Go to page of
Similar user manuals
-
Clothes Dryer
Maytag MD-1
48 pages 2.13 mb -
Clothes Dryer
Maytag PERFORMANCE W10260034A
24 pages 3.83 mb -
Clothes Dryer
Maytag Performance Series W10057353A
62 pages 3.43 mb -
Clothes Dryer
Maytag NEPTUNE MD98
72 pages 1.86 mb -
Clothes Dryer
Maytag W105623338C-SP
40 pages 6.71 mb -
Clothes Dryer
Maytag W10239207B
64 pages 3.06 mb -
Clothes Dryer
Maytag MDG51
26 pages 2.16 mb -
Clothes Dryer
Maytag MGD5830TW0
9 pages 0.78 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Maytag MDG30V, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Maytag MDG30V one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Maytag MDG30V. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Maytag MDG30V should contain:
- informations concerning technical data of Maytag MDG30V
- name of the manufacturer and a year of construction of the Maytag MDG30V item
- rules of operation, control and maintenance of the Maytag MDG30V item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Maytag MDG30V alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Maytag MDG30V, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Maytag service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Maytag MDG30V.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Maytag MDG30V item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MDG30V (30 lb. Single Pocket) Installation Manual 041202JEV/mcronan Part No. 113365 RET AIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. — Do not store or use gasol[...]
-
Page 2
Retain This Manual In A Safe Place For Futur e Refer ence This product embodies advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSER VE ALL SAFETY PRECAUTIONS displayed [...]
-
Page 3
CHILDREN SHOULD NOT BE ALLOWED T O PLA Y ON OR NEAR THE DR YERS. CHILDREN SHOULD BE SUPER VISED IF NEAR DRYER(S) IN OPERA TION. W ARNING DR YER(S) SHOULD NEVER BE LEFT UNA TTENDED WHILE IN OPERA TION. CAUTION FOR YOUR SAFETY DO NOT DR Y MOP HEADS IN THE DR YER. DO NOT USE DR YER IN THE PRESENCE OF DR Y CLEANING FUMES. “Caution: Label all wires pr[...]
-
Page 4
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels r emoved. PERSONAL INJUR Y OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/ or specified in the installation manual included with the dryer . Dryers must not be installed or stored in an area[...]
-
Page 5
Table of Contents SECTION I IMPOR T ANT INFORMA TION ............................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B . Safety Precautions ....................................................[...]
-
Page 6
SECTION VI ROUTINE MAINTENANCE .................................................................................. 3 5 A. Cleaning ................................................................................................................................... 35 B. Adjustments ......................................................................[...]
-
Page 7
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage [...]
-
Page 8
4 B. SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJUR Y OR FIRE COULD [...]
-
Page 9
5 W ARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard. W ARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. 7. A program should be e[...]
-
Page 10
6 SECTION II SPECIFICA TIONS A. SPECIFICA TIONS * MDG30V reversing dryer available with 3-phase (3ø) 1/2 HP (0.373 kw) motors standard. ** Size of piping to dryer varies with installation conditions. Contact factory for assistance. NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Gas[...]
-
Page 11
7 NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Specifications MDG30V[...]
-
Page 12
8 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LA TEST EDITION (National Fuel Gas Code) or ANSI/NFP A NO. 70-LA TEST EDITION (National Elect[...]
-
Page 13
9 B. LOCA TION REQUIREMENTS Before installing the dryer , be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LA TEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1- M91 (Na[...]
-
Page 14
10 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm) above the dryer ’ s outer top; except along the front of the dryer, which may be closed if desired. NOTE: Allowances must be made for opening the control door . NOTE: W ith the exception of [...]
-
Page 15
11 D. FRESH AIR SUPPL Y REQUIREMENTS The MDG30V air supply (make-up air) must be given careful consideration to assure proper performance of each dryer . An unrestricted source of air is necessary for each dryer . As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) is[...]
-
Page 16
12 E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of ener gy , and shutdown of the burner by the airflow (sail) switch, burner hi-limits, or lint chamber hi-limit protector thermostat. The[...]
