MGE UPS Systems 2200 RT 2U manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems 2200 RT 2U, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems 2200 RT 2U one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems 2200 RT 2U. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of MGE UPS Systems 2200 RT 2U should contain:
- informations concerning technical data of MGE UPS Systems 2200 RT 2U
- name of the manufacturer and a year of construction of the MGE UPS Systems 2200 RT 2U item
- rules of operation, control and maintenance of the MGE UPS Systems 2200 RT 2U item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems 2200 RT 2U alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems 2200 RT 2U, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems 2200 RT 2U.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems 2200 RT 2U item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    34003641FR/ AA - Page 1 T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R www.mgeups.com Installation and user manual Pulsar M 2200 RT 2U 2200 RT 3U 3000 RT 2U 3000 RT 3U 3000 RT 3U XL EXB RT 3U[...]

  • Page 2

    34007776EN /AB - Page 2[...]

  • Page 3

    34007776E N/AB - Page 3 Introduction Environmental protection MGE UPS SYSTEMS has implemented an environmental-protection policy. Products are developed accordi ng to an eco-design approach. Subst ances This product does not contain CFCs, HCFCs or asbestos. Packing To improve waste treatment and facilitate re cycling, separate the various packing c[...]

  • Page 4

    34007776EN /AB - Page 4 Introduction Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio signal. In the illustrations on the follow ing pages, the symbols below are used: LED off LED on LED flashing[...]

  • Page 5

    34007776E N/AB - Page 5 Contents 1. Present ation 1.1 St andard positions ..... .............. .............. ................ .............. .............. ............... .............. ............ 6 T ower position ............ .............. .............. ................. .............. .............. .............. .............. ..........[...]

  • Page 6

    34007776EN /AB - Page 6 1. Presentation 1.1 Standard positions Tower position Rack position Dimensions (H x W x D) in mm Pulsar M 2200 RT 2U 440 x 86 x 640 Pulsar M 2200 RT 3U 440 x 131 x 490 Pulsar M 3000 RT 2U 440 x 86 x 640 Pulsar M 3000 RT 3U 440 x 131 x 490 Pulsar M 3000 RT 3U XL 440 x 131 x 490 Pulsar M EXB RT 3U 440 x 131 x 490 Weights in kg[...]

  • Page 7

    34007776E N/AB - Page 7 1. Presentation 1.2 Rear panels Pulsar M 2200 / 3000 Pulsar M EXB (optional battery module) 1.3 Control panel (1) USB co mmunicat ion por t (2) RS232 communication port (3) Connector for automatic recognition of an additional battery module (4) Slot for optional communication card (5) Connector for remote ON/OFF and RPO (Rem[...]

  • Page 8

    34007776EN /AB - Page 8 2. Installation 2.1 Unpacking and contents check (30) Pulsar M 2200 or 3000 UPS (31) connection cable to AC-power source (32) 2 connection cables fo r the protected equipment (33) RS232 communications cable (34) USB communications cable (35) 2 systems to secure power plugs (36) Solution-Pac CD-ROM (37) Documentation Elements[...]

  • Page 9

    34007776E N/AB - Page 9 2. Installation 2.2 Installation in tower position 2.3 Installation in rack position It is advised to first install the battery module , then the power module above . Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware are supplied by MGE UPS SYSTEMS. 1 2 3 1 2 3 3 2 4 2 4 1 1 1 1[...]

  • Page 10

    34007776EN /AB - Page 10 2. Installation 2.4 Communication ports Connection of RS232 or USB communication port (optional) Installation of the communication cards (optional) The RS232 and USB commun ication ports cannot operate simultan eously. 1 - Connect the RS232 (33) or USB (34) communication cable to the serial or USB port on the computer equip[...]

  • Page 11

    34007776EN /AB - Page 11 2. Installation 2.5 Connections with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connections with a HotSwap MBP module (optional) The HotSwap MBP module makes it possible to serv ice or even replace the UPS wit hout affecting the connected loads ( HotSwap function). 1 - Connect the UPS socket (10) to the AC- p[...]

  • Page 12

    34007776EN /AB - Page 12 2. Installation HotSwap MBP-module operation UPS st art-up with th e HotSwap MBP module 1 - Check that the UPS is correctly connected to the Hot Swap MBP module. 2 - Set switch (53) to the Normal po sition. 3 - Start the UPS by pressing the ON/OFF button (27) on the UPS control panel. The load is supplied by the UPS. LED (5[...]

