Go to page of
Similar user manuals
-
Switch
MicroNet Technology SP616R
14 pages 0.36 mb -
Switch
MicroNet Technology SP3508A
52 pages 2.76 mb -
Switch
MicroNet Technology SP218D
24 pages 0.68 mb -
Switch
MicroNet Technology SP616EB
7 pages 0.19 mb -
Switch
MicroNet Technology SP624R
7 pages 0.17 mb -
Switch
MicroNet Technology SP648B
33 pages 1.67 mb -
Switch
MicroNet Technology SP616DB
12 pages 0.54 mb -
Switch
MicroNet Technology SP624DB
12 pages 0.54 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of MicroNet Technology SP624DB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MicroNet Technology SP624DB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of MicroNet Technology SP624DB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of MicroNet Technology SP624DB should contain:
- informations concerning technical data of MicroNet Technology SP624DB
- name of the manufacturer and a year of construction of the MicroNet Technology SP624DB item
- rules of operation, control and maintenance of the MicroNet Technology SP624DB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MicroNet Technology SP624DB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MicroNet Technology SP624DB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MicroNet Technology service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MicroNet Technology SP624DB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the MicroNet Technology SP624DB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User ’s Manu al EtherFast 10/100M Smart Switch Model No.: SP616DB / SP624DB http://www .micronet.info[...]
-
Page 2
Package Contents V erify y our package contain s the following items: z SP616DB/SP624DB 10/1 00 Mb ps Smart Switch z User’s Manual z Power Cord z Rack Ears with Screws and Rubber Foots Features Micronet SP616DB/SP624DB has the follow ing key features: z Provide 16 (SP616DB) or 24 (SP624DB) RJ-4 5 port s of 10/100 Mbps, auto negotiation z Provide [...]
-
Page 3
3 POWER This LED comes on w hen the sw itch is properly connected to power and turned on. TX/FX Push Button The push button is located at the right side of port 16 (SP616DB) or port 24 (SP624DB). Release this button to use RJ-45 port 16 (S P616DB) or port 24 (SP624DB), an d press this button to use the 100BASE-FX module. IP RESET Push Butto n Press[...]
-
Page 4
Installation Preparing the Site Select the site that meet s the following require m ent s: Characteristic Requirement Temperature 32 to 104 ˚ F (0 to 40 ˚ C) Humidity Maximum relative humidity of 90%, non-condensing Condition At least 1.8 meters (6 feet) to the nearest source of electromagnetic noise Ventilation Minimum 3 inches (0.25 feet) of cl[...]
-
Page 5
5 Step 2: Remove the module from the static-free container. Step 3: Unscrew the cover pl ate of the expansion slot. (The slot for single-port module is loca ted at the right side of the switch.) Step 4: Remove the plate. (Keep it for future use in case you decide to remove this module later.) Step 5: Carefully slide the module into the slot, along [...]
-
Page 6
Switch Configuration Setting UP Console Port Connection SP616DB/SP624DB provide s o ne RJ-45 console port and a web-based interface, allow ing user s to configure and manage the switch remotely from web browser. 1. Connect UTP/STP cable to SP616DB/SP624DB’s con sole port. Figure 5: Connect directly to PC Figure 6: Connect to PC via another switch[...]
-
Page 7
Figure 8: Main menu System Change The System Change p arameters can be display ed by clicking the System Chan ge button in the left sub-menu. Figure 9: System Change z Switch Name: T ype a switch name and replace the current sw itch name with a new one. (Please rest art your Comput er once the Switch Name is replaced a nd saved under “Save Config[...]
-
Page 8
IP Configuration Figure 10: IP Configuratio n z Refresh: Click the Refresh button and refresh back to the last saved IP Configurations. z IP Address, Netmask, Default Gateway: Y o u can see and change the IP Address, Netmask, and Default Gateway of the Ethernet Switch. z Apply: Click the Apply button and apply the new IP Configurations. Port Figure[...]
-
Page 9
VLAN Figure 12: VLAN z VLAN: Click and choose the port s to be added into the VLAN gr oups. z Apply: Click the Apply button and apply the new settings of the VLAN groups. Note: all Ports h ave to be selected to one of the VLAN Groups, those Port/Port s were not selected will be notified by the alarm mess age w hich shows “Non-Identify VLAN Group [...]
-
Page 10
T runk SP616DB: Figure 13: T runk of SP616DB z Disable: Click and choose the Disable to disable the Trunk Group 1 or T runk Group 2. z T runk Group 1: Click and choose the Port 1, 2 to be added into the T runk Group 1. z T runk Group 2: Click and choose the Port 9, 10 to be added into the T runk Group 2. z Apply: Click the Apply button and apply th[...]
-
Page 11
Save Configuration Figure 15: Save Configuration z Click Save Configuration . z Click the Ok or Cancel button to or not to save the configurations. Note: the Cancel button will discard any dat a you have changed since the last "Save" operation. Without clicking Ok button, the switch does not save any changes you may have made. Load Defaul[...]
-
Page 12
Specifica tions IEEE standard IEEE 802.3,10BaseT IEEE 802.3u,100BaseTX/FX Port SP616DB: 16 10/100 Mbps ports SP624DB: 24 10/100 Mbps ports Speed 200 Mbps full-duplex 100 Mbps half-duplex Dimension 440 × 207 × 44 mm rack-mount size Weight SP616DB: 1.94 kg SP624DB: 2.07 kg Power Input 100 - 240 VAC, 50 - 60 Hz Input Fuse SP616DB: 3.3VDC, 2.5A SP624[...]