METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 should contain:
- informations concerning technical data of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34
- name of the manufacturer and a year of construction of the METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 item
- rules of operation, control and maintenance of the METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the METRObility Optical Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation & User Guide Models: R125-34 / R125-37 / R135-34 R ADIANCE SONET S INGLE I NTERF ACE L INE C ARDS PWR OC-3 M M L H R X LK LK R X T X T X PWR M M OC-12 S M R X LK LK R X T X T X PWR OC-3 M M S M R X LK LK R X T X T X[...]

  • Page 2

    This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or oth[...]

  • Page 3

    T able of Contents Radiance SONET Single Interface Line Cards Installation & User Guide Overview ............................................................................................................. 4 Installation Guide ............................................................................................... 5 STEP 1: Unpack the L[...]

  • Page 4

    4 Overview The Radiance SONET single interface line card pr ovides seamless integration between fiber optic multimode and singlemode segments in OC-3/ STM-1 or OC-12/STM-4 networks. Use the card’ s singlemode connector to extend your network reach up to 40 km. The Radiance line card is manageable through console commands, Metrobility’ s GUI-bas[...]

  • Page 5

    Radiance SONET Single Interface Line Cards 5 Installation Guide Follow the simple steps outlined in this section to install and start using your Radiance SONET single interface line card. NOTE: Electr ostatic dischar ge pr ecautions should be taken when handling any line car d. Pr oper gr ounding is r ecommended (i.e., wear a wrist strap). Unpack t[...]

  • Page 6

    6 Installation Guide Link Loss Return Switches The Radiance SONET single interface line card incorporates Link Loss Return (LLR) functionality as an aid in troubleshooting remote connections. LLR is enabled independently on each port. When LLR is enabled on a port, loss of its receive (RX) link disables its own transmit (TX) link. LLR1 enables/disa[...]

  • Page 7

    Radiance SONET Single Interface Line Cards 7 Install the Line Card The Radiance SONET single interface line card offers the ease of plug- and-play installation and is hot-swappable. All cards must be firmly secured to the chassis before network connections are made. Follow the simple steps outlined below to install your line card. • Grasp the car[...]

  • Page 8

    8 Installation Guide Connect to the Network T o connect the Radiance line card to the network, insert the fiber optic cables into the appropriate SC connectors. (See the figure below .) Be sure the card is secured to the chassis before making network connec- tions. When making network connections, make sure that the transmit (TX) optical conductor [...]

  • Page 9

    Radiance SONET Single Interface Line Cards 9 User Guide This section contains more information r egarding the operating features of the Radiance SONET single interface line card. LED Indicators The Radiance SONET single interface line card provides three LEDs on the front panel for the visible verification of unit status and proper functionality . [...]

  • Page 10

    10 User Guide Link Loss Return (LLR) Both ports on the Radiance SONET single interface line card have been de- signed with LLR for troubleshooting a remote connection. When LLR is enabled * , the port’ s transmitter shuts down if its receiver fails to detect a valid receive link. LLR should only be enabled on one end of a cable and is typically e[...]

  • Page 11

    Radiance SONET Single Interface Line Cards 11 Link Loss Carry Forward (LLCF) The Radiance SONET single interface line card incorporates LLCF for trouble- shooting a remote connection. W ith LLCF , the ports do not transmit a signal until they receive a signal from the opposite port. For example, if a line card loses link on Port 2, the card will no[...]

  • Page 12

    12 User Guide T opology Solutions Enterprise Switch Workgroup Hub Singlemode Links Multimode Links Switch Switch PC running Network Management Software Servers Enterprise Radiance R5000 Central Service Platform with SONET Single Interface Line Cards remote connection — singlemode[...]

  • Page 13

    Radiance SONET Single Interface Line Cards 13 Data Rate Data Rate _____________ 155Mbps (OC-3/STM-1), 622Mbps (OC12/STM-4) Power Consumption Input ______________________________________________ 5V @ 0.8A, 4W Environmental Operating T emperature ____________________________________ 0 ° to 50 ° C Storage T emperature _______________________________[...]

  • Page 14

    14 User Guide Product Safety , EMC and Compliance Statements This equipment complies with the following requirements: •U L • CSA • EN60950 (safety) • FCC Part 15, Class A • EN55022 Class A (emissions) • EN50082-1 (immunity) • IEC 825-1 Classification • Class 1 Laser Product • DOC Class A (emissions) This product shall be handled, [...]

  • Page 15

    Radiance SONET Single Interface Line Cards 15 W arranty and Servicing Three-Y ear W arranty for Radiance SONET Single Interface Line Card Metrobility Optical Systems, Inc. warrants that every Radiance SONET single interface line card will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipm[...]

  • Page 16

    Product Manuals The most recent version of this manual is available online at http://www .metrobility .com/support/manuals.htm Product Registration T o register your product, go to http://www .metrobility .com/support/registration.asp 25 Manchester Street, Merrimack, NH 03054 USA tel: 1.603.880.1833 • fax: 1.603.594.2887 www .metrobility .com 566[...]