Marquis DVT-38 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Marquis DVT-38, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Marquis DVT-38 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Marquis DVT-38. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Marquis DVT-38 should contain:
- informations concerning technical data of Marquis DVT-38
- name of the manufacturer and a year of construction of the Marquis DVT-38 item
- rules of operation, control and maintenance of the Marquis DVT-38 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Marquis DVT-38 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Marquis DVT-38, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Marquis service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Marquis DVT-38.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Marquis DVT-38 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MARQUIS 38 DVT-38 & DVR-38 Direct Vent Gas F ireplace 7116 Beat ty D r Missio n, BC V 2V 6B4 Canada For use with Natural Gas or Propane* Installer: Please leave this manual w ith the appliance owner for future reference 200-0044 MARCH 2005 *Conve rsi on Kit R equir ed f or Prop ane Use WA RNI NG: If the inf ormation in this manual is not follow[...]

  • Page 2

    [...]

  • Page 3

    Mar quis 38 3 CONTENTS Introduction 4 General Information 5 Appliance Description and Dimensions 6 Framing Dimensions 7 Clearance to Combustibles 8 Possible Fireplace Locations 9 Venting Instructions 10 - 13 Gas Connections 14 Glass Door Instructions 15 Log Placement Instructions 16 Fan and Valve Diagrams 17 Initial Start Up 18 - 19 Maintenance 20 [...]

  • Page 4

    Mar quis 38 4 INTRODUCTION Thank you for purchasing the Marquis DV-38 Direct Vent Built- in Gas Fireplace. The Marquis DV-38 is one of the most advanced gas fireplaces on the market. It is designed using the latest technology and manufactured to the highest quality. Some of the many features are: * Realistic Fire The Marquis DV-38 has a glowing emb[...]

  • Page 5

    Mar quis 38 5 GENERAL INFORMA TION This ap pliance is liste d by Warnock Her sey for use in both th e Unite d State s and Ca nada. I t is tested a nd certified to the following US and Canadian g as appliance stan dards. - ANSI Z21.50- 1996 / CGA 2.22-M 96, V ented G as Fire place a nd Heat ers - CAN/CGA-2.17-M91, Gas-Fired Appl ia nc e s fo r Us e [...]

  • Page 6

    Mar quis 38 6 APPLIANCE DESCRIPTION & DIMENSIONS GAS VALVE CONVECTION FAN SPEED CONTROL (Optional) TOP LOUVERS GLASS DOOR APPLIANC E DI MENSIONS FRONT VI EW 38” 23-1/2” 39-3/4” TOP VIEW SIDE VIEW FRONT VIEW 3” * Excep t for t he ven t conne ctor l ocatio ns, the r ear v ented D V-38 an d top ve nte d DVT -38, have the sa me ph ysic al d[...]

  • Page 7

    Mar quis 38 7 FRAMING DIMENSIONS FRAMING DIMENSIONS 38” 16- ¼ ” 38- ½ ” 26- ¼ ” 38” 54” TER MIN AT IO N FRAMING 11” 10” 38” *32- ¼ ” 16- ¼ ” 37” 12 ¾ ” 1 2 3 4 2” WHEN INSTALLING A SHELF OVER THE TOP OF REAR / TOP VENT MODEL DV38, THE F OLLOWING APPLIES: 1. Minim um height f r om flo or t o center of to p vent mu s[...]

  • Page 8

    Mar quis 38 8 CLEARANCE T O COMBUSTIBLES CLEARANCES TO COMBUSTIBLES BACK 0” to sta nd-of f s SID ES 0” to stand- off s TOP 0” to stand- off s BOTTO M 0” ADJACENT S IDE WALL 1” to si de of f acepla te MANTLE see d iag ram VENT 1” to outside side and bottom surface, 2” to outs ide top sur f ace. PRECAUTIONS • This appliance must be in[...]

  • Page 9

    Mar quis 38 9 B C F D E A A Cross Corner B Flush w ith Wa ll C Flat on W all Co rner D Flat on Wa ll E Is l a n d F Room Divi der 15 ft Max . 15 ft Max . POSSIBLE FIREPLACE LOCA TIONS LOCATING GAS FIREPLACE This app liance m ust be i nsta lled in any location that i s free of plumbing , electr ical wiri ng and h eating or air cond itioni ng duct s.[...]

