Marley Engineered Products E4206-1125HFD manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Marley Engineered Products E4206-1125HFD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Marley Engineered Products E4206-1125HFD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Marley Engineered Products E4206-1125HFD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Marley Engineered Products E4206-1125HFD should contain:
- informations concerning technical data of Marley Engineered Products E4206-1125HFD
- name of the manufacturer and a year of construction of the Marley Engineered Products E4206-1125HFD item
- rules of operation, control and maintenance of the Marley Engineered Products E4206-1125HFD item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Marley Engineered Products E4206-1125HFD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Marley Engineered Products E4206-1125HFD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Marley Engineered Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Marley Engineered Products E4206-1125HFD.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Marley Engineered Products E4206-1125HFD item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Description Specifications and P erformance INST ALLA TION & OPERA TING INSTRUCTIONS & P ARTS MANUAL MODELS: E3606-1125HFD , E3609-1125HFD , E3612-1125HFD E3806-1125HFD , E3809-1125HFD , E3812-1125HFD E4206-1125HFD , E4209-1125HFD , E4212-1125HFD E4806-1125HFD , E4809-1125HFD, E4812-1125HFD E6006-2125HFD , E6009-2125HFD , E6012-2125HFD READ[...]

  • Page 2

    2 5. Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blower base. (See Figure 4.) Figure 4 - Removing Motor/Blo wer Assembly NOTE: Unit is shipped with styrofoam motor support block which must be discarded at this time. 6. T o remove motor/blower assembly , lift from rear of motor housing to prevent dam[...]

  • Page 3

    Installation 1. Using template provided, determine mounting location. 2. Drill holes and attach mounting hardware (not included). IMPORT ANT : THE HARD W ARE AND THE SUPPORTING STR UCTURE MUST BE CAP ABLE OF SUPPORTING A MINIMUM 150 LB. LO AD. NO TE: All installation should be done to meet local building code . 3. Mount cabinet on wall and securely[...]

  • Page 4

    Operation 1. After power has been connected to unit, fans will start in either preset (high/low) speed selection. 2. Air velocity is controlled by selection of high or low speed indicator . This feature allows the setting of air velocity to individual desired performance and energy efficiency . 3. Air direction at outlet can be controlled by adjust[...]

  • Page 5

    T roubleshooting Chart SYMPT OM POSSIBLE CA USE(S) CORRECTIVE A CTION Fan inoperative 1. Blown fuse or open circuit breaker . 2. Electricity turned off. 3. Loose cord connection. 4. Defective capacitor or motor . 1. Replace fuse or reset circuit breaker . 2. Contact local power company . 3. Re-check all connections. 4. Replace. 1. Center wheel. 2. [...]

  • Page 6

    Replacement P arts For Motor Blower Assemb lies (7) 6 Replacement P arts For Heater Units 1. 2 4 5 6 3 14 12 11 13 15 8 9 10 16 Replacement P arts For Air Curtain Cabinets 9 3 4 5 2 7 6 8 1D 1C 1B 1A Figure 8 - Replacement P ar ts.[...]

  • Page 7

    Replacement P arts List For Air Cur tain Cabinets Replacement P arts For 120 V olt Single Phase Motor Blower Assemb lies Replacement P arts List For Heater Units 7 REF . DESCRIPTION REPLA CEMENT P ARTS FOR 240V 1-PH HEA TERS NO . 6 KW 9 KW 10.8 KW QTY . 1 Wire Guards A. 18” APG0018 APG0018 APG0018 - B. 12” APG0012 APG0012 APG0012 - C. 6” APG0[...]

  • Page 8

    8 HO W T O ORDER REP AIR P ARTS In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center toll-free by calling 1-800- 642-HEA T . Part No. 5200-2418-001 03-02 ECR 35189 LIMITED W ARRANTY All products manufactured by Marley Engineered Products are wa[...]

  • Page 9

    Specifications and P erformance INST ALLA TION & OPERA TING INSTRUCTIONS & P ARTS MANUAL MODELS: E3606-1325HFD , E3609-1325HFD E3806-1325HFD , E3809-1325HFD E4206-1325HFD , E4209-1325HFD E4806-1325HFD , E4809-1325HFD E6006-2325HFD , E6009-2325HFD READ CAREFULL Y BEFORE A TTEMPTING T O ASSEMBLE, INST ALL, OPERA TE, OR MAINT AIN THE PRODUCT D[...]

