Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Manhattan CCD Barcode Scanner, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Manhattan CCD Barcode Scanner one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Manhattan CCD Barcode Scanner. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Manhattan CCD Barcode Scanner should contain:
- informations concerning technical data of Manhattan CCD Barcode Scanner
- name of the manufacturer and a year of construction of the Manhattan CCD Barcode Scanner item
- rules of operation, control and maintenance of the Manhattan CCD Barcode Scanner item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Manhattan CCD Barcode Scanner alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Manhattan CCD Barcode Scanner, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Manhattan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Manhattan CCD Barcode Scanner.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Manhattan CCD Barcode Scanner item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
BAR CODE BAR CODE[...]
-
Page 2
Progra mming Menu V3.8 a Notice The ma nufa cturer shall not be li a ble f or te chnical or editorial errors or omissions contained herein; nor f or incidental or con sequenti al da mage s in conne ction with the furnishing,perf orma nce or use of use the publication.[...]
-
Page 3
1 Contents Cha pter 1 Description 1.1 Notice ....................................................... 3 1.2 Introduction ........................................... 4 1.3 Codes Read ........................................... 4 1.4 Installation .............................................. 4 1.5 Pin Assign ment .....................................[...]
-
Page 4
2 5.12 Code 2 of 6 Para meters ......................... 44 5.13 LCD 25 Para meters ............................. 46 5.14 T ele pen Para meters ............................. 48 5.15 GS1 DataBar (RSS Code) ........................ 50 Cha pter 6 M iscella neous Para meters 6.1 La nguage Sele ction .............................. 52 6.2 Bar Code ID ...[...]
-
Page 5
3 Cha pter 1 De scri ption 1.1 General Tha nk you f or purcha sing this barcode sca nner with a n a dva nced a nd versatile de coder .The de coder works with variety of barcode types,reading devices, a nd computer interfa ce s.It discri min ate s over twenty different symbologies automatically. This menu provide s a n e a sy way to conf igure the d[...]
-
Page 6
4 1.2 Introduction The De coder is a n a dva nced a nd versatile de coding fa cility f or barcoding syste ms .It work s with variety of bar code types, reading devices, a nd computer interfa ce s. It discri min ate s a bout twenty different symbologies automatically. This menu provide a n e a sy way to conf ig the de coding option s a nd interfa ce[...]
-
Page 7
5 Power supply for RS-232C scanner– There are 3 ways to supplying the power, use ex- ternal +5V power supply, use optional power cable (KBDC) which ta king the power from KB wedge or if the host supports +5V power from pin 9. Installing the scanner to the Host System – 1. Turn off the host system. 2. Connect the power if needed. 3. Connect to t[...]
-
Page 8
6 1.5 Pin Assignment A> Input Port for Mini Decoder DB 9 Male Pin No. W a nd / CCD / Slot Reader La ser Sca nner 1 N.C. S.O.S. 2 DA T A DA T A 3 N.C. N.C. 4 N.C. N.C. 5 N.C. TRIGGER 6 N.C. P. E. 7 GND GND 8 SHIELD SHIELD 9 +5V +5V B> Output Port 1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CL[...]
-
Page 9
7 6 1 5 9 1 2 4 3 1 3 2 4 6 7 8 5 2 1 3 4 2 5 1 3 8 7 6 4 6 1 5 9 2. RS-232 Output DB 9 Female Pin No. Function 2 TXD 3 RXD 5 GND 7 CTS 8 RTS Power Lead Vcc (+5V) 3. W AND Emulation Output DB 9 Female Pin No. Function 2 DA T A 7 GND 9 Vcc (+5V) 4. ADB Interface MiniDIN 4 MALE MiniDIN 4 FEMALE Pin No. Function Pin No. Function 1 ADB 1 ADB 3 Vcc 3 Vc[...]
-
Page 10
8 Cha pter 2 Conf iguration - General 2.1 Flow Chart[...]
-
Page 11
9 2.2 Loop of Progra mming The philosophy of progra mming para meters ha s been shown on the flow chart of 2.1. Ba sically user should 1.Sca n Start of Conf iguration. 2.Sca n all ne ce ssary la bels f or para meters that meet a pplication s. 3.Sca n End of Conf iguration to end the progra mming. 4.T o perma nently save the settings you progra mmed[...]