  • Page 10

    Mar quis 38 10 VENTING INSTRUCTIONS VENTING The appliance will not function without being con nected to a proper venting s ystem. This appliance may use 4” and 7” gas flex vents with DV-38 listed vent componen ts, or Simpson Duravent 4 x 6-5/8 direct vent systems with Simpson Dura-ve n t Adaptor (SDA-3) . 7” dia. rig id ve nt may direc tly re[...]

  • Page 11

    Mar quis 38 11 VENTING INSTRUCTIONS Cont... • Chart is f or one 90° bend, with 1/4” vertical raise mi nimum per foot of horizontal length. • For each additional 90° or two 45° , add 1f t of vertical height. • Maximum two 90º bends, or equivalent. • Minimum 2 ft straight length between bends. Maintain a minimum of 1” clearance to com[...]

  • Page 12

    Mar quis 38 12 VENTING INSTRUCTIONS Cont... RESTRICTOR PLACEMENT “FOR ABOVE 7 FOOT VE RTICAL RISE VENTED APPLICATIONS ONLY” Vertical Venting Between Seven Feet (7’) an d Ten Feet (10’) must use Restrictor # 1. V ertical Venting Between Ten Feet (10’) and Twenty-four Feet (24’ ) for Rooftop Terminations m ust use Restrictor #2 . See Vent[...]

  • Page 13

    Mar quis 38 13 VENTING INSTRUCTIONS Cont... 24 Canadian Installations (1) US Installations (2) Canadian Installati ons (1) US Installations (2) A= Cl ear an ce a b ov e gr ad e, v era nd a , porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm) J= C lea ra nc e t o n on - m ech a ni ca l ai r supply inlet to building or th e combustion air in[...]

  • Page 14

    Mar quis 38 14 GAS CONNECTIONS Before co nnecting th e appliance to the gas su ppl y line, double check that the app liance y ou hav e purcha sed i s desi gned for t he gas type y ou are us i ng. The ga s type markings are locate d on the cer t ifica tion la bel a nd also on t he appl i ance ’s gas valve. Provid e adequate clea rance fo r prop er[...]

  • Page 15

    Mar quis 38 15 GLASS DOOR INSTRUCTIONS GLASS DOOR WARNING: Do not attempt to remove the glass door when the appliance is hot. Removing the Glass Door Remove the top and bottom louvers. There are two latches under the firebox. Undo the latches, swing the bottom of the door awa y from the appliance and then lift the door off the top retaining tabs. C[...]

  • Page 16

    Mar quis 38 16 LOG PLACEMENT INSTRUCTIONS PLACEMENT OF LOGSET, FIBER COALS & EMBER WOOL • Place the back log at the back of the burner tray as shown, behind the two tabs on the burner tray. • Place the front log on top of the burner as shown. The metal tabs protruding from the bottom of the log straddle the side of the burner top. • Place[...]

  • Page 17

    Mar quis 38 17 F AN & V AL VE WIRING DIAGRAM/INSTRUCTIONS ELEC TRICA L CONNEC TION S (for op tion al con vect ion fan kit FK 36 /38 on ly) • Install the fan first. Remove the lower louvers a nd gently place the bottom front lip of the blower mounting bracket into the opening. Slide the blower assem bl y into the bottom of the f ireplace. Rota[...]

  • Page 18

    Mar quis 38 18 INITIAL ST AR T UP INSTRUCTIONS FOR YOUR SAFETY, REA D BEFORE LIGH TING WARNING : If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. This appliance has a pilot which must be lit by hand using the sparker located next to the appliance valve control[...]

  • Page 19

    Mar quis 38 19 Set the thermostat, if present, to the lowest level. Press slightly and turn the control knob clockwise 3 to the OFF position and wait 5 minutes; thus allowing any gases to escape which may have accumulated in the combustion chamber. Note: LP gases do not vent upward. Then follow step 2 and 3 to establish pilot. INITIAL ST ART UP INS[...]