  • Page 10

    5. Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blower base. (See Figure 4.) Figure 4 - Removing Motor/Blo wer Assembly NOTE: Unit is shipped with styrofoam motor support block which must be discarded at this time. 6. T o remove motor/blower assembly , lift from rear of motor housing to prevent damag[...]

  • Page 11

    Installation 1. Using template provided, determine mounting loca- tion. 2. Drill holes and attach mounting hardware (not includ- ed). IMPORT ANT : THE HARDW ARE AND THE SUPPORT - ING STRUCTURE MUST BE CAP ABLE OF SUPPORT - ING A MINIMUM 150 LB. LO AD. NO TE: All installation should be done to meet local building code. 3. Mount cabinet on wall and s[...]

  • Page 12

    Operation 1. After power has been connected to unit, fans will start in either preset (high/low) speed selection. 2. Air velocity is controlled by selection of high or low speed indicator . This feature allows the setting of air velocity to individual desired performance and energy efficiency . 3. Air direction at outlet can be controlled by adjust[...]

  • Page 13

    T roubleshooting Chart SYMPT OM POSSIBLE CA USE(S) CORRECTIVE A CTION Fan inoperative 1. Blown fuse or open circuit breaker . 2. Electricity turned off. 3. Loose cord connection. 4. Defective capacitor or motor . 1. Replace fuse or reset circuit breaker . 2. Contact local power company . 3. Re-check all connections. 4. Replace. 1. Center wheel. 2. [...]

  • Page 14

    6 Replacement P arts For Motor Blower Assemb lies (7) Replacement P arts For Heater Units 1. 2 4 5 6 3 14 12 11 13 15 8 9 10 16 Replacement P arts For Air Curtain Cabinets 9 3 4 5 2 7 6 8 1D 1C 1B 1A Figure 8 - Replacement P ar ts.[...]

  • Page 15

    7 Replacement P arts List For Air Cur tain Cabinets Replacement P arts For 120 V olt Single Phase Motor Blower Assemb lies Replacement P arts List For Heater Units REF . DESCRIPTION REPLA CEMENT P ARTS FOR 208V 3-PH HEA TERS NO . 6 KW 9 KW QTY . 1 Wire Guards A. 18” APG0018 APG0018 - B. 12” APG0012 APG0012 - C. 6” APG0006 APG0006 - D. 2” AP[...]

  • Page 16

    8 HO W T O ORDER REP AIR P ARTS In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center toll-free by calling 1-800-642-HEA T . Part No. 5200-2420-001 03-02 ECR 35189 LIMITED W ARRANTY All products manufactured by Marley Engineered Products are war[...]

  • Page 17

    REFER TO INDIVIDUAL MODEL NUMBERS FOR UNIT WIDTH 11 7 / 8 ” 3 1 / 4 ” 15 3 / 4 ” 12 1 / 2 ” Specifications and P erformance INST ALLA TION & OPERA TING INSTRUCTIONS & P ARTS MANUAL MODELS: E3606-1425HFD , E3609-1425HFD E3806-1425HFD , E3809-1425HFD E4206-1425HFD , E4209-1425HFD E4806-1425HFD , E4809-1425HFD E6006-2425HFD , E6009-242[...]

  • Page 18

    5. Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blower base. (See Figure 4.) Figure 4 - Removing Motor/Blo wer Assembly NOTE: Unit is shipped with styrofoam motor support block which must be discarded at this time. 6. T o remove motor/blower assembly , lift from rear of motor housing to prevent damag[...]

  • Page 19

    Installation 1. Using template provided, determine mounting loca- tion. 2. Drill holes and attach mounting hardware (not includ- ed). IMPORT ANT : THE HARDW ARE AND THE SUPPORT - ING STRUCTURE MUST BE CAP ABLE OF SUPPORT - ING A MINIMUM 150 LB. LO AD. NO TE: All installation should be done to meet local building code. 3. Mount cabinet on wall and s[...]

  • Page 20

    Operation 1. After power has been connected to unit, fans will start in either preset (high/low) speed selection. 2. Air velocity is controlled by selection of high or low speed indicator . This feature allows the setting of air velocity to individual desired performance and energy efficiency . 3. Air direction at outlet can be controlled by adjust[...]

  • Page 21

    T roubleshooting Chart SYMPT OM POSSIBLE CA USE(S) CORRECTIVE A CTION Fan inoperative 1. Blown fuse or open circuit breaker . 2. Electricity turned off. 3. Loose cord connection. 4. Defective capacitor or motor . 1. Replace fuse or reset circuit breaker . 2. Contact local power company . 3. Re-check all connections. 4. Replace. 1. Center wheel. 2. [...]