-
Page 12
10 % $ + / 0 % $ + / 1 % $ + / 2 % $ + / 3 % $ + / 4 % $ + / 6 % $ + / 5 2.4 Main Page of Configuration Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Inf ormation Save Para meters - The para meter settings will be saved perma nently . Re call Stored Para meters - Re pl[...]
-
Page 13
1 1 Cha pter 3 Interf a ce a nd Re a ding Mode Sele ction 3.1 Interface Selection <Keyboard Mode> RS232 Mode WAND Emulation USB Mode 3.2 Memory Function<HC102M Only> <Enable> Disa ble % 0 0 U0 % 0 0 U8 % 0 0 M 2 % 0 XI 2 % 0 XI 0 % 0 XO 8[...]
-
Page 14
12 3.3 Reading Mode Selection <Good Read OFF> Trigger ON/OFF Continuous/Trigger OFF T e sting Continuous/Auto Power On Fla sh Fla sh/Auto Power On Reserved1 Re served 2 ( Auto Sen se Option) Reserved3 Reserved4 Reserved5 % 0 2 7 1 % 0 2 7 0 % 0 2 7 2 % 0 2 7 5 % 0 2 7 3 % 0 2 7 4 % 0 2 7 6 % 0 2 7 7 % 0 9 F 8 % 0 9 F 9 % 0 9 F A % 0 9 F B[...]
-
Page 15
13 Ch.4 Communication Para meters 4.1 RS232 Communication Para m eters A> Set Up BAUD Rate 1200 2400 4800 <9600> 19200 38400 B> Set Up Data Bits 7 Data Bits <8 Data Bits> C> Set Up Stop Bits <1 Bit> 2 Bits % 0 Y8 0 % 0 Y8 8 % 0 Y7 1 % 0 Y7 2 % 0 Y7 3 % 0 Y7 7 % 0 Y7 4 % 0 YO 8 % 0 YO 0 % 0 Y7 5[...]
-
Page 16
14 D> Set Up Parity <None> Even Odd Mark Spa ce E> Ha ndsha king RTS/CTS Enable <RTS/CTS Disa ble> ACK/NAK Enable <ACK/NAK Disa ble> XON/XOFF Enable <XON/XOFF Disa ble> % 0 YN7 % 0 YN2 % 0 YN3 % 0 YN1 % 0 YN0 % 0 1 8 8 % 0 1 8 0 % 0 1 4 4 % 0 1 4 0 % 0 3 K 4 % 0 3 K 0[...]
-
Page 17
15 4.2 Keyboard W edge Mode Para meters A> T ermin al T ype <IBM PC/A T , PS/2> IBM PC/XT IBM PS/2 25, 30 NEC 9800 Apple De s ktop Bus( ADB ) IBM 5550 IBM 122 Key (1) IBM 102 Key IBM 122 Key (2) Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 % 0 Z F 0 % 0 Z F 1 % 0 Z F 2 % 0 Z F 3 % 0 Z F 4 % 0 Z F 5 % 0 Z F 6 % 0 Z F 7 % 0 Z F 8 %[...]
-
Page 18
16 B> Upper/Lower Ca se <No Cha nge> Upper Ca se Lower Ca se C> Ca pslock Dete ction Enable <Disable> D> Send Chara cter by AL T Method Enable <Disable> E>Sele ct Numerical Pa d ON <OFF> % 0 3 3 0 % 0 3 3 1 % 0 3 3 2 % 0 X8 8 % 0 X8 0 % 0 3 O 8 % 0 3 O 0 % 0 1 K4 % 0 1 K0[...]
-
Page 19
17 4.3 Output Chara cters Para meters A> Sele ct T ermin ator <CR+LF> None CR LF Spa ce HT(T AB) STX-ETX % 7 S0 + % 7 S2 + % 7 S4 + % 7 S5 + % 7 S7 + % 7 S1 + % 7 S3 +[...]