  • Page 13

    34007776EN /AB - Page 13 3. Operation 3.1 Start-up and norm al operation UPS personalisa tion 3.2 Operation on battery power T ransfer to battery power Low-battery warning For the initial start, AC power must be present to detect any wiring e rrors. Subsequently, the UPS can start even if AC power is not present. Press button (27) for approximately[...]

  • Page 14

    34007776EN /AB - Page 14 3. Operation End of battery backup time 3.3 Return of AC power Following an outage, the UPS restarts auto matically when AC power retu rns (unless the restart f unction was disabled via UPS personalisation) and t he load is again supplied. 3.4 UPS shutdown 3.5 Using the UPS remo te control functions Pulsar has the choice of[...]

  • Page 15

    34007776EN /AB - Page 15 3. Operation Contact open: shut down of UPS Contact closed: start-up of UPS (UPS connected to the network and network energized) Note: local On/Off control via button (27) has priority over the remote control order. Contact open: shut down of UPS T o return to normal operation, dea ctivate the external remote shut down cont[...]

  • Page 16

    34007776EN /AB - Page 16 4. Access to measurements and personalisation data 4.1 Display menus arrangement 4.2 Access to measurements Press the scroll button (25) to access any status conditions a nd alar ms, then the measurements for voltage, current, frequency, power output and battery backup time. 4.3 Personalisation using the control pa nel Loca[...]

  • Page 17

    34007776EN /AB - Page 17 4. Access to measurements and personalisation data Output personalisation (1) These parameters may be modified only when the UPS is OFF. Detailed comments are available in the Persona l Solution-Pac software. ON/OFF personalisati on Battery personal isation 4.4 Personalisation us ing external software Function Factory setti[...]

  • Page 18

    34007776EN /AB - Page 18 5. Maintenance 5.1 Troubleshooting If LED (21) or (22) is ON, a fault or an alarm has occurred. Use the escape button (24) to stop the audio alarm. Indication Diagnostic C orrection 1 The UPS does not start, the alphanumeric display indicates: COLD START NOK CHECK AC WIRING The AC input power is not connected or is conne ct[...]

  • Page 19

    34007776EN /AB - Page 19 5. Maintenance Troubleshooting a UPS equipped with the HotSwap MBP module 5.2 Battery-module replacement Safety recommendations The battery can cause electrocutio n and high short-circuit currents. T he following safety cautions are requi red before servicing the battery comp onents: ◗ Remove watches, rings, bracelets and[...]

  • Page 20

    34007776EN /AB - Page 20 5. Maintenance Mounting the new battery module Carry out the above instruct ions in reverse order. 5.3 Maintenance on a UPS equippe d with the HotSwap MBP module D - Remove the metal protection cover in front of the battery (two screws). E - Pull the plastic tab to remove the battery block and replace it. ◗ To ensure safe[...]

  • Page 21

    34007776EN /AB - Page 21 5. Maintenance 5.4 Training centre To fully master operation of your MG E UPS SYSTEMS product and carry out level 1 servicing, see our complete range of technical training courses, avai lable in both French and English. 50 Hz training centre MGE UP S SYST EMS 140 avenue Jean-Kuntzmann Zirst - Montbonnot St-Martin 38334 St-I[...]

  • Page 22

    34007776EN /AB - Page 22 6. Appendices 6.1 Technical specifications (1) Depending on the output voltage selected: 200V / 2 08V / 220V / 230V / 240V, the output power is 1980VA / 1980VA / 2200VA / 2200VA / 2200VA. (2) Depending on the output voltage selected: 200V / 2 08V / 220V / 230V / 240V, the output power is 2700VA / 2700VA / 3000VA / 3000VA / [...]

  • Page 23

    34007776EN /AB - Page 23 6. Appendices 6.2 Glossary Bypass AC input Bypass line from the AC-power sour ce, controlled b y the UPS, used to directly supply the load if an overload or a malfunction occurs on the UPS. Backup time T ime during which t he load can be supplied by the UPS operating on battery power . Battery test Internal UPS test to chec[...]

  • Page 24

    34007776EN /AB MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140, Avenue Jean Kuntzmann ZIRST - M ontbonno t St Martin 38334 - Saint Ismier Cedex - Fr ance www.mgeups.com[...]