  • Page 22

    6 Replacement P arts For Motor Blower Assemb lies (7) Replacement P arts For Heater Units 1. 2 4 5 6 3 14 12 11 13 15 8 9 10 16 Replacement P arts For Air Curtain Cabinets 9 3 4 5 2 7 6 8 1D 1C 1B 1A Figure 8 - Replacement P ar ts.[...]

  • Page 23

    7 Replacement P arts List For Air Cur tain Cabinets Replacement P arts For 120 V olt Single Phase Motor Blower Assemb lies Key Part Numbers No. Description 1/4HP 7 Motor/Blower Assembly 120V 1-ph ACMB125 220V 1-ph ACMB225 208-230/460V 3-ph ACMB325 8 Switch plate cover ACFPSH 9 Rocker switch C1220 10 Cord, female plug ACW316 11 Motor Assembly 120V 1[...]

  • Page 24

    8 HO W T O ORDER REP AIR P ARTS In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center toll-free by calling 1-800-642-HEA T . Part No. 5200-2421-001 03-02 ECR 35189 LIMITED W ARRANTY All products manufactured by Marley Engineered Products are war[...]

  • Page 25

    REFER TO INDIVIDUAL MODEL NUMBERS FOR UNIT WIDTH 11 7 / 8 ” 3 1 / 4 ” 15 3 / 4 ” 12 1 / 2 ” Specifications and P erformance INST ALLA TION & OPERA TING INSTRUCTIONS & P ARTS MANUAL MODELS: E3606-1525HFD , E3609-1525HFD E3806-1525HFD , E3809-1525HFD E4206-1525HFD , E4209-1525HFD E4806-1525HFD , E4809-1525HFD E6006-2525HFD , E6009-252[...]

  • Page 26

    5. Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blower base. (See Figure 4.) Figure 4 - Removing Motor/Blo wer Assembly NOTE: Unit is shipped with styrofoam motor support block which must be discarded at this time. 6. T o remove motor/blower assembly , lift from rear of motor housing to prevent damag[...]

  • Page 27

    Installation 1. Using template provided, determine mounting location. 2. Drill holes and attach mounting hardware (not included). IMPORT ANT : THE HARDW ARE AND THE SUPPORT - ING STRUCTURE MUST BE CAP ABLE OF SUPPORT - ING A MINIMUM 150 LB. LO AD. NO TE: All installation should be done to meet local building code. 3. Mount cabinet on wall and secur[...]

  • Page 28

    Operation 1. After power has been connected to unit, fans will start in either preset (high/low) speed selection. 2. Air velocity is controlled by selection of high or low speed indicator . This feature allows the setting of air velocity to individual desired performance and energy efficiency . 3. Air direction at outlet can be controlled by adjust[...]

  • Page 29

    T roubleshooting Chart SYMPT OM POSSIBLE CA USE(S) CORRECTIVE A CTION Fan inoperative 1. Blown fuse or open circuit breaker . 2. Electricity turned off. 3. Loose cord connection. 4. Defective capacitor or motor . 1. Replace fuse or reset circuit breaker . 2. Contact local power company . 3. Re-check all connections. 4. Replace. 1. Center wheel. 2. [...]

  • Page 30

    Figure 8 - Replacement P ar ts. 6 Replacement P arts For Motor Blower Assemb lies (7) Replacement P arts For Heater Units 1. 2 4 5 6 3 14 12 11 13 16 8 9 10 15 Replacement P arts For Air Curtain Cabinets 9 3 4 5 2 7 6 8 1D 1C 1B 1A[...]

  • Page 31

    7 Replacement P arts List For Air Cur tain Cabinets Replacement P arts For 120 V olt Single Phase Motor Blower Assemb lies Key Part Numbers No. Description 1/4HP 7 Motor/Blower Assembly 120V 1-ph ACMB125 220V 1-ph ACMB225 208-230/460V 3-ph ACMB325 8 Switch plate cover ACFPSH 9 Rocker switch C1220 10 Cord, female plug ACW316 11 Motor Assembly 120V 1[...]

  • Page 32

    8 HO W T O ORDER REP AIR P ARTS In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center toll-free by calling 1-800-642-HEA T . Part No. 5200-2422-001 03-02 ECR 35189 LIMITED W ARRANTY All products manufactured by Marley Engineered Products are war[...]