-
Page 20
18 B> Time-out Between Characters <0 ms> 5 ms 10 ms 25 ms 50 ms 100 ms 200 ms 300 ms % 0 0 7 0 % 0 0 7 1 % 0 0 7 2 % 0 0 7 3 % 0 0 7 4 % 0 0 7 5 % 0 0 7 6 % 0 0 7 7[...]
-
Page 21
19 4.4 W a nd Emulation Mode Para meters A> TTL Level Re pre sentation <Bar Equals High> Bar Equals Low B> Sca n Speed Sele ction <Fa st> Slow C> Output Format Selection <Output a s Code 39> Output a s Code 39 Full ASCII Output a s Origin al Code Format % 0 2 K 4 % 0 2 K 0 % 0 2 8 8 % 0 2 8 0 % 0 2 O 8 % 0 2 O 0 % 0 XK 4[...]
-
Page 22
20 Ch.5 Bar Code s & Others 5.1 Symbologies Selection UPC-A <ON> OFF UPC-E <ON> OFF EAN-13/JAN-13/ISBN-13 <ON> OFF EAN-8/JAN-8 <ON> OFF CODE 39 <ON> OFF CODE 128 <ON> OFF CODABAR/N W7 <ON> OFF % 0 A4 4 % 0 A4 0 % 0 BO 8 % 0 BO 0 % 0 A2 2 % 0 A2 0 % 0 A1 1 % 0 A1 0 % 0 EO 8 % 0 EO 0 % 0 F O 8 % 0 F O 0 %[...]
-
Page 23
21 Interleave 25 <ON> OFF Industrial 25 ON <OFF> Matrix 25 ON <OFF> CODE 93 ON <OFF> CODE 1 1 ON <OFF> China Postage ON <OFF> MSI/PLESSEY ON <OFF> % 0 G O 8 % 0 G O 0 % 0 HO 8 % 0 HO 0 % 0 I O 8 % 0 I O 0 % 0 KO 8 % 0 KO 0 % 0 L O 8 % 0 L O 0 % 0 M O 8 % 0 M O 0 % 0 NO 8 % 0 NO 0[...]
-
Page 24
22 Code 2 of 6 ON <OFF> LCD25 ON <OFF> T ele pen ON <OFF> Reserved5 ON <OFF> Reserved6 ON <OFF> % 0 PO 8 % 0 PO 0 % 0 Q O 8 % 0 Q O 0 % 0 RO 8 % 0 RO 0 % 0 SO 8 % 0 SO 0 % 0 T O 8 % 0 T O 0[...]
-
Page 25
23 % 0 UO 8 % 0 UO 0 % 0 VO 8 % 0 VO 0 % 1 A/ + % 0 W O 8 % 0 W O 0 GS1 DataBar Omnidire ction al ON <OFF> GS1 DataBar Li mited ON <OFF> GS1 DataBar Expa nded ON <OFF> Sele ct All Bar Code s[...]
-
Page 26
24 5.2 UPC/EAN/JAN Para meters A> Re a ding T ype UPCA=EAN13 ON UPCA=EAN13<OFF> ISBN-10 Enable ISBN-13 <Enable> ISSN Enable ISSN <Disable> Decode with Supplement <Autodiscriminate Supplement> Expa nd UPC-E Enable Expa nd UPC-E <Disable> EAN8=EAN13 Enable EAN8=EAN13 <Disable> GTIN Format Enable GTIN Format <[...]
-
Page 27
25 B> Supplementals Set Up <Not T ra n smit> T ra n smit 2 Code T ra n smit 5 Code T ra n smit 2&5 Code C> Che ck Digit T ra n smission UPC-A Che ck Digit T ra n smission <ON> OFF UPC-E Che ck Digit T ra n smission <ON> OFF EAN-8 Che ck Digit T ra n smission <ON> OFF EAN-13 Che ck Digit T ra n smission <ON> O[...]
