Go to page of
Similar user manuals
-
Switch
Milan Technology MIL-SME801GLX
155 pages 1.68 mb -
Switch
Milan Technology MIL-S3570
23 pages 1.04 mb -
Switch
Milan Technology MIL-S8000T
13 pages 0.16 mb -
Switch
Milan Technology MIL-S501SC-40
20 pages 0.75 mb -
Switch
Milan Technology MIL-SM8002TG
180 pages 3.04 mb -
Switch
Milan Technology CERTXFX01
4 pages 0.09 mb -
Switch
Milan Technology MIL-S801XX
14 pages 0.41 mb -
Switch
Milan Technology MIL-SM2401M
132 pages 4.39 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Milan Technology MIL-L800i, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Milan Technology MIL-L800i one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Milan Technology MIL-L800i. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Milan Technology MIL-L800i should contain:
- informations concerning technical data of Milan Technology MIL-L800i
- name of the manufacturer and a year of construction of the Milan Technology MIL-L800i item
- rules of operation, control and maintenance of the Milan Technology MIL-L800i item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Milan Technology MIL-L800i alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Milan Technology MIL-L800i, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Milan Technology service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Milan Technology MIL-L800i.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Milan Technology MIL-L800i item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MIL-L800i 8-Port Power over Ethernet Injector Hub USER GUIDE[...]
-
Page 2
Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A - EN55024 Canadian EMI Notice This Class A digital apparatus meets all the requirements of the Canadian Interferenc e-Causing Equipment Regulations. Cet appareil numerique de la classe A respecte toutes les ex igences du Reglement sur le ma teriel broui[...]
-
Page 3
Table of Contents 1. Introduc tion ............................................................................................................. 1 Featur es .................................................................................................................... 1 Package Cont ents ........................................................[...]
-
Page 4
1 1. Introduction Thank you for purchasi ng MiLAN Technology’s Em Powered TM Series 8-port Power over Ethernet Injector Hub. Power-over-Ethernet (PoE) eliminates the need to run 110/220 VAC power to other devices on a wired LAN. Using Power-over-Ethernet, system installers need to run only a single CAT5 Et hernet cable that carr ies both power an[...]
-
Page 5
2 Auto detect PD and classificati on of power consumption level Supports manual control of port power detection and classification Support automatic system calibration Support Auto MDI/MDI-X depends on the uplink switch port Centralized power distribution for PoE powered Device (PD) High safety short circuit prot ection to p[...]
-
Page 6
3 2. Hardware Description This Section describes the hardware of the 8 port Power over Ethernet Hub, and gives a physical and functional overview. Physical Dimensions The MIL-L800i PoE Injector Hub’s physical dimension is: 440mm x 224mm x 44mm (Lx W x H) F r o n t P a n e l The Front Panel of the MIL-L800i PoE Injector Hub consists of 16x RJ-45 E[...]
-
Page 7
4 L E D I n d i c a t o r s The LED Indicators gives real-time informa tion of systematic o peration status. The following table provides descriptions of LED status and their meaning. Figure 2-2. LED indicators LED Status Color Description On Green Power is transmitting to the device Power Forwarding Off -- Power is not transmitting to the device O[...]
-
Page 8
5 Figure 2-3 Rear panel of the 8 port Power over Ethernet Hub P o w e r O n Connect the power cord to the power socket on the rear panel of the Switch. The other side of power cord connects to the power outlet. The internal power supply of the Switch works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check the power indicator on t[...]
-
Page 9
6 Po w e r e d D e vi c e , e x: SOH O s w it c h o r W ir e le s s A P 123456 789 1 0 1 1 1 2 A B 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x Ethernet A 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x C 123456 789 1 0 1 1 1 2 A B 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x Ethernet A 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x C POWER FAULT DAT A ALARM Co r e S w it c h [...]
-
Page 10
7 3. Software Utility Installation Berfore you start to remote configuring PD, pl ease intsall the software utility. Through the software utility, you can easily to controll t he PD that connect with PoE and view the PD parameter informations. The so ftware utility provides GUI in terface and user can easily to start with it. The software utility s[...]
-
Page 11
8 5. Click the button to start installation. See Figure 3-2. Figure 3-2[...]
