Go to page of
Similar user manuals
-
Scanner
Metrologic MS7600
60 pages 4.61 mb -
Scanner
Metrologic Hand-Held Scanner
13 pages 0.22 mb -
Scanner
Metrologic MS951
77 pages 0.21 mb -
Scanner
Metrologic MS9500 Voyager
56 pages 2.3 mb -
Scanner
Metrologic FocusBT MS1633
2 pages 0.64 mb -
Scanner
Metrologic MS770
27 pages 0.27 mb -
Scanner
Metrologic MS6130 MX003
44 pages 0.31 mb -
Scanner
Metrologic TECH 8
20 pages 0.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Metrologic Hand-Held Scanner, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Metrologic Hand-Held Scanner one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Metrologic Hand-Held Scanner. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Metrologic Hand-Held Scanner should contain:
- informations concerning technical data of Metrologic Hand-Held Scanner
- name of the manufacturer and a year of construction of the Metrologic Hand-Held Scanner item
- rules of operation, control and maintenance of the Metrologic Hand-Held Scanner item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Metrologic Hand-Held Scanner alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Metrologic Hand-Held Scanner, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Metrologic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Metrologic Hand-Held Scanner.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Metrologic Hand-Held Scanner item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PULSAR C CCD Hand-Held Scanner User Manual Metrologic Instruments GmbH Dornier S trasse 2 82178 Puchheim Germany T el +49 89 890190 Fax +49 89 89019200 www .europe.metrologic.com © Metrologic Instruments Eur ope, 2001. All rights reserved WARNING This equipment has been tested and found to comply with the limits for a Class A digital device, pursu[...]
-
Page 2
Table of Contents 1. Introduc tion .................................................................................. 1 2. General Featur es ......................................................................... 2 2.1 Buzze r .................................................................................... 2 2.2 Indica tor ...................[...]
-
Page 3
1 1. Introduction This manual contains all the info rmation needed to operate and configure the Pulsar C Barcode Scanner. It is divi ded into two parts. The first part of this manual describes the operation and programmable features of the scanner. The second part of this manual contains the setup barcodes used to configure the scanner. The Pulsar [...]
-
Page 4
3 period ( Scanner Time-Out Duration ) is expired. Unlike the Auto Off mode, the scanner will continue to scan and the scanning period is re-counted each time there is a successful read. • Alternate Mode: The scanner will start scanning once the switch is triggered. The scanner will continue scanning until the switch is triggered again. • Momen[...]
-
Page 5
5 3. Output Interface The Pulsar C is a single interface CCD scanner. It can be ordered as a keyboard wedge scanner, and a RS-232 scanner. The output interface must be specified at time of order. 3.1 Keyboard Wedge Interface 3.1.1 Keyboard Type The keyboard wedge interface is enabled by configuring/selecting keyboard type. The supported keyboard ty[...]
-
Page 6
7 3.2 RS232 Interface The user can select the desired, fl ow control, baud rate, parity, and data bits to be used in this output interface. 3.2.1 Baud Rate / Parity / Data Bits The supported baud rate, parity, and data bit are listed below. • Baud Rate : 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 600 / 300 • Parity : None / Even / Odd • Data[...]
-
Page 7
9 kind of undesired reading, the Code Length settings can help to insure that the correct code is read by qualifying the allowable code length. Code length parameters can be configured in two ways: Fixed Code Length or Max / Min code length . If the fixed code length is selected, up to 2 fixed lengt hs can be specified. And if max / min code length[...]
-
Page 8
11 and Max/Min code length . If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the mi n length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified. 4.10 Plessey • Convert to UK Plessey : If this[...]
-
Page 9
13 5.3 Code ID Up to two characters of Code ID c an be configured for each symbology. To minimize the Code ID configuration efforts, the scanner provides five predefined Code ID Sets that user can se lect from. User can first select one of the Code ID Sets and then make desired modifications. The pre-defined Code ID Sets are shown below. Set 1 Set [...]
-
Page 10
15 • Code Type : This parameter specifie s the code type of the data eligible for data editing. Multiple code types can be specified for this parameter. • Data Length : This parameter specifies the length (character count) of the data eligible for data editing. It is specified in the range format. The length of the data must fall between max an[...]
-
Page 11
17 Example 2: Extract the date code, item number, and quantity information from barcodes. Data is encoded in t he barcode like this: From the first character to the 6th character is the date code. From the 7th character is the item number, its length is not fixed but is delimited by a ‘-’ character. After the ‘-’ character is the quantity i[...]
-
Page 12
19 For these kinds of parameters, the l abel of the parameter to be configured must be read first. Then the labels comprising the numeric value or character string are read. Finally, t he “Validate” label must be read to complete the setting. The scanner will respond with two beeps when the “Validate” label is read. 7.4.1 Numeric Parameters[...]
-
Page 13
21 • Add Control (R) : The right Control key will be sent together with the character programmed. • Add Alternate (R) : The right Alternate key will be sent together with the character programmed. For example, to program the Prefix Code to be “Ctrl-Shift-B”, “C”, the programming sequence should be: 1) “Prefix Code” label 2) “Add C[...]