Go to page of
Similar user manuals
-
Sphygmomanometer
Microlife Cardio+
23 pages -
Sphygmomanometer
Microlife BP A200 Afib
105 pages -
Sphygmomanometer
Microlife BP A2 Basic
21 pages -
Sphygmomanometer
Microlife BP 3AG1
105 pages -
Sphygmomanometer
Microlife BP A6 PC Afib
30 pages -
Sphygmomanometer
Microlife BP A1 Easy
86 pages -
Sphygmomanometer
Microlife AG1-20
28 pages -
Sphygmomanometer
Microlife BP AG1-40
30 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Microlife BP A2 Basic, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Microlife BP A2 Basic one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Microlife BP A2 Basic. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Microlife BP A2 Basic should contain:
- informations concerning technical data of Microlife BP A2 Basic
- name of the manufacturer and a year of construction of the Microlife BP A2 Basic item
- rules of operation, control and maintenance of the Microlife BP A2 Basic item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Microlife BP A2 Basic alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Microlife BP A2 Basic, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Microlife service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Microlife BP A2 Basic.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Microlife BP A2 Basic item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Microlife BP A2 Basic Europe / Middle-East / Africa Microlife AG Espenstrasse 139 9443 Widnau / Switzerland Tel. +41 / 71 727 70 30 Fax +41 / 71 727 70 39 Email admin@microlife.ch www.microlife.com Asia Microlife Corporation. 9F, 431, RuiGang Road, NeiHu Taipei, 11492, Taiwan, R.O.C. Tel. +886 2 8797-1288 Fax +886 2 8797-1283 Email service@microlif[...]
-
Page 2
Microlife BP A2 Basic BP A2 Basic A 2 S130 Guarantee Card Name of Purchaser Serial Number Date of Purchase Specialist Dealer BP W100 ١٢ AR ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ (ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ :يﺮﺘﺸﻤﻟا ﻢﺳا :ﻞﻳدﻮﻤﻟا :ﻞﺴﻠﺴﺘﻟا ﻢﻗر :ء?[...]
-
Page 3
1 BP A2 Basic EN Display Read the instructions carefully before using this devic e. Type BF applied part Dear Customer, Your new Microlife blood pre ssure monitor is a reliable medical device for taking measurements on the upper arm. It is simple to use, accurate and co mes highly recommended for blood pressure monitoring in your home. This device [...]
-
Page 4
2 Table of Contents 1. Important Facts about Blo od Pressure and Self-Measure- ment • How do I evaluate my blood pressure? 2. Usi ng the Devi ce for the Firs t Time • Inserting the batt eries • Setting the date and time • Selecting the correct cuff 3. Taking a Blood Pressure Measuremen t using this Device • How not to store a reading 4. A[...]
-
Page 5
3 BP A2 Basic EN How do I evaluate my blood press ure? The higher valu e is the one that d etermines the evaluation. Example: a blood pressure value of 140/80 mmHg or a value of 130/90 mmHg indicates «blood pressure too high». 2. Using the Device for the F irst Time Inserting the batteries After you have unpacked your de vice, first ins ert the b[...]
-
Page 6
4 9. During the measuremen t, the pulse in dicator AP flashes in the display. 10.The result, comprising the syst olic AL and the diastolic AM blood pressure and the pulse rate AN is displ ayed. 11.When the device has finish ed measuring, remove the cuff. 12.Switch off the device. (The monito r does switch off automati- cally after approx. 1 min.). [...]
-
Page 7
5 BP A2 Basic EN 1. Open the battery compartment 5 on th e bottom of the device. 2. Replace the batteries – ensure correct polarity as sho wn by the symbols in the compartment. 3. To set date and time, follow the procedure described in «Section 2.». The memory retains all values altho ugh date and time must be reset – the year number t he[...]
-
Page 8
6 • This device comprises sensit ive components and must be treated with caution. Observ e the storage and operatin g condi- tions described in the «Technical Spe cifications» section. • Protect it from: - water and moisture - extreme temperatures - impact and dropping - con taminati on and du st - direct sunlight - heat and cold • The cuff[...]