-
Page 12
9 6. When installation finishes, click “O K” button to finish. See Figure 3-3. Figure 3-3 7. To run the software utility, go to “ Star ” Æ “ Program ” Æ “ Power Over Ethernet series ”. 8. If you want to remove the software utility, go to “ Star ” Æ “ Control Panel ” Æ “ Remove/ Add application ” Æ “ Power Over Eth[...]
-
Page 13
10 4. GUI Management C o n n e c t i n g t o P o E Connecting the PoE with PC through the cons ole port. Then, connect the PD (Powered Device) to the port of PoE. Run the softw are utility and select the COM port form Serial Link Setup function. You will see the main utility interface as figure 4-1. Figure 4-1. The GUI ma nagement interface The GUI[...]
-
Page 14
11 Device Setting: you can save the device confi guration to system, down load the device current configuration to the ut ility system and enable auto refresh function. Port Specific Control: each port specific function control and relate parameters display. Parametric Information: port parameters information di splay. System Setup &[...]
-
Page 15
12 System Information Chip Version: display the system chipset version and revision information. Firmware Version: display the system firmware version. Utility Version: display the system utility version Total Port Power (W): total of all the port power that the system provided to PD. Figure 4-3. System Information interface[...]
-
Page 16
13 Device Setting Enable Auto-Refresh: It allows the system auto re fresh the system parameters. The system auto refresh in every 2 seconds. Load f r om Dev i ce : To get the last configuration value from device to the system utility. S a v e to D e vi c e : When you have configured the System Setup & Control and Port Specific Contr[...]
-
Page 17
14 Port Specific Control Port Enable: enabling the port. This function is co-responding with “Master Enable” function. Bypass Detection: bypass the detection function. Normally the system will try to detect the 25k Ω resistor in an 802.3af compliant PD device. If the PD doesn’t follow by IEEE 802.3af standard, you can enable th is o[...]
-
Page 18
15 LED Status Indicators: current LED indicator display – green, yellow, and red. The LED indicator will change depends on the PD status. ¾ Green: It represents PD is connecting with the POE hub syst em and working normally. ¾ Yellow: It represents there is no PD connecting with the port. ¾ RED: It represents PD’s power request is over t[...]
-
Page 19
16 Figure 4-5. Port Specific Control interface[...]
-
Page 20
17 Parametric Information Discovery R (ohms): display resistance value. Port Current (mA): display current value. Port Voltage (V): display voltage value. Port Power (W): display watt value. Class Current (mA): display class current value. When you enable the “Bypass classification” function, the class current va lue will no[...]
-
Page 21
18 5. Technical Specification St andards IEEE802.3af Power over Ethernet IEEE802.3 10Base-T, IEEE 802.3u 100Base-TX Connector Data in: 8 x RJ-45, Data pin 1,2,3,6 Data and power out: 8 x RJ-45. Data pin 1,2,3,6 Power pin (V+): 4, 5, Power pin (V-): 7,8 Power out put Per port DC 48V@350mA (Maximum), Per system 125Watts (maximum) Management Microsoft[...]
-
Page 22
19 Fault status detect Null: no PD present or PD status is normal Overload: current support over 475mA @ DC 48V and over 50 milliseconds Mode status System detects status – I- sample, V-sample and R-detect Parametric information It will show current PD parameters which include Discover-resistor detected value, current, voltage, power consumption,[...]
-
Page 23
20 6. Appendix Console Port Pin Assignments The female DB-9 serial port on the POE hub front panel is used to connect to the switch for out-of-band console configur ation. The web interface c onfiguration program can be accessed from PC running the system utilit y program. The pin assignments used to connect to the serial port are pr ovided in the [...]
-
Page 24
21 DB-9 Port Pin Assignments EIA Circuit CCITT Signal Description Swit ch’s DB9 DTE Pin # PC DB9 DTE Pin # BB 104 RxD (Received Data) 2 2 BA 103 TxD (Transmitted Data) 3 3 AB 102 SGND (Signal Ground) 5 5 NOTE: Remaining pins are not used. Console Port to 9-Pin DTE Port on PC Switch’s 9-Pin Serial Port CCITT Signal PC’s 9-Pin DTE Port 2 RXD &l[...]
-
Page 25
90000429 Rev 1P[...]