will be prompted to enter the PIN. The Default PIN 1111. To CHANGE PIN , enter your new PIN and then, when prompted, re-enter your new PIN. Choose a security mode by toggling SECURITY MODE button: FULL LOCK does n[...]
-
Page 30
ADV ANCED SETTINGS - SY STEM CONFIGURA TION ! IMPORT ANT : By inadvertently modifying system configuration settings, you may seriously degrade HV AC system performance. > > Choose system heating and cooling equipment - remember all you need to do is toggle the appropriate button until the correct setting appears. • Choose HEAT PUMP or 2 ST [...]
-
Page 31
ADV ANCED SETTINGS - DUAL FUEL SWITCH ! IMPORT ANT : This feature can only be activ ated when used with the LUXPRO ® Outdoor Wireless T emperature T ransmitter and Receiver . Please install the LUXPRO ® Outdoor Wireless T emperature T ransmitter and Receiver before activ ating this feature. Increasing energy efficiency and reducing costs can be a[...]
-
Page 32
ADV ANCED SETTINGS - DIFFERENTIAL SETTINGS > > LUXPRO ® PSPU721T allows you to control up to 2 Stages of Heating and 1 Stage of Cooling, dependent on the type of system you have configured. • 1ST ST AGE DIFFERENTIAL : Set tempera ture difference between temperature set point and actual temperature reading before 1st stage heating or coolin[...]
-
Page 33
ADV ANCED SETTINGS - TIMER FEA TURE • Specify the number of minutes for which Stage 1 will function until Stage 2 is activated to help raise (or cool) temperature (if the temperature set point is not reached). This unique function avoids excess compressor wear in the case where the necessary tempera ture set point is not met through setting of th[...]
-
Page 34
ADV ANCED SETTINGS - HEA T PUMP • HP ON when Furnace On: Hea t Pump and Furnace can operate together when 2nd stage fur- nace is required. HP “OFF” when Furnace On: turns off the Heat Pump when the furnace is On (required on some gas or oil furnaces). 34 LUXPRO ® PSPU721T[...]
-
Page 35
INSTRUCTION MANUAL 35[...]
-
Page 36
ADV ANCED SETTINGS - C ALIBRA TION > > Calibration of T emperature Y our LUXPRO ® thermostat is rated for a temperature accuracy of ±1°F (±0.5°C) If you have determined due to drafts, sunlight or other environmental factors that your thermostat requires calibration, follow this easy guide. Common cause of offset are lack of air circulati[...]
-
Page 37
ADV ANCED SETTINGS - C ALIBRA TION > > T emperature Calibration T able • Determine the temperature difference using an accurate thermometer and use the following table to calibrate your thermostat. The thermostat temperature reading can be calibra ted by ±19°F (±9.5°C). INSTRUCTION MANUAL 37 Calibration Number °C Change °F Change ±0.[...]
-
Page 38
SIMPLE THERMOST A T MODE > > LUXPRO ® thermostat can also function as a virtual non-programmable thermostat after it has been switched to a “SIMPLE MODE”. > > T o enable “SIMPLE MODE”, press the reset button (take off the thermostat faceplate and press the reset button located in the bottom right-hand corner). The message “T [...]
-
Page 39
TROUBLESHOO TING ? T ouch screen buttons do not function properly . Remove cover , press the reset button loca ted in the bottom left corner then accurately touch 3 target centers on the screen when prompted. ? Air conditioning turns on in HEA T mode and heating turns on in COOL mode. Reverse the OB valve (see “Advanced Settings” Page 36). ? P [...]
-
Page 40
IMPOR T ANT NO TICE > > WHEN USING THIS THERMOST A T WITH A GAS FURNACE A COMMON WIRE (C) MUST BE CONNECTED. When working without a common wire: > > A confirm in HEA T MODE the cooling does not switch on or B confirm in COOL MODE the heat does not switch on. > > If test A or B fail or the thermostat shuts do wn in either HEA T or [...]
-
Page 41
W ARRANTY HARDWARE LUX Products Corporation warrants the original end user (“Customer”) that new LUXPRO ® branded products will be free from defects in workmanship and materials, under normal use, for three (3) years from the original purchase date. SOFTWARE LUX Products Corporation warrants to Customer that the LUXPRO ® thermostat software w[...]
-
Page 42
42 LUXPRO ® PSPU721T[...]
-
Page 43
43 INSTRUCTION MANUAL[...]
-
Page 44
FCC ST A TEMENT THIS DEVICE COMPLIES WITH PAR T 15 OF THE FCC RULES. OPERA TION IS SUB- JECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MA Y NOT CAUSE HARMFUL INTER- FERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTER- FERENCE THAT MA Y CAUSE UNDESIRED OPERA TION. TECHNICAL ASSIST ANCE If you have any problems [...]