-
Page 17
13 SINGLE DR YER VENTING IMPOR T ANT : For exhaust duct runs over 20 feet (6.1 meters) a minimum size of 10-inches (25.4 cm) must be used. HORIZONT A L VENTING When a single 8-inch (20.32 cm) horizontal vent is used, the ductwork to the outlet cannot exceed 20 feet (6.1 meters), refer to Illus. A below . This calculation of 20 feet (6.1 meters) com[...]
-
Page 18
14 VER TICAL VENTING When vertical single 10-inch (25.4 cm) venting is used (refer to Illus. B below ), the ductwork from the dryer to the outside outlet cannot exceed 40 feet (12.19 meters). This calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating the 180° (turned downward) outside outlet. Il[...]
-
Page 19
15 MUL TIPLE DR YER (COMMON) VENTING If it is not feasible to provide separate exhaust ducts for each dryer , ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper . The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of[...]
-
Page 20
16 HORIZONT A L VENTING Illus. C VER TICAL VENTING Illus. D[...]
-
Page 21
17 IMPOR T ANT VENTING REMINDERS 1. Ductwork size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible. 4. A void 90° turns, use 30° or 45° turns instead. Long radius turns after less resistance[...]
-
Page 22
18 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials,[...]
-
Page 23
19 NOTE: Component failure due to improper voltage application will VOID THE W ARRANTY . 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO. 70-LA TEST EDITION,[...]
-
Page 24
20 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer . SI N GLE - PHA SE ( 1Ø) ELEC TRI [...]
-
Page 25
21 5. 3-Phase (3ø) W iring Connections/Hookup The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes Neutral) and ground. Single-phase (1ø) power for the control circuit is done internally to the dryer . No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer . IMPOR T A[...]
-
Page 26
22 IMPOR T ANT : Figures shown are for non-reversing models only . For reversing models contact the factory . IMPOR T ANT : The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel area behind the top control (access) door . In the case of 208 V AC or 240 V AC, the supply voltage must match t[...]
-
Page 27
23 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requireme[...]
-
Page 28
24 2. T echnical Gas Data a . Gas Specifications *Measured at outlet side of gas valve pressure tap when gas valve is on. b. Gas Connections Inlet connection ------------- 1/2” N.P .T . Inlet supply size ------------- 1/2” N.P .T . (minimum) Heat input (per dryer) ------ 100,000 btu/hr (25,200 kcal/hr) 1) Natural Gas Regulation is controlled by[...]
-
Page 29
25 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P .] Gas) or LA TEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done [...]
-
Page 30
26 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W .C.) pre[...]
-
Page 31
27 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ W ARNING ,” and “ DIRECTION ” labels attached to the dryer . 2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the left side[...]
-
Page 32
28 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory . However , a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1. T urn on electric power to the dryer . 2. Ref[...]
-
Page 33
29 5. Make a complete operational check of ALL operating controls. NOTE: If computer program changes are required, refer to the computer programming section of the manual supplied with the dryer . 6. The dryer should be operated through one (1) complete cycle to assure that no further adjustments are necessary and that ALL components are functionin[...]
-
Page 34
30 NOTES: 1 . If the Anti-Wrinkle program is active, the light emitting diode (L.E.D.) display will continue to read “donE,” and the microprocessor controller (computer) will proceed through the Anti-W rinkle program until the maximum “Active Guard T ime” has expired or until the door is opened, whichever comes first. The L.E.D. display wil[...]
-
Page 35
31 IMPOR T ANT : If the door is opened during a cycle, both the heat and motor will stop. However , the microprocessor controller (computer) will continue to count the time, either upward or downward, depending on which parameter is programmed. Continuation of the cycle will resume only after the door has been closed and any other of the three (3) [...]
-
Page 36
32 K . SHUT DOWN INSTRUCTIONS If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker . 2. Discontinue the heat supply: a. GAS MODELS ...discontinue the gas supply . 1) SHUT OFF external gas supply [...]
