Go to page of
Similar user manuals
-
Ventilation Hood
Miele 09 730 840
48 pages 2.64 mb -
Ventilation Hood
Miele DA270
36 pages 0.59 mb -
Ventilation Hood
Miele DA 220-4
40 pages 0.93 mb -
Ventilation Hood
Miele HS60CIX1
12 pages 1.02 mb -
Ventilation Hood
Miele DA 399-5
36 pages 1.01 mb -
Ventilation Hood
Miele DA2900EXT
40 pages 1.31 mb -
Ventilation Hood
Miele DA 406
40 pages 1.4 mb -
Ventilation Hood
Miele 09 813 750
60 pages 2.95 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Miele DA220-3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Miele DA220-3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Miele DA220-3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Miele DA220-3 should contain:
- informations concerning technical data of Miele DA220-3
- name of the manufacturer and a year of construction of the Miele DA220-3 item
- rules of operation, control and maintenance of the Miele DA220-3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Miele DA220-3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Miele DA220-3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Miele service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Miele DA220-3.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Miele DA220-3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operating and Installation Instr uctions V entilation System D A 220-3 T o pr event accidents and machine damage, read these instructions before installation or use. UV M.-Nr . 06 438 010[...]
-
Page 2
IMPORT ANT SAFETY INSTR UCTIONS Functional description Guide to the appliance Operation T urning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Selecting the power level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Delayed Shut Down . . . [...]
-
Page 3
Read these Operating Instructions carefully bef ore installing or using the V entilation System. This appliance is intended for residential use only . Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood. This appliance complies with current safety requir ements.[...]
-
Page 4
This equipment is not designed for maritime use or for use in mobile installations such as caravans or aircraft. However , under certain conditions it may be possible for an installation in these applications. Please contact the nearest Miele dealer or the T echnical Service Department with specific requir ements. Before servicing or cleaning the u[...]
-
Page 5
, W ARNING - T O REDUCE THE RISK OF A RANGE T OP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. Always turn the hood “ON” when cooking at high heat or when cooking flaming foods. Clean ventilating fans frequently . Grease s[...]
-
Page 6
Installation , W ARNING T o reduce the risk of fire only use metal ductwork. When installing the hood, follow the recommended minimum safety distances between a Miele cooktop and the hood: – 22" (55 cm) above electric cooktops, – 26" (65 cm) above gas cooktops, – 26" (65 cm) above an open grill. If local building codes requir e[...]
-
Page 7
The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a non-return flap . This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur . When the hood is turned on, the air pressure of the exhaust [...]
-
Page 8
Guide to the appliance 8[...]
-
Page 9
a Cover plate b Chimney c Canopy d Grease filters e Control panel f Overhead lighting g Light button This button turns the light on and off and also dims the light. The lighting can be used independently of the fan. h On/Off button i Fan po wer level b uttons Four fan speed selection. j Delay ed Shut Down This button activates the Delayed Shut Down[...]
-
Page 10
T urning on the fan ^ Press the On/Of f button. The fan runs at power level "2". The On/Off indicator lights. Selecting the power le vel ^ Use the _ buttons to select the desired power level. & =increases the fan speed $ =decreases the fan speed Level "1" to "3" (green indicators) ar e usually sufficient for normal[...]
-
Page 11
T urning off the fan ^ Press the On/Of f button to turn the fan off. The indicator goes out. A utomatic Safety Shut Off The fan will turn off automatically 10 hours after the last button was activated. The lighting however will remain on. ^ Press the On/Of f button to turn the fan back on again. T urning the lighting on/off The overhead lighting ca[...]
-
Page 12
Grease filter timer A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filters must then be cleaned. After the grease filters have been cleaned and put in place, the grease filter timer must be reset. ^ T o do this, press the gr ease filter button for about 3 seconds. [...]
-
Page 13
Reprogramming the grease filter timer The grease filter timer is pr eset to 30 hours. This time can be lengthened or shortened to 20, 30, 40 or 50 hours. – A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. – A time of 20 hours should also be programmed if the kitchen is only used occasionally . Otherwise grea[...]
