MGE UPS Systems 3200RT manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems 3200RT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems 3200RT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems 3200RT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of MGE UPS Systems 3200RT should contain:
- informations concerning technical data of MGE UPS Systems 3200RT
- name of the manufacturer and a year of construction of the MGE UPS Systems 3200RT item
- rules of operation, control and maintenance of the MGE UPS Systems 3200RT item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems 3200RT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems 3200RT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems 3200RT.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems 3200RT item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    www.mgeups.com Pulsar EX 2200RT / 3200R T EXB 2200/3200 RT Installation and User Manual MGE UPS SYSTEMS,INC.[...]

  • Page 2

    SA VE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS, Inc. product to protect your electrical equipment. The Pulsar EX RT range has been designed with the utmost care. We recommend that you take the time [...]

  • Page 3

    3400753300/AE - Page 3 CAUTION: Safety of persons ◗ The UPS has its own internal power source (the battery). Consequently , the power outlets may be energized even if the UPS is disconnected from the AC-power source. ◗ Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. ◗ The UP[...]

  • Page 4

    Page 4 - 3400753300/AE Using this document How to use this document Icon Usage Information may be found primarily by consulting: ◗ The contents, ◗ The index. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Audio indication. Action. V isual indication. Notes, tips and information, help. CAU[...]

  • Page 5

    3400753300/AE - Page 5 1. Presentation 1.1 System configurations ....................................................................................................... ......... 7 Rack setup ......................................................................................................................................7 T ower setup .........[...]

  • Page 6

    Page 6 - 3400753300/AE 4. Maintenance 4.1 T roubleshooting .......................................................................................................................... 20 4.2 Replacement of the battery modules ........................................................................................ 22 5. Environment ...................[...]

  • Page 7

    P U L S A R w w w. m g e u p s . c o m 1 0 0 % 8 0 % 5 0 % 2 0 % t e s t % 1 2 % B Y P A S S E X 3400753300/AE - Page 7 Tower setup Rack setup 1.1 System configurations 1. Presentation w w w . m g e u p s . co m P U L S A R 3.75 inches (2U) 25.75 inches (EX 2200RT) 26.00 inches (EX 3200RT) 17.24 inches (19" Rack mount) 1 0 0 % 8 0 % 5 0 % 2 0 [...]

  • Page 8

    Page 8 - 3400753300/AE 4 6 12 11 10 9 8 7 1 3 2 4 12 11 10 9 8 7 5 3 2 1 15 14 15 14 13 12 Pulsar EXB 2200/3200 RT Pulsar EX 3200RT Pulsar EX 2200RT 11 10 8 9 7 6 5 4 3 2 1 Slot for communication-card option. RS232 communication port. USB communication port. Upper two receptacles for connection to AC-power source. Lower two programmable receptacles[...]

  • Page 9

    3400753300/AE - Page 9 27 26 25 24 23 22 21 20 19 18 17 16 (*) : ◗ flashing LED + buzzer: battery fault (battery must be replaced). ◗ flashing LED + long buzzer (once per hour): theoretical end of battery life (replacement recommended). UPS overload Electronics fault Battery fault * Site Wiring Fault 26 27 % load 100% 80% 50% 20% Press simultan[...]

  • Page 10

    Page 10 - 3400753300/AE 34 34 36 35 36 35 30 32 31 30 32 31 RS232 communication cable. USB communication cable. T elescopic rails for mounting in 19" bay with mounting hardware. CD-ROM with the Solution-Pac and UPS Driver software. Product documentation. T wo supports for the upright position. 2.1 Unpacking 2. Installation P U L S A R EX www.m[...]

  • Page 11

    3400753300/AE - Page 11 3 3 7 Stop-Notch Snap from inside of rails 2 6 4 5 5 2 1 CAUTION: Do not lean or place objects on top of unit at any time. Hazard of dismounting and disconnection can occur with units. NOTE: (For step 5) it is possible to adjust the position of the front fixing bracket. Follow steps A to D for rack mounting of the UPS on the[...]

  • Page 12

    Page 12 - 3400753300/AE Install the two supports for the upright position using provided hardware in the package. (see item 32 on page 10). Pull out the MGE Logo and Model plates, then rotate them as shown. 2. Installation 2.3 Installation in tower position P U L S A R P U L S A R www. mg e ups.com w w w .m geu ps . c o m 1 0 0 % 8 0 % 5 0 % 2 0 % [...]

  • Page 13

    3400753300/AE - Page 13 1 Slot for the communication card option. It is not necessary to shut down the UPS to install the communication card: 1. Remove the slot 1 cover secured by two screws. 2. Insert the card in the slot. 3. Secure the card with the two screws. 2.5 Installation of the communication-card option NOTE: The RS232 and USB communicatio[...]

  • Page 14

    Page 14 - 3400753300/AE 5 4 4 7 1. Connect the input power cord 7 to the AC-power wall-receptacle. 2. Connect the protected equipment to the UPS. It is advised to connect priority loads to the outlets and/or power cord 4 and any non-priority loads to the two programmable outlets 5 (If the UPS is connected to a computer running MGE UPS SYSTEMS, Inc.[...]