  • Page 20

    Mar quis 38 20 MAINTENANCE CAUTION : Only conduct m aintenance on a cold appliance. The exterior painted surfaces, glass and gold tr ims m a y be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner. Regularly, • Clean and remove any lint accumulations or debris from the grills and in any combustion and conv[...]

  • Page 21

    Mar quis 38 21 TROUBLESHOOTING SYMPTOM ACTION Pilot w ill not light after press ing the sparker man y times. 1. When lighting the appliance for the f irst time after installation or after servicing, there is air in the gas line. It takes a while for all the air to purg e out of the pi lot before gas can reach the pilot and ignite. Remove the glass [...]

  • Page 22

    Mar quis 38 22 TROUBLE SHOOTING Cont... SYMPTOM ACTION The main burn er does not turn on with the pilo t li t. Cont... 3. Check to make sure the th ermostat is set high enough to turn on the appliance. 4. Check that the remote switch or the thermostat is turned on. 5. Check for w eak pilot flame. If flame is weak, check g as suppl y, check pilot f [...]

  • Page 23

    Mar quis 38 23 SER VICING Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer where you purchased the appliance and provide them with details of the problem and the installa tion information which the installer filled out at the back of the manual. WARNING: Servi[...]

  • Page 24

    Mar quis 38 24 • Remove the bottom grill. • The pressure test taps are located on front of the valve. • The supply pressure is marked ‘ IN ’ and the manifold pressure is marked ‘ OUT ’. There is also an arrow marking the direction of gas flow. • Loosen the screw inside the tap with a 1/8” wide flat screw driver. • Connect a 1/4?[...]

  • Page 25

    Mar quis 38 25 SER VICING Cont... IF YOUR GLASS BREAKS CONVERTIBLE PILOT O RIFICE In the event your glass cracks or breaks, it must be replaced by the exact same size and material. It is made from high temperature cer amic material. See replacem ent parts list and contact your nearest Archgard dealer. • Remove door and carefully remove all traces[...]

  • Page 26

    Mar quis 38 26 • Disconnect power to the gas fireplace. • Remove the fan speed mounting bracket. • The convection blower is located at the bottom of the appliance at the back. Remove the three screws holding the blower. • Rotate the blower to the left and carefull y take the blower out with its back end out first. • Disconnect the wires f[...]

  • Page 27

    Mar quis 38 27 Parts can be ordered through your local dealer or distributor by giving IT EM # and DESCRIPTION. Item # Item Description Qty Unit 200-0044 OW NER’ S MANUAL, MARQU IS DV-38D & DVT38D 1 EA 301-0068 OR IFICE CAP, DRILL TO #56 (PROPANE GAS) 1 EA 301-0068 OR IFICE CAP, DRILL TO #48 (NATRAUL GAS) 1 EA 305-0013 FAN SPEED CONTROL (RHEO[...]

  • Page 28

    This Li mited Warrant y is made b y ARCHGARD INDUST RIES LTD., he re inafter referred to as “Archgard”. Archgard warrants to the ori ginal purchase r of an Arc hgard ga s b urning f i r eplace( s) that t he produc t will be fr ee from defe c ts in mater ia ls and w orkmans hi p under normal use an d service, for a “lifetime”. INCLU SI ONS: [...]

  • Page 29

    [...]

  • Page 30

    Postage WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6 B4 FOLD DO W N AT LI NE FOLD DOWN AT LINE & TAPE CLOSED CUT ALONG LI NE CUT ALON G LINE CUT ALONG LI NE Model # : Ser ial #: Date Inst alled: / / Name & Address: City : State/Prov: Phone: ( ______ ) Dealer's Nam e & Address: City : S[...]

  • Page 31

    Archgard Industries Ltd. 7116 Beatty Drive Mission, British Columbia, Canada V2V 6B4 Telephone: 604-820-8262 Telephone Toll Free: 877-820-9800 Fax: 604-820-8881 Fax Toll Free: 866-820-2802 Website: www.archgard.com[...]