-
Page 9
7 BP A2 Basic EN[...]
-
Page 10
8 AR Microlife BP A2 Basic فﺎﻘﻳﻹا/ﻞﻴﻐﺸﺘﻟا رز 1 ضﺮﻌﻟا 2 قﻮﻄﻟا ﺲﺒﻘﻣ 3 ﻲﺋﺎﺑﺮﻬﻜﻟا ءﻰﻳﺎﻬﻤﻟا ﺲﺒﻘﻣ 4 ﺔﻳرﺎﻄﺒﻟا ةﺮﻴﺠﺣ 5 قﻮﻄﻟا 6 قﻮﻄﻟا ﻞ ّ ﺻﻮﻣ 7 ضﺮﻌﻟا ﺔﻴﺿﺎﺒﻘﻧﻻا ﺔﻤﻴﻘﻟا 8 ﺔﻴﻃﺎﺴﺒ[...]
-
Page 11
9 BP A2 Basic AR ΕΎϳϭΗΣϣϟϝϭΩΟ ϲΗΫϟαΎϳϘϟϭ ˷ ϡΩϟρϐοϝϭΣΔϣΎϫϕΎϘΣ˺ ˮϲ ˷ ϣΩρϐοϡ ˷ ϳϗϑϳϛ ϰϟϭϷΓέϣϠϟίΎϬΟϟϝΎϣόΗγ·˻ ΕΎϳέΎρΑϟϝΎΧΩ· ΕϗϭϟϭΦϳέΎΗϟΩΩϋ· ?[...]
-
Page 12
10 ϲϓϡΩΧΗγϼϟιΎΧϝϛηΑϲϟΎΣϟϡΩϟρϐοΔΑϗέϣίΎϬΟέΎΑΗΧϡΗ % ϰϠϋΔόϔΗέϣΕ˯έϗϑΎηΗϛΔϟΎΣϲϓϝϣΣϟϡϣγΗϭϝϣΣϟΕϻΎΣ ϊΑέΩόΑϯέΧΓέϣΓ˯έϘϟΫΧϲϐΑϧϳϓ[...]
-
Page 13
11 BP A2 Basic AR νϔΧϧϳϭ ˷ Φοϟϑ ˷ ϗϭΗϳˬϳΣλϟϯϭΗγϣϟϰϟ·ρϐοϟϝλϳΎϣΩϧϋ ́ ˬΏϭϠρϣϟρϐοϟϰϟ·ϝϭλϭϟϡΗϳϡϟΫ·ϲΟϳέΩΗϝϛηΑρϐοϟ ωέΫϟϡίΣϲϓΎϳϟέΛϛ˯ϭϫί?[...]
-
Page 14
12 ΦϳέΎΗϟϥϳϳόΗΓΩΎϋ·ϰϟ·ΔΟΎΣϟϥϣϡϏέϟΎΑϡϳϘϟΔϓΎϛΑΓέϛΫϟυϔΗΣΗ % ϝΩΑΗγΩόΑϙϟΫϰϠϋ ˱ ˯ΎϧΑΎ ˱ ϳΎϘϠΗΔϧγϟϡϗένϣϭϳΙϳΣ±Εϗϭϟϭ ΕΎϳέΎρΑϟ ˮ˯έΟ· ˷ ϱϭΕ[...]
-
Page 15
13 BP A2 Basic AR ΔϟΎϔϛϟ ˺˺ ΔϳέΎγϲϫϭ˯έηϟΦϳέΎΗϥϣ Εϭϧγ˾ΓΩϣϟΔϟΎϔϛΑ ϰρϐϣίΎϬΟϟΫϫ ˷ ϥ· ϲΗϟϭϪϔϠΧέυϧΎϬΗΎϧΎϳΑωίϭϣϟϝϣϛΗγϲΗϟΔϟΎϔϛϟΔϗΎρΑϡϳΩϘΗΩϧ?[...]
