A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of MaxTech V.34/V.42bis, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MaxTech V.34/V.42bis one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of MaxTech V.34/V.42bis. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of MaxTech V.34/V.42bis should contain:
- informations concerning technical data of MaxTech V.34/V.42bis
- name of the manufacturer and a year of construction of the MaxTech V.34/V.42bis item
- rules of operation, control and maintenance of the MaxTech V.34/V.42bis item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MaxTech V.34/V.42bis alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MaxTech V.34/V.42bis, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MaxTech service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MaxTech V.34/V.42bis.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the MaxTech V.34/V.42bis item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Part #MAN080 Rev. 1.0 S F-1128HV/R16-PnP High Performance V .34/V .42bis 28,800 BPS Internal Plug and Play F AX/V oice/Data Modem Featuring Advanced Full- Duplex Speakerphone Functions User's Manual[...]
-
Page 2
Contents Section One - Introduction ................................. 1 Section T wo - Installation .................................. 1 Section Three - A T Command Set .................... 7 Section Four - S Registers .............................. 13 Section Five - Result Codes ............................ 15 Section Six - Troubleshooting .......[...]
-
Page 3
1 Section One - Introduction This 28.8 Kbps Plug and Play FAX/Voice/Data Speakerphone Modem connects your computer to all popular high speed modems available today. Your new modem features advanced speakerphone functions for hands-free voice communication and is compatible with Plug and Play (PnP) systems for simplified installation and configurati[...]
-
Page 4
2 or, 2. If running DOS or Windows 3.x, configure the modem using the included modem driver. Instructions for installing this driver are included in the text file called README.1ST on the Windows 95 driver disk. The README.1ST file can be viewed by loading it into any wordprocessor or any text editor (i.e. DOS EDIT, NOTEPAD). It may also be viewed [...]
-
Page 5
3 6. Replace the computer cover and plug in your com- puter. 7. Connect the telephone cable from the modem's LINE connector to the telephone wall jack. See Figure 2-2. 8. Optionally, connect your telephone to the modem's PHONE connector. 9. Optionally, connect your microphone to the modem's MIC jack. 10. Optionally, connect your spea[...]
-
Page 6
4 The Install From Disk dialog box now instructs you to “Insert the manufacturer's installation disk into the drive selected, and then click OK.” Insert the modem's Utility diskette into the disk drive and type A: (or B: if inserted in drive B) in the “Copy manufacturer's files from:” box. Click “OK.” Windows 95 may req[...]
-
Page 7
5 MANAGER|MAIN|CONTROL PANEL , click on PORTS and follow Windows 3.1x user's manual instructions on configuring the installed modem COM port. Proceed to Section 2.5, Software Installation/Con- figuration. 2.5 Software Installation and Configuration You are now ready to install and configure the communication software. Refer to your software ma[...]
-
Page 8
6 2.7 Testing Your Modem After Installation In order to test your modem you should be familiar with your communication software. Load and set up your communication software and enter into “terminal mode.” Make sure that the COM Port and IRQ settings of the modem match the software. Type AT on your terminal screen and press ENTER . You may see ?[...]
-
Page 9
7 Section Three - AT Command Set 3.1 Executing Commands Commands are accepted by the modem while it is in Command Mode. Your modem is automatically in Command Mode until you dial a number and establish a connection. Commands may be sent to your modem from a PC running communication software or any other terminal devices. Your modem is capable of da[...]
-
Page 10
8 , pause @ wait for five seconds of silence ! flash ; return to Command Mode after dialing DS=n Dial one of the four telephone numbers (n=0-3) stored in the modem’s non-volatile memory. E_ E0 Commands are not echoed E1 Commands are echoed ++ + Escape Characters - Switch from Data Mode to Command Mode H_ H0 Force modem on-hook (hang up) H1 Force [...]
-
Page 11
9 W_ W0 Report DTE speed only W 1 Report line speed, error correction protocol, and DTE speed. W 2 Report DCE speed only X _ X 0 Hayes Smartmodem 300 compatible responses/blind dialing. X1 Same as X0 plus all CONNECT responses/ blind dialing X 2 Same as X1 plus dial tone detection X 3 Same as X1 plus busy detection/blind dialing X4 All responses an[...]
