Go to page of
Similar user manuals
-
Stereo Amplifier
Manley Labs 300B
12 pages 0.04 mb -
Stereo Amplifier
Manley Labs SE/PP 300B
11 pages 0.03 mb -
Stereo Amplifier
Manley Labs INTEGRATED AMPLIFIER
19 pages 0.08 mb -
Stereo Equalizer
Manley Labs STEREO EQ
34 pages 6.8 mb -
Power Supply
Manley Labs MANLEY REFERENCE DIGITAL TO ANALOGUE CONVERTER
11 pages 0.03 mb -
Stereo Amplifier
Manley Labs 500 / 200 WATT MONOBLOCK AMPLIFIER
13 pages 0.05 mb -
Stereo Amplifier
Manley Labs STEREO 75+75 WATT AMPLIFIER
12 pages 0.03 mb -
Stereo Receiver
Manley Labs MONOBLOCK AMPLIFIER
13 pages 0.04 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Manley Labs 300B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Manley Labs 300B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Manley Labs 300B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Manley Labs 300B should contain:
- informations concerning technical data of Manley Labs 300B
- name of the manufacturer and a year of construction of the Manley Labs 300B item
- rules of operation, control and maintenance of the Manley Labs 300B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Manley Labs 300B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Manley Labs 300B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Manley Labs service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Manley Labs 300B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Manley Labs 300B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MANLEY LABORA TORIES, INC. MANLEY LABORA TORIES, INC. 13880 MAGNOLIA A VE. CHINO, CA. 91710 TEL: (909) 627-4256 F AX: (909) 628-2482 OWNER'S MANUAL MANLEY NEO-CLASSIC SE / PP 300B AMPLIFIER[...]
-
Page 2
CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM 2 TOP PANEL 6 BIAS PROCEDURES 7 OPERATIONAL NOTES 8 SPECIFICATIONS 9 WARRANTY 10 WARRANTY REGISTRATION 11 SECTION PAGE[...]
-
Page 3
INTRODUCTION THANK YOU!... for choosing the Manley Neo-Classic SE / PP 300B Monoblock Amplifiers. The Manley Neo-Classic SE / PP 300B Amplifiers use only the best available components, with the shortest and cleanest signal path possible. These amps have the unique ability to switch from Single ended to Push-Pull topologies and the ability to adjust[...]
-
Page 4
READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE Pay special attention to pin Pay special attention to pin Pay special attention to pin Pay special a[...]
-
Page 5
MAINS CONNECTIONS Your amplifier has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not[...]
-
Page 6
CONNECTING YOUR AMPLIFIER Setting up your amplifiers is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier. 2. Connect the interconnects from the output of the preamplifier or switching center to the RCA input on the top rear of the amplifiers. 3. Connect the hot or "+" speaker cable [...]
-
Page 7
MANLEY SE / PP 300B TRIODE MONOBLOCK AMPLIFIER D E I H J Amplifier Overhead View A RCA Input Jack B Speaker Terminals C Mains input IEC/Switch module Mains fuse - Replace only with same type and value Power Switch D Tube 5U4 Rectifier E Tube 5U4 Rectifier F Power Tube 300B G Power Tube 300B H Bias trimmer ( for F & L ) I Bias trimmer ( for G &a[...]
-
Page 8
OPERATIONAL NOTES SWITCHING SINGLE-ENDED 11 / PUSH-PULL 24: This amplifier has the unique feature of being able to choose between two circuit topologies. You are able to switch between each mode while the amplifier is turned on and playing music. In SINGLE-ENDED mode the amplifier uses both 300Bs in parallel. The advantage is a minimalist circuit r[...]
-
Page 9
5.) The correct bias reading in "Single-Ended" mode is 550 mVDC. A reading of 540-560mVDC will be within specs. The bias in single-ended mode was set at the factory. If, however, the S-E bias reading is out of spec after warm up, the bias may be adjusted as follows: 6.) Carefully turn the amp on it's left side, Be sure to brace the a[...]
-
Page 10
SPECIFICATIONS Vacuum Tubes: 2 x 300B (Output), 1 x 6SN7 (Driver), 1 x 6SL7 (Input) 2 x 5U4 (Rectifier) Output Power @ 1Khz SINGLE-ENDED: 5 dB FB - 11 Watts @ 3% THD. PUSH-PULL: 5 dB FB - 24 Watts @ 1.5% THD. Frequency Response +/- .5 dB SINGLE-ENDED: 5 dB FB - 15 Hz - 15 Khz (measured at 5 watts) PUSH-PULL: 5 dB FB - 10 Hz - 20 Khz Input Sensitivi[...]
-
Page 11
W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year transferrable warranty is available upon proper registration of ownership within 30 days of date of first purchase. [...]
-
Page 12
W ARRANTY REGISTRA TION We ask, grovel and beg that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 USA Or you may FAX this form in to: +1 (909) 628-2482 or you may fill in the online warranty registration form found in the Tech Support section o[...]