-
Page 16
14 FA Microlife BP A2 Basic فﺎﻘﻳﻹا/ﻞﻴﻐﺸﺘﻟا رز 1 ضﺮﻌﻟا 2 قﻮﻄﻟا ﺲﺒﻘﻣ 3 ﻲﺋﺎﺑﺮﻬﻜﻟا ءﻰﻳﺎﻬﻤﻟا ﺲﺒﻘﻣ 4 ﺔﻳرﺎﻄﺒﻟا ةﺮﻴﺠﺣ 5 قﻮﻄﻟا 6 قﻮﻄﻟا ﻞ ّ ﺻﻮﻣ 7 ضﺮﻌﻟا ﺔﻴﺿﺎﺒﻘﻧﻻا ﺔﻤﻴﻘﻟا 8 ﺔﻴﻃﺎﺴ?[...]
-
Page 17
15 BP A2 Basic FA ΕγέϬϓ έΎϣϳΑΩϭΧργϭΗϥ̵έϳ̳ϩίΩϧϭϥϭΧέΎηϓϩέΎΑέΩϡϬϣΕΎ̰ϧ ˺ ˮϡϧ̶̯ΑΎϳίέέΩϭΧϥϭΧέΎηϓϪϧϭ̴̩ έΎΑϥϳϟϭ̵έΑϩΎ̴ΗγΩίϩΩΎϔΗγ ˻ Ύϫ̵έΗΎΑ̵έ?[...]
-
Page 18
16 ϥέϭΩΕϳϣϭ ϣ γϣϝέΗϧ ̯ϭ ̵έΩέΎ ΑϥέϭΩ έΩΩέΑέΎ ̯ ̵έ Α ϩΎ̴ Η γΩϥϳ ( ϥΩϭ ΑϻΎΑ ιϳ Χ ηΗΕέϭλέΩ Ε γϪΗϓέ ̳ έέϗεϳΎ ϣίΩέϭϣ ̵έΩέΎΑ ί α ̡ ˱ ΩΩΟ ϣέ ΩϭΧ[...]
-
Page 19
17 BP A2 Basic FA έ̴ηϳΎϣϧϪΣϔλέΩϥϭΧέΎηϓέρΧϥίϳϣΩΎϣϧ ̋ ΎϣηϪΑ ⑮ ϥϭΧέΎηϓέρΧϥίϳϣεϳΎϣϧ̟̩Εϣ γϪΑϟέΩΩϭΟϭϣ̵Ύϫέϭϧ ̵ΩϧϠΑ ϪΑ ϪΗγΑ ΩέΩ έέϗ ̶Σργ Ϫ̩ έΩ ?[...]
-
Page 20
18 νϳϭόΗ±̵έΗΎΑϡΎϣΗ ϥΩέ̯ϥηϭέία̡ ⑩ ̶ϟΎΧ̵έΗΎΑΩΎϣϧ̵έΗΎΑϥΩϭΑ̶ϟΎΧΕέϭλέΩ ϥϳέΩ̶ϟΎΧ ˱ ϼϣΎ̵̯έΗΎΑεϳΎϣϧΩϧ̶̯ϣϥΩί̮ϣη̩ϪΑωϭέηϩΎ̴ΗγΩ Ωϧϭηνϳϭό[...]
-
Page 21
19 BP A2 Basic FA ΩέϭϣρΎϳΗΣΎΑΩϳΎΑϭϩΩηϝϳ̰ηΗαΎγΣέΎϳγΑ̵ίΟίϩΎ̴ΗγΩϥϳ ΕΎλΧηϣ » εΧΑέΩέΩέ̰Ϡϣϋϭ̵έΩϬ̴ϧρϳέηΩέϳ̳έέϗϩΩΎϔΗγ ΩϳϳΎϣϧϩΩϫΎηϣ « ̶ϧϓ Ω[...]