-
Page 12
10 ratio &P2 Same as &P0 setting but at 20 pulses per minute &P3 Same as &P1 setting but at 20 pulses per minute &R_ &R 0 Reserved & R 1 CTS operates per flow control requirements &S_ &S 0 Force DSR Signal High (ON) &S1 DSR off in command mode, on in on-line mode &T _ &T0 Ends test in progress &T1[...]
-
Page 13
11 d =300-28800. A, b, c, d default=11, 1, 300, 28800. Parameter “ a ” specifies the modulation protocol desired where: 0=V.21, 1=V.22, 2=V.22bis, 3=V.23, 9=V.32, 10=V.32bis, 11=V.34, 64=Bell 103, 69=Bell 212, and 74=VFC. Parameter “ b ” specifies automode operations where: 0=automode disabled, 1= automode enabled with V.8/V.32 Annex A. Par[...]
-
Page 14
12 N2 V.42 or MNP data link only N 3 V.42/MNP/Normal data link N4 V.42 data link only N5 MNP data link only 3.6 Fax Class 1 Commands +FAE=n Data/Fax Auto Answer +FCLASS=n Service Class +FRH=n Receive data with HDLC framing +FRM=n Receive data +FRS=n Receive silence +FTH=n Transmit data with HDLC framing +FTM=n Transmit data +FTS=n Stop transmis[...]
-
Page 15
13 +FPTS: Page Transfer Status +FPTS= Page Transfer Status +FREV? Identify Revision +FSPL Enable polling +FTSI: Report the Transmit Station ID 3.8 Voice Commands #BDR Select Baud Rate #CID Enable Caller ID detection and reporting format #CLS Select Data, Fax or Voice/Audio #MDL? Identify Model #MFR? Identify Manufacturer #REV? Identify Revision Lev[...]
-
Page 16
14 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255 /rings 0 S1 Ring counter 0-255 /rings 0 S2 Escape code character 0-127 /ASCII 43 S3 Carriage return character 0-127 /ASCII 13 S4 Line feed character 0-127 /ASCII 10 S5 Backspace character 0-32, 127 /ASCII 8 S6 Dial tone wait time 2-255 /seconds 2 S7 Remote ca[...]
-
Page 17
15 S49-81 Reserved S82 Break options 3, 7, or 128 128 S83-85 Reserved S86 Connection failure code 0, 4, 5, 9, 12, 13, 14 * S87-S90 Reserved S91 Transmit attenuation 0-15/dBm 10 S92 Fax attenuation 0-15/dBm 10 S95 Extended result code options Bit-mapped register Section Five - Result Codes OK 0 CONNECT 1 RING 2 NO CARRIER 3 ERROR 4 CONNECT 1200 5 NO[...]
-
Page 18
16 receive data from the modem. 2. Make sure that your modem is initialized correctly. Your modem may have been initialized to not display re- sponses. You may factory-reset the modem by issuing AT&F and press ENTER . The factory default allows the modem to display responses after a command has been executed. Modem does not dial. 1. Make sure t[...]
-
Page 19
17 communication software. 3. Make sure the data speed is not faster than your computer's capability. Most IBM compatibles are ca- pable of 19,200 bps under DOS and Windows. Operat- ing at higher speeds under Windows requires a faster CPU (386/486 or better), a high performance replace- ment Windows 3.1x comm.drv , or Windows 95. Modem experie[...]
-
Page 20
18 Data format: 300-115200 bps Power: 0.75 W Temperature: 0 to 55 degrees C (Operating) Caller ID: Y es PnP: Revision 1.0a Speakerphone: Full-duplex with DSP echo cancellation Appendix B - Speaker Type Selection Your modem supports both mono and stereo speakers. Use jumper JP3 to select the speaker type. The modem is factory set to use stereo speak[...]
-
Page 21
19 The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part 68, Sec. 68.381 (c) (3)). FCC Class B Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec- tion [...]
-
Page 22
20 company cause to request the user to disconnect the equip- ment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should[...]
-
Page 23
21[...]