-
Page 28
26 5.3 Code 39 Para meters A> T ype of Code <Standard> Full ASCII Itali a n Pharma cy/Code 32 <OFF> Itali a n Pharma cy/ Code 32 ON B> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit C> Output Start/Stop Character Enable <[...]
-
Page 29
27 D> Decode Asterisk Enable <Disable> E> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps [...]
-
Page 30
28 5.4 Code 128 Para meters A> Re a ding T ype UCC/EAN-128 Enable <UCC/EAN-128 Disa ble> <Enable']C1'Code Format> Disa ble']C1'Code Format <En a ble Code128 Group Separators (GS)> Disa ble Code128 Group Se parators (GS) B> Che ck Digit T ra n smission Do Not Calculate Che ck Digit Calculate Check Digit &a[...]
-
Page 31
29 D> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a [...]
-
Page 32
30 5.5 Interle ave 25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit B> Set Up Number of Character <Even> Odd C> Brazilian Banking Code <Disable> Enable % 0 G N3 % 0 G N7 % 0 G N5 % 0 G 8 8 % 0 G 8 0 % 0 G 4 0[...]
-
Page 33
31 D> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a [...]
-
Page 34
32 5.6 Industri al 25 Para meters A> Reading type IA T A25 En a ble <Disable> B> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit C> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sire[...]
-
Page 35
33 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 H1 + % 4 H0 0 % 4 H0 0 % 4 H0 1 % 4 H0 2 % 2 + - / % 2 C3 +[...]
-
Page 36
34 5.7 M atrix 25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix[...]
-
Page 37
35 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 I 1 + % 4 I 0 0 % 4 I 0 0 % 4 I 0 1 % 4 I 0 2 % 2 + - / % 2 C4 +[...]
-
Page 38
36 5.8 CODABAR/N W7 Para meters A> Set Up Start/Stop Characters Upon T ra n smission ON <OFF> B> T ra n smission T ype of Start/Stop <A/B/C/D> <Start> <A/B/C/D> <Stop> A Start A Stop B Start B Stop C Start C Stop D Start D Stop % 0 J H1 % 0 J H0 % 0 4 V F % 0 4 F F % 0 4 V 1 % 0 4 F 1 % 0 4 V 2 % 0 4 F 2 % 0 4 V [...]
-
Page 39
37 C> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a [...]
-
Page 40
38 5.9 Code 93 Para meters A> Che ck Digit T ra n smission <Calculate Check 2 Digits & Not T ra n smit> Do Not Calculate Che ck Digit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the[...]
-
Page 41
39 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 K1 + % 4 K0 0 % 4 K0 0 % 4 K0 1 % 4 K0 2 % 2 + - / % 2 C6 +[...]
-
Page 42
40 5.10 Code 1 1 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Check 1 Digit & T ra n smit Calculate Che ck 1 Digit & Not T ra n smit Calculate Check 2 Digits & T ra n smit Calculate Che ck 2 Digits & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the &quo[...]
-
Page 43
41 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 L 1 + % 4 L 0 0 % 4 L 0 0 % 4 L 0 1 % 4 L 0 2 % 2 + - / % 2 C7 +[...]
-
Page 44
42 5.1 1 MSI/PLESSEY Code Para meters A> Che ck Digit T ra n smission Do Not Calculate Check Digit Calculate Che ck Digit & T ra n smit <Calculate Che ck Digit & Not T ra n smit> B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in [...]
-
Page 45
43 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 N1 + % 4 N0 0 % 4 N0 0 % 4 N0 1 % 4 N0 2 % 2 + - / % 2 C9 +[...]
-
Page 46
44 5.12 Code 2 of 6 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Check Digit & T ra n smit> Calculate Che ck Digit & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Ap[...]
-
Page 47
45 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 2 + - / % 4 P1 + % 4 P0 0 % 4 P0 1 % 4 P0 0 % 4 P0 2 % 2 CB+[...]
-
Page 48
46 5.13 LCD25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Che ck Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Setup Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, s[...]
-
Page 49
47 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2st Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 2 + - / % 4 Q 1 + % 4 Q 0 0 % 4 Q 0 1 % 4 Q 0 0 % 4 Q 0 2 % 2 CC +[...]