-
Page 37
33 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency , or gas supplier . If service is required, contact the dealer from whom the Maytag equipment was purchased. If the dealer cannot be contacted or is unknown, contact the Maytag Co. for a dealer in your area. NOTE: W[...]
-
Page 38
34 SECTION V W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the manufacturer’ s test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should y[...]
-
Page 39
35 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent[...]
-
Page 40
36 90 DA YS Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer ’ s internal exhaust ducting. W ARNING: THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD. W ARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILA TION AIR. W ARNING: INSPECT AND REMOVE ANY LINT AC[...]
-
Page 41
37 D. LINT DRA WER REMOV AL T o remove the lint drawer from the dryer pull drawer out approximately halfway . Rotate/move lint drawer stop hinge (refer to the illustration below ) downward and pull the drawer out. IMPOR T ANT : After replacing the lint drawer back into the dryer , be sure to rotate/move hinge back to the upward stop position.[...]
-
Page 42
38 SECTION VII TROUBLESHOOTING IMPOR T ANT : YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS. The information pro[...]
-
Page 43
39 4. Failed microprocessor controller (computer). C. Drive motor (r eversing) operates in one (1) direction only ...stops and restarts in same direction... 1. Failed drive motor contactor (relay). 2. Failed arc suppressor (A.S.) board (for reversing models only). 3. Failed microprocessor controller (computer). D . Drive motor operates okay for a f[...]
-
Page 44
40 3. Failed arc suppressor (A.S.) board (for reversing models only). 4. Failed microprocessor controller (computer). 5. Failed 24 V AC transformer . H. Both drive motor and blower motor run a few minutes and then stop...microprocessor controller (computer) display continues to r ead time or per cent of extraction and ALL indicator dots are off... [...]
-
Page 45
41 M . Microprocessor controller (computer) locks up and the light emitting diode (L.E.D.) display reads erroneous message(s) or only partial segments... 1. T ransient power voltage (spikes)...disconnect power to dryer , wait 1 minute, and reestablish power to dryer . If problem is still evident... a . Failed microprocessor controller (computer). b[...]
-
Page 46
42 3. Fault in lint chamber sensor bracket or tripped manual reset hi-heat limit protector thermostat. 4. Failed Direct Spark Ignition (DSI) module. 5. Failed DSI ignitor/flame-probe assembly . 6. Failed microprocessor controller (computer). Q . Dryer operates but is taking too long to dry ... 1. Exhaust ductwork run too long or is undersized...bac[...]
-
Page 47
43 b. Check gap between front panel and basket (tumbler)...setscrews may have come loose and basket (tumbler) walked forward or backwards. 3. Loose basket (tumbler) tie rod. 4. Failed basket (tumbler) support. T . Excessive noise and/or vibration... 1. Dryer is not leveled properly . 2. Impellor (fan/blower) is out of balance... a . Excessive lint [...]
-
Page 48
44 SECTION VIII DA T A LABEL INFORMA TION A. DA T A LABEL When contacting the Maytag dealer certain information is required to insure proper service/parts information. This information is on the data label af fixed to the left side panel area behind the top control (access) door . When contacting the Maytag Co. please have the model number and seri[...]
-
Page 49
45 THE DA T A LABEL 1. MODEL NUMBER The model number is an Maytag Company number , which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows Maytag to gather information on your particular dryer . 3. MANUF ACTURING CODE NUMBER The manufacturing code number is a number issued by M[...]
-
Page 50
46 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer . b. Start the drying cycle. c . V erify that the motor(s) and the heat indicator dots, in the microproces[...]
-
Page 51
47 e . Open main door . The dryer must stop and ALL output indicator lights on the back side of the microprocessor controller (computer) board must go out. (Refer to the illustration on the previous page.) f . T ry to restart the dryer with the main door open. g. The microprocessor controller (computer) board’ s light emitting diode (L.E.D.) disp[...]
-
Page 52
113365 1 - 04/22/02-25[...]