-
Page 14
Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet or manually "tripping" the circuit breaker . Cleaning the casing , Never use abrasive cleaners, scouring pads, steel wool, thinner or caustic (oven) cleaners on the hood. They will damage the surface. ^ All[...]
-
Page 15
Grease filters The reusable metal gr ease filters remove solid particles from the vented kitchen air (grease, dust, etc). The grease filters should be cleaned every 3-4 weeks or whenever the grease filter timer indicator lights. A dirty filter is a fire hazard. ^ T o remove the gr ease filters press the locking clips in towards the middle of the fi[...]
-
Page 16
Changing the light bulb Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit br eaker . When in use halogen bulbs become extremely hot, and they can burn your hands. Do not attempt to change the bulbs until they have had sufficient time to[...]
-
Page 17
In the event of a fault which you can not correct yourself please contact the Miele T echnical Service Department U 1-800-999-1360 techserv@mieleusa.com V 1-800-565-6435 service@miele.ca When contacting the T echnical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible w[...]
-
Page 18
18[...]
-
Page 19
Installation Instr uctions[...]
-
Page 20
The ceiling mounting plate will support the weight of the hood. This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists, or to the ceiling joists directly . Do not attach the plate directly to the ceiling by using anchors, mollies or toggle bolts. Structural suppor t 20[...]
-
Page 21
All electrical work should be perfor med by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufactur er can not be held responsible for unauthorized work. Ensure that power to the appliance is OFF while installation or repa[...]
-
Page 22
a Mounting bolt holes b Alternative positions for feeding through the power cord c Exhaust connection 6" (150 mm) diameter Appliance dimensions 22[...]
-
Page 23
Do not install this exhaust hood over cooktops burning solid fuel. When installing the hood, make sure that the following minimum distance ( S ) between the top of a Miele cooking surface and the bottom of the hood is: - 22" (55 cm) above electric cooktops - 26" (65 cm) above gas cooktops - 26" (65 cm) above an open grill For non-Mie[...]
-
Page 24
^ Cut a 7 1 / 2 " (190 mm) hole in the ceiling centered over the cooktop for the exhaust duct to pass through. The exhaust connection has a 6" (150 mm) diameter . ^ Hold the mounting plate up to the ceiling so that the orange arrow faces the front of the hood and aligns with the line drawn on the ceilling. ^ Mark the position of the four [...]
-
Page 25
^ Feed the ductwork and power cable through their r espective holes in the ceiling. If 6" (150 mm) ductwork is not possible then 5" (125 mm) ductwork can be used in conjunction with a reducing collar available from the Miele T echnical Service Department (see "Installation / Air extraction" for further details). ^ Drill four 3 /[...]
-
Page 26
^ Insert the shor t edge of the two spring clips into their slots from below and pivot them 90° so that the tab faces the center of the mounting brake. ^ Pull the power cord thr ough the mounting plate. ^ Insert the four countersunk screws M 6 x 20 into the recessed holes fr om above. ^ T ape the screws fr om above to prevent them fr om being push[...]
-
Page 27
^ Using at least two people, lift the hood and guide the spring clips through their r espective slots in the flange at the top of the chimney . Make sure they click into place and that the hood is hanging securely fr om the spring clips before allowing them to carry the weight. ^ Bolt the flange firmly to the ceiling using the four M6 nuts. ^ Short[...]
-
Page 28
^ Finally , being careful not to scratch the chimney , push the cover plate upwards until the spring fixing clips click into place. If installed correctly , the cover should be secure and flush against the ceiling. ^ Before using the appliance r emove the grease filter and r emove the protective foil fr om the filter frame. Return filter . Installa[...]
-
Page 29
Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. The exhaust gases extracted b y the hood should be vented outside of the building onl y . Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc. Please read and follow the "Important Safety Instructions" to redu[...]
-
Page 30
If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney , dryer vent, vent flue, or room venting ductwork. Seek professional advice befor e connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important! If the d[...]
-
Page 31
Disposal of packing material The cardboar d box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. T o prevent suf focation of children, ensure that any plastic wrappings, bags etc. are disposed of safely and kept out of their reach. Disposal of an old appliance O[...]
-
Page 32
M.-Nr . 06 438 010 / 00 Alteration rights reserved / 4304[...]