-
Page 50
48 5.14 T ele pen Para meters A> T ype of Code <Full ASCll Mode> % 0 T 8 0 Compre ssed Numeric Mode % 0 T 8 8 B> Che ck Digit T ra n smission Do Not Calculate Che ck Digit % 0 T N 3 Calculate Check Digit & T ra n smit <Calculate Che ck Digit & Not T ra n smit> % 0 T N 7 % 0 T N 5 C> Set Up Code Length T o set the f ixed[...]
-
Page 51
49 <V ari a ble> % 4 T 1 + Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 T 0 0 % 4 T 0 1 % 4 T 0 0 % 4 T 0 2 % 2 % + - / % 2 CF +[...]
-
Page 52
50 5.15 GS1 Databar(RSS Code) A> GS1 DataBar Omnidirectional ON <T ra n smit Che ck Digit> % 0 UN 7 Don't T ra n smit Che ck Digit % 0 UN 5 <T ra n smit Application ID> % 0 U8 8 Don't T ra n smit Application ID % 0 U8 0 T ra n smit Symbology ID % 0 U4 4 <Don't T ra n smit Symbology ID> % 0 U4 0 B> GS1 DataBar [...]
-
Page 53
51 <T ra n smit Application ID> % 0 V8 8 Don't T ra n smit Application ID % 0 V8 0 T ra n smit Symbology ID % 0 V4 4 <Don't T ra n smit Symbology ID> % 0 V4 0 C> GS1 DataBar Expa nded Para meters T ra n smit Symbology ID % 0 W 4 4 <Don't T ra n smit Symbology ID> % 0 W 4 0[...]
-
Page 54
52 Ch.6 M iscella neous Para meters 6.1 La nguage Sele ction <US English> UK English Itali a n Spa nish French Germa n Swedish Switzerla nd Hungari a n Ja pa ne se % 0 Z V0 % 0 Z V1 % 0 Z V2 % 0 Z V3 % 0 Z V4 % 0 Z V5 % 0 Z V6 % 0 Z V7 % 0 Z V8 % 0 Z V9[...]
-
Page 55
53 Belgium Portuguese Denmark Netherla nds T urkey Reserved2 % 0 Z VA % 0 Z VB % 0 Z VC % 0 Z VD % 0 Z VE % 0 Z VF[...]
-
Page 56
54 6.2 Bar Code ID ON <OFF> Default W ith this function ON, a le a ding chara cter will be a dded to the output string while sca nning code, user may refer to the following table to know what kind of bar code is be ing sca nned. Ple a se refer to the ta ble below f or matching code ID of codes read in. Code T ype ID Code T ype ID UPC-A A UPC-[...]
-
Page 57
55 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 9 1 A + % 9 1 B + % 9 1 Y + % 9 1 Z + % 9 1 E + % 9 1 F + % 9 1 G + % 9 1 H+ % 9 1 I + % 9 1 J + % 9 1 K + % 9 1 L + % 9 1 M + % 9 1 N+[...]
-
Page 58
56 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded Reserved5 Reserved6 % 9 1 P + % 9 1 R+ % 9 1 S + % 9 1 T + % 9 1 Q + % 9 1 U + % 9 1 V+ % 9 1 W +[...]
-
Page 59
57 6.3 Reading Level Bar Equals High <Bar Equals Low> 6.4 Accuracy <1 Time> 2 T i me s 3 T i me s 4 T i me s 6.5 Buzzer Bee p T one <High> Medium Low Off 6.6 LED Control(SV700 only) <ON> OFF % 0 1 3 0 % 0 1 3 1 % 0 1 3 2 % 0 1 3 3 % 0 1 J 3 % 0 1 J 2 % 0 1 J 1 % 0 1 J 0 % 0 3 I 0 % 0 3 I 2 % 0 9 O 8 % 0 9 O 0[...]