  • Page 15

    3400753300/AE - Page 15 27 26 25 18 17 16 24 20 19 21 22 23 27 26 25 18 17 16 Description of LED indicator status 20 and 21 for programmable outlets 1 and 2: ◗ OFF: the outlets are not supplied with power . ◗ Flashing: status change in progress. ◗ ON: the outlets are supplied with power . Outlets 1 and 2 can be remotely programmed and control[...]

  • Page 16

    Page 16 - 3400753300/AE 22 17 17 The UPS goes to sleep mode at the end of the battery backup time, until complete shutdown, due to tripping of the battery-protection function against deep discharge. Return of AC input power: IMPORT ANT : If, in spite of the return of AC input power, the UPS does not restart, check that the automatic-restart functio[...]

  • Page 17

    3400753300/AE - Page 17 "ON / OFF conditions" tab Options Once a day Once a month No test From 0% to 100% of the remaining battery backup time Disabled Default setting Every weeks 20% remaining battery backup time Enabled Personalization function Automatic "Battery test" intervals "Low-battery warning" threshold Protec[...]

  • Page 18

    Page 18 - 3400753300/AE 16 Press button 16 (return to the OFF position). The connected equipment is no longer supplied with power . 3.5 UPS shutdown "Bypass" tab "Output" tab Options Disabled (click to remove check) Enabled (click to add check) Default setting Enabled Disabled Personalization function T ransfer to bypass if over[...]

  • Page 19

    3400753300/AE - Page 19 38 37 12 1. Check that the UPS is shut off and disconnected from the AC power source. 2. Remove the RPO connector 12 by undoing the screws 37 . 3. Connect an insulated dry contact (NC, 60 V DC, 30 V AC max., 20 mA max., cable size 0.75 mm) to the two terminals of the RPO connector 38 . 4. Put the RPO connector 12 back in pla[...]

  • Page 20

    Indication Diagnostic Correction LED 27 flashes and UPS overload. Overload is too long or too high. ◗ Check the power drawn by the the buzzer beeps. ◗ If AC power is present and within tolerances, the equipment and disconnect any UPS goes to bypass mode (supply directly by the non-priority devices. AC-power source). LED 19 flashes. The buzzer b[...]

  • Page 21

    3400753300/AE - Page 21 Indication Signification Correction The outlets are not supplied One of the protection circuit breakers 6 for the ◗ Check that there is not a short- with power , even though outlets (on the back of the UPS) is open. circuit on the outlets. button 16 is ON ◗ Eliminate any overloads on the (3200 RT only). outlets by modify[...]

  • Page 22

    C D P U L S A R 1 0 0% 8 0% 5 0% 2 0 % t e st % 1 2 % B Y PA SS E X B A w w w . m ge u p s. c o m P U L S A R 1 0 0% 8 0 % 50 % 2 0 % t es t % 1 2 % B Y P A S S E X Page 22 - 3400753300/AE C - Remove the left part of the front panel. D - Disconnect the connector . A - Unclip the small plate with the MGE UPS SYSTEMS, Inc. Logo on the UPS front panel[...]

  • Page 23

    3400753300/AE - Page 23 G - Remove the two battery modules and proceed with replacement. Reinstallation of the battery module s To reinstall the battery modules perform this procedure in reverse order e.g., “G”, “F”, “E”. ◗ To maintain an identical level of performance and safety , use battery modules identical to that previously moun[...]

  • Page 24

    Page 24 - 3400753300/AE This product has been designed to respect the environment: It does not contain CFC's or HCFC's. UPS recycling at the end of service life: MGE UPS SYSTEMS, Inc. undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life[...]

  • Page 25

    Output power rating AC-input ◗ V oltage ◗ Frequency ◗ Power factor Output specification ◗ V oltage ◗ Frequency ◗ Harmonic distortion ◗ Overload capability Battery (sealed lead-acid, maintenance free) Environmental and safety ◗ Noise level ◗ Operating temperature ◗ Relative humidity ◗ Safety ◗ EMC ◗ Agency markings < 50 [...]

  • Page 26

    Page 26 - 3400753300/AE Authorized voltage range for Upper and lower voltage thresholds within which the UPS can operate on the automatic transfer to bypass if fault or bypass in the event of a UPS fault or overload. overload Automatic bypass Automatic switch controlled by the UPS, used to connect the equipment directly to the AC-power source in th[...]

  • Page 27

    3400753300/AE - Page 27 O ON LINE mode ..................................................................9 Overload ................................................................9-18-20 P Personalization ..............................................................17 Battery ....................................................................17 [...]

  • Page 28

    For service call: 1 800 523-0142 Internet: www .mgeups.com T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 3400753300-AE 1660 Scenic Avenue Costa Mesa, CA 92626, USA Main Number: 714 557-1636 MGE UPS SYSTEMS, INC. UPS SYSTEMS M G E[...]