-
Page 60
58 6.7 Sensitivity of Continuous Read ing Mode A> Quick Setting: <Fa st> Slow B> Sa me Code Delay Re a ding Interval Following code sequences represent the length of ti me bef ore a barcode ca n be re sca nned at continuous a nd fla sh re a ding mode. The value ca n be def ined from 1-50 a nd they re pre sent 100ms to 5 se conds in 100m[...]
-
Page 61
59 6.9 Reverse Output Characters <Disable> % 0 3 H0 Enable 6.10 Setup Deletion T o setup the deletion of output chara cters: 1. Sca n the la bel of the de sired set below . 2. Sca n the la bel of the de sired symbology . 3. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the de sired position to be delete[...]
-
Page 62
60 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13/ISBN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 8 1 A + % 8 1 B + % 8 1 Y + % 8 1 Z + % 8 1 E + % 8 1 F + % 8 1 J + % 8 1 G + % 8 1 H+ % 8 1 I + % 8 1 K + % 8 1 L + % 8 1 M + % 8 1 N+[...]
-
Page 63
61 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded All Code s None C> Character Position to be Deleted 1. De ci mal V alue (Appendix A) 2. Complete D> Number of Chara cters to be Deleted 1. De ci mal V alue (Appendix A) 2. Complete % 8 1 P + % 8 1 S + % 8 2 0 + % 8 3 0 + % 8 1 4 + % 8 1 T + % 8 1 Q + % 8 1 U + % 8 1 V+ % 8 1 W +[...]
-
Page 64
62 6.1 1 Setup Insertion T o setup the in sertion of output chara cters: 1. Sca n the la bel of the de sired set. 2. Sca n the la bel of the de sired symbology . 3. Go to the De ci mal V alue T a ble s in Appendix A, sca n label(s) that represents the desired position to be inserted. 4. Sca n the "Complete" la bel of "Chara cter Posi[...]
-
Page 65
63 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13/ISBN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 5 1 A + % 5 1 B + % 5 1 Y + % 5 1 Z + % 5 1 E + % 5 1 F + % 5 1 G + % 5 1 J + % 5 1 H+ % 5 1 I + % 5 1 K + % 5 1 L + % 5 1 M + % 5 1 N+[...]
-
Page 66
64 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded All Code s None C> Character Position to be Inserted 1. De ci mal V alue (Appendix A) 2. Complete D> Characters to be Inserted 1. ASCII T a ble (Appendix B) 2. Complete % 5 2 0 + % 5 3 0 + % 5 1 4 + % 5 1 S + % 5 1 P+ % 5 1 T + % 5 1 Q + % 5 1 U + % 5 1 V+ % 5 1 W +[...]
-
Page 67
65 6.12 Setup IR Sensor (LG303 only) <Disable> Enable % 0 XH0 % 0 XH1[...]
-
Page 68
66 Appendix A De ci mal V alue T a ble 8 0 1 2 3 4 5 6 7 9[...]
-
Page 69
67 Appendix B ASCII T a ble NULL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 0 3 0 0 0 2 0 1 0 4 0 5 0 6 0 7 0 8 0 9 0A 0B 0C 0D 0E 0 F 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1A 1B 1C 1D 1E 1 F[...]
-
Page 70
68 SP ACE ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2A 2B 2C 2D 2E 2 F 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3A 3B 3C 3D 3E 3 F[...]
-
Page 71
69 @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4A 4B 4C 4E 4D 4 F 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5A 5B 5C 5D 5E 5 F[...]
-
Page 72
70 ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL 6 0 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 6A 6B 6C 6D 6E 6 F 7 0 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 7 9 7A 7B 7C 7D 7E 7 F[...]
-
Page 73
71 Appendix C Function Key T a ble F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F1 1 F12 Insert Delete Home Page Up Page Down End Left Right Up Down C 1 C 0 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C A C B C C C D C E C F D 0 D 1 D 2 D 3 D 4 D 5[...]
-
Page 74
%$ + / 0 %$ + / 1 %$ + / 2 %$ + / 3 %$ + / 4 %$ + / 6 %$ + / 5 Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Information Ver 3.8 a 0